Sequential analysis of multiple analytes using a surface plasmon resonance (SPR) biosensor.

A sequential analysis method for the analysis of two analytes was developed using a surface plasmon resonance (SPR) biosensor. A sample with both analytes was introduced into the single sensing region and then each analyte was analyzed sequentially. Two detection models were devised for the samples with the following composition: (1) one target analyte resulting in a sensor response without any label and the other analyte with only additional label, (2) both target analytes requiring additional labels for detection. A standard curve for each model was prepared and applied for sequential analysis of anti-bovine serum albumin (anti-BSA) antibodies and horseradish peroxidase (HRP). The errors of the sequential analysis of Models 1 and 2 were found to be less than 6%, and this method was therefore acceptable for application. No cross-reaction arising from non-specific binding among the participating antigens and antibodies was shown to occur in Models 1 and 2. For optimization of the analyte binding capacity of immunoaffinity (IA), the concentration ratio of the molecular recognition element at the immobilization step was adjusted. Subsequently, from the measurement of the maximum sensor response (R(max)), optimization of the analyte binding capacity could be made. Using Model 2, the feasibility of sequential analysis was demonstrated by detecting levels of human chorionic gonadotropin (hCG) and human albumin (hA) in healthy human urine, since both proteins are known to be related to abortion and preterm delivery during early pregnancy.

[1]  W. Heineman,et al.  Simultaneous immunoassay using electrochemical detection of metal ion labels. , 1994, Analytical chemistry.

[2]  Sung Min Cho,et al.  Characterization of a self-assembled monolayer of thiol on a gold surface and the fabrication of a biosensor chip based on surface plasmon resonance for detecting anti-GAD antibody. , 2005, Biosensors & bioelectronics.

[3]  Kim Pettersson,et al.  Double-label time-resolved immunofluorometry of lutropin and follitropin in serum. , 1987, Clinical chemistry.

[4]  A. Ellington,et al.  Simultaneous detection of diverse analytes with an aptazyme ligase array. , 2003, Analytical biochemistry.

[5]  S. Gutcho,et al.  Simultaneous radioassay of serum vitamin B12 and folic acid. , 1977, Clinical chemistry.

[6]  D. Wild The Immunoassay Handbook , 2001 .

[7]  R. Canfield,et al.  Convenient radioimmunoassay for urinary human choriogonadotropin without interference by urinary human lutropin. , 1981, Clinical chemistry.

[8]  J. Pyun,et al.  Application of SPR biosensor for medical diagnostics of human hepatitis B virus (hHBV) , 2005 .

[9]  C. Jung,et al.  Development of a surface plasmon resonance sensor for commercial applications , 1997 .

[10]  K. Nustad,et al.  Dual analyte assay based on particle types of different size measured by flow cytometry. , 1995, Journal of immunological methods.

[11]  Jan Greve,et al.  Surface Plasmon Resonance Multisensing , 1998 .

[12]  Niklas Larsson,et al.  Simultaneous monitoring of glucose and l-lactic acid during a fermentation process in an aqueous two-phase system by on-line FIA with microdialysis sampling and dual biosensor detection , 1998 .

[13]  E. Kretschmann,et al.  Notizen: Radiative Decay of Non Radiative Surface Plasmons Excited by Light , 1968 .

[14]  I. Brooks,et al.  Determination of rate and equilibrium binding constants for macromolecular interactions using surface plasmon resonance: use of nonlinear least squares analysis methods. , 1993, Analytical biochemistry.

[15]  J. Bridges,et al.  Simultaneous enzyme immunoassay of two thyroid hormones. , 1982, Clinical chemistry.

[16]  Chris A. Rowe-Taitt,et al.  Simultaneous detection of six biohazardous agents using a planar waveguide array biosensor. , 2000, Biosensors & bioelectronics.

[17]  C. R. Morgan,et al.  Immunoassay of Human Insulin and Growth Hormone Simultaneously Using 1-131 and 1-125 Tracers.∗ , 1966, Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine.

[18]  Jeong-Woo Choi,et al.  Optical biosensor for simultaneous detection of captan and organophosphorus compounds. , 2003, Biosensors & bioelectronics.

[19]  R E Kunz,et al.  Single-pad scheme for integrated optical fluorescence sensing. , 2000, Biosensors & bioelectronics.

[20]  Min-Gon Kim,et al.  Enhanced sensitivity of surface plasmon resonance (SPR) immunoassays using a peroxidase-catalyzed precipitation reaction and its application to a protein microarray. , 2005, Journal of immunological methods.

[21]  Timothy M. Chinowsky,et al.  Performance of the Spreeta 2000 integrated surface plasmon resonance affinity sensor , 2003 .

[22]  F. Ligler,et al.  Detection of multiple toxic agents using a planar array immunosensor. , 1998, Biosensors & bioelectronics.

[23]  Tuan Vo-Dinh,et al.  Simultaneous detection of the tumor suppressor FHIT gene and protein using the multi-functional biochip. , 2002, Cancer detection and prevention.

[24]  Hywel Morgan,et al.  Simultaneous determination of follicle stimulating hormone and luteinising hormone using a multianalyte immunosensor , 1995 .

[25]  R. Colton,et al.  The BARC biosensor applied to the detection of biological warfare agents. , 2000, Biosensors & bioelectronics.

[26]  P. Damm,et al.  Pregnancy outcome in type 1 diabetic women with microalbuminuria. , 2001, Diabetes care.

[27]  Christopher T. Elliott,et al.  On-line detection of sulfamethazine and sulfadiazine in porcine bile using a multi-channel high-throughput SPR biosensor , 2002 .

[28]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[29]  Clement E. Furlong,et al.  A commercial solution for surface plasmon sensing , 1996 .

[30]  R. Karlsson,et al.  Biospecific interaction analysis using surface plasmon resonance detection applied to kinetic, binding site and concentration analysis. , 1992, Journal of chromatography.

[31]  H. Aboul‐Enein,et al.  Amperometric biosensors/sequential injection analysis system for simultaneous determination of S- and R-captopril. , 2000, Biosensors & bioelectronics.

[32]  Michael S Wilson,et al.  Electrochemical immunosensors for the simultaneous detection of two tumor markers. , 2005, Analytical chemistry.

[33]  H. Weetall,et al.  The sixth international meeting on chemical sensors , 1996 .

[34]  Jose Melendez,et al.  Detection of Staphylococcus aureus enterotoxin B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor. , 2002, Biosensors & bioelectronics.

[35]  U. Narang,et al.  Multianalyte detection using a capillary-based flow immunosensor. , 1998, Analytical biochemistry.

[36]  S. Hadfield,et al.  A novel coloured latex test for the detection and identification of more than one antigen. , 1987, Journal of immunological methods.

[37]  A. Otto Excitation of nonradiative surface plasma waves in silver by the method of frustrated total reflection , 1968 .

[38]  Bonnie J. Tyler,et al.  Comparison of the Spreeta® surface plasmon resonance sensor and a quartz crystal microbalance for detection of Escherichia coli heat-labile enterotoxin , 2001 .

[39]  J. Katzmann,et al.  Simultaneous measurement of total and IgA-conjugated alpha 1-microglobulin by a combined immunoenzyme/immunoradiometric assay technique. , 1989, Clinical chemistry.

[40]  B. Liedberg,et al.  Surface plasmon resonance for gas detection and biosensing , 1983 .

[41]  Rolf D. Schmid,et al.  A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution , 1999 .

[42]  Anthony J. Strong,et al.  On-line monitoring in neurointensive care: enzyme-based electrochemical assay for simultaneous, continuous monitoring of glucose and lactate from critical care patients , 2002 .