Modified conduit preparation creates a pseudosinus in an aortic valve-sparing procedure for aneurysm of the ascending aorta.

Mechanical valved conduit replacement of the aortic root is a durable and appropriate procedure for many diseases of the ascending aorta, but may sacrifice an anatomically salvageable aortic valve. For young active patients and for patients with "systemic" arterial disease (atherosclerosis, Marfan's syndrome) who may require future operations, life-long anticoagulation with its attendant thromboembolic versus hemorrhagic risks is not ideal. Several techniques have been suggested as aortic valve-sparing options. Recently, a procedure was described that combines the freehand homograft techniques with the standard Bentall techniques (David procedure). This innovative technique replaces the ascending aorta with a Dacron cylinder, spares the aortic valve, and restores competence and thus offers an excellent alternative. The durability of this procedure that places the aortic valve inside a cylindrical conduit without sinuses of Valsalva is unknown. In selected patients, we have used this technique to spare the aortic valve. On the basis of experimental data and preliminary computer modeling, with the hope of improving the durability, we have modified the conduit to create a "pseudosinus" in our most recent nine patients. We have done the David procedure in 10 patients. The pseudosinus modification was done in the most recent nine patients. Patients' ages ranged from 37 to 71 years (mean 49.9 years). There were five female and five male patients. Five patients had Marfan's syndrome and five patients had annuloaortic ectasia. There has been no mortality and all patients have had both early and late follow-up echocardiography. Five patients have zero to trace aortic insufficiency, four patients have trace to mild aortic insufficiency, and one patient has mild or "1+" aortic insufficiency. Aortic insufficiency has not progressed in any patient during the 18 months of follow-up. The patient with 1+ aortic insufficiency has no activity limits, good ventricular function, and no evidence of congestive symptoms. One patient who had extensive thoracoabdominal aneurysmal disease has undergone subsequent replacement of the descending aorta to the level of the renal arteries and has done well. Aortic valve-sparing replacement of the aortic root is an excellent procedure for any patient with an ascending aortic aneurysm and an anatomically salvageable valve. We believe that by modifying the proximal conduit and creating a "pseudosinus" into which the leaflets can retract without contact of the cylindrical conduit we may increase the longevity of the native aortic valve in this procedure.

[1]  M. Davies,et al.  Pathology of cardiac valves , 1980 .

[2]  L. Talbot,et al.  The fluid mechanics of the aortic valve , 1969, Journal of Fluid Mechanics.

[3]  M. Thubrikar,et al.  Stress sharing between the sinus and leaflets of canine aortic valve. , 1986, The Annals of thoracic surgery.

[4]  N. Kouchoukos,et al.  Eleven-year experience with composite graft replacement of the ascending aorta and aortic valve. , 1986, The Journal of thoracic and cardiovascular surgery.

[5]  Ross Dn Biological tissue in heart valve replacement. , 1973, [Zasshi] [Journal]. Nihon Kyobu Geka Gakkai.

[6]  D. Te When, why, and how should the native aortic valve be preserved in patients with annuloaortic ectasia or Marfan syndrome? , 1993 .

[7]  J. Matloff,et al.  Ten-year experience with the St. Jude Medical valve for primary valve replacement. , 1990, The Journal of thoracic and cardiovascular surgery.

[8]  D. Cooley,et al.  Durability and low thrombogenicity of the St. Jude Medical valve at 5-year follow-up. , 1986, The Annals of thoracic surgery.

[9]  R. Emery,et al.  Ten years' experience with the St. Jude Medical valve prosthesis. , 1989, The Annals of thoracic surgery.

[10]  G. Laub,et al.  Early and late-phase events after valve replacement with the St. Jude Medical prosthesis in 1200 patients. , 1994, The Journal of thoracic and cardiovascular surgery.

[11]  R. T. Bailey,et al.  Ten-year results with the St. Jude Medical prosthesis. , 1990, The American journal of cardiology.

[12]  H. Bentall,et al.  A technique for complete replacement of the ascending aorta , 1968, Thorax.

[13]  W. Edwards,et al.  Surgical pathology of pure aortic insufficiency: a study of 225 cases. , 1984, Mayo Clinic proceedings.

[14]  Brian John Bellhouse,et al.  Velocity and pressure distributions in the aortic valve , 1969, Journal of Fluid Mechanics.

[15]  M. Debakey,et al.  The St. Jude valve prosthesis: analysis of the clinical results in 815 implants and the need for systemic anticoagulation. , 1989, Journal of the American College of Cardiology.

[16]  T. David,et al.  An aortic valve-sparing operation for patients with aortic incompetence and aneurysm of the ascending aorta. , 1992, The Journal of thoracic and cardiovascular surgery.

[17]  V. McKusick,et al.  Surgical Treatment of Aneurysms of the Ascending Aorta in the Marfan Syndrome , 1986 .

[18]  William H. Beyer,et al.  CRC standard mathematical tables , 1976 .

[19]  L. Edmunds,et al.  Simultaneous implantation of St. Jude Medical aortic and mitral prostheses. , 1987, The Journal of thoracic and cardiovascular surgery.

[20]  F. Robicsek,et al.  Leonardo da Vinci and the sinuses of Valsalva. , 1991, The Annals of thoracic surgery.