Fast Spin Echo Imaging-Based Electric Property Tomography With K-Space Weighting via ${T}_{2}$ Relaxation (rEPT)

Magnetic resonance electrical property tomography (MREPT) is a technique used to extract the electrical properties of tissues (conductivity in particular) using a magnetic resonance imaging system. In this paper, we propose an improved data acquisition scheme for the electrical property tomography technique by utilizing <inline-formula> <tex-math notation="LaTeX">${T} _{2}$ </tex-math></inline-formula> modulation in fast spin echo (FSE) imaging. This technique was motivated by a numerical analysis of conductivity reconstruction in the frequency domain; results reveal the spatial frequency-dependent noise texture of conventional methods. A data-acquisition scheme using the FSE sequence was formulated to concentrate the signal within a specific frequency range where notable noise amplification is observed in the conventional method. Through numerical studies, the performance of the proposed acquisition was investigated. Furthermore, a compensation scheme was applied to reduce quantification errors due to tissue-specific <inline-formula> <tex-math notation="LaTeX">${T} _{2}$ </tex-math></inline-formula> modulation, which is inherent in FSE imaging. The technique was applied to phantom and <italic>in vivo</italic> experiments. Results showed improved conductivity contrasts in both experiments, as compared with conventional MREPT methods.

[1]  Bin He,et al.  Gradient‐based electrical properties tomography (gEPT): A robust method for mapping electrical properties of biological tissues in vivo using magnetic resonance imaging , 2015, Magnetic resonance in medicine.

[2]  W. Joines,et al.  The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz. , 1994, Medical physics.

[3]  Daniel Hernandez,et al.  Denoising of B₁⁺ field maps for noise-robust image reconstruction in electrical properties tomography. , 2014, Medical physics.

[4]  L. Sha,et al.  A review of dielectric properties of normal and malignant breast tissue , 2002, Proceedings IEEE SoutheastCon 2002 (Cat. No.02CH37283).

[5]  Klaas P Pruessmann,et al.  Encoding and reconstruction in parallel MRI , 2006, NMR in biomedicine.

[6]  M F McNitt-Gray,et al.  Application of the noise power spectrum in modern diagnostic MDCT: part I. Measurement of noise power spectra and noise equivalent quanta , 2007, Physics in medicine and biology.

[7]  D. Ortendahl,et al.  Measuring signal-to-noise ratios in MR imaging. , 1989, Radiology.

[8]  Ryan J. Halter,et al.  An Inverse Problems Approach to MR-EPT Image Reconstruction , 2016, IEEE Transactions on Medical Imaging.

[9]  Min-Oh Kim,et al.  Simultaneous quantitative mapping of conductivity and susceptibility using a double‐echo ultrashort echo time sequence: Example using a hematoma evolution study , 2016, Magnetic resonance in medicine.

[10]  Tobias Voigt,et al.  Quantitative conductivity and permittivity imaging of the human brain using electric properties tomography , 2011, Magnetic resonance in medicine.

[11]  J. Hennig Multiecho imaging sequences with low refocusing flip angles , 1988 .

[12]  Maria Lyra,et al.  Filtering in SPECT Image Reconstruction , 2011, Int. J. Biomed. Imaging.

[13]  Necip Gurler,et al.  Convection-Reaction Equation Based Magnetic Resonance Electrical Properties Tomography (cr-MREPT) , 2014, IEEE Transactions on Medical Imaging.

[14]  C. S. Poon,et al.  Practical T2 quantitation for clinical applications , 1992, Journal of magnetic resonance imaging : JMRI.

[15]  G T Gullberg,et al.  Gibbs artifact removal in magnetic resonance imaging. , 1987, Medical physics.

[16]  Dianne P. O'Leary,et al.  Restoring Images Degraded by Spatially Variant Blur , 1998, SIAM J. Sci. Comput..

[17]  E. Samei,et al.  Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems. , 1999, Medical physics.

[18]  Qin Qin,et al.  Point spread functions of the T2 decay in k-space trajectories with long echo train. , 2012, Magnetic resonance imaging.

[19]  Hiroyuki Abe,et al.  Estimation of Breast Tumor Conductivity using Parabolic Phase Fitting , 2012 .

[20]  Stuchly,et al.  Dielectric properties of breast carcinoma and the surrounding tissues , 1988, IEEE Transactions on Biomedical Engineering.

[21]  Dong-Hyun Kim,et al.  MR‐based conductivity imaging using multiple receiver coils , 2016, Magnetic resonance in medicine.

[22]  R. Busse,et al.  Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast , 2006, Magnetic resonance in medicine.

[23]  Min-Oh Kim,et al.  Initial study on in vivo conductivity mapping of breast cancer using MRI , 2015, Journal of magnetic resonance imaging : JMRI.

[24]  K. Scheffler,et al.  Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS) , 2003, Magnetic resonance in medicine.

[25]  Jin Keun Seo,et al.  Recent Progress and Future Challenges in MR Electric Properties Tomography , 2013, Comput. Math. Methods Medicine.

[26]  K R Foster,et al.  Myocardial Electrical Impedance Mapping of Ischemic Sheep Hearts and Healing Aneurysms , 1993, Circulation.

[27]  E M Haacke,et al.  Extraction of conductivity and permittivity using magnetic resonance imaging , 1991 .

[28]  Aart J. Nederveen,et al.  CSI-EPT: A Contrast Source Inversion Approach for Improved MRI-Based Electric Properties Tomography , 2015, IEEE Transactions on Medical Imaging.

[29]  Jin Keun Seo,et al.  Magnetic resonance-based reconstruction method of conductivity and permittivity distributions at the Larmor frequency , 2014, 1409.6095.

[30]  O. Doessel,et al.  Patient‐individual local SAR determination: In vivo measurements and numerical validation , 2012, Magnetic resonance in medicine.

[31]  Peter R Luijten,et al.  B  1+ Phase mapping at 7 T and its application for in vivo electrical conductivity mapping , 2012, Magnetic resonance in medicine.

[32]  Ohin Kwon,et al.  Error Analysis of Nonconstant Admittivity for MR-Based Electric Property Imaging , 2012, IEEE Transactions on Medical Imaging.

[33]  Daniel K Sodickson,et al.  Single acquisition electrical property mapping based on relative coil sensitivities: A proof‐of‐concept demonstration , 2015, Magnetic resonance in medicine.

[34]  Necip Gurler,et al.  Gradient‐based electrical conductivity imaging using MR phase , 2017, Magnetic resonance in medicine.

[35]  Jan J W Lagendijk,et al.  Ultra fast electromagnetic field computations for RF multi-transmit techniques in high field MRI , 2009, Physics in medicine and biology.

[36]  Jung Hyun Yoon,et al.  Correlation between conductivity and prognostic factors in invasive breast cancer using magnetic resonance electric properties tomography (MREPT) , 2016, European Radiology.

[37]  L. Stalpers,et al.  Feasibility of Electric Property Tomography of pelvic tumors at 3T , 2015, Magnetic resonance in medicine.

[38]  Seung-Kyun Lee,et al.  On conductivity, permittivity, apparent diffusion coefficient, and their usefulness as cancer markers at MRI frequencies , 2015, Magnetic resonance in medicine.

[39]  L. Stalpers,et al.  In vivo electric conductivity of cervical cancer patients based on B1+ ?> maps at 3T MRI , 2016, Physics in medicine and biology.

[40]  J Star-Lack,et al.  Reduced spatial side lobes in chemical‐shift imaging , 1999, Magnetic resonance in medicine.

[41]  Olaf Dössel,et al.  Determination of Electric Conductivity and Local SAR Via B1 Mapping , 2009, IEEE Transactions on Medical Imaging.

[42]  D. Noll,et al.  A regularized, model‐based approach to phase‐based conductivity mapping using MRI , 2017, Magnetic resonance in medicine.

[43]  Seung-Kyun Lee,et al.  Theoretical Investigation of Random Noise-Limited Signal-to-Noise Ratio in MR-Based Electrical Properties Tomography , 2015, IEEE Transactions on Medical Imaging.

[44]  Elfar Adalsteinsson,et al.  Simple analytic variable density spiral design , 2003, Magnetic resonance in medicine.

[45]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[46]  P M Joseph,et al.  A matched filter echo summation technique for MRI. , 1995, Magnetic resonance imaging.

[47]  D. Alsop,et al.  The sensitivity of low flip angle RARE imaging , 1997, Magnetic resonance in medicine.

[48]  Wei Sun,et al.  Tissue Electrical Property Mapping From Zero Echo-Time Magnetic Resonance Imaging , 2015, IEEE Transactions on Medical Imaging.

[49]  Andreas Schuster,et al.  CONDUCTIVITY IMAGING OF AN ISCHEMIC PIG HEART MODEL USING ELECTRIC PROPERTIES TOMOGRAPHY , 2011 .

[50]  C. Beaulieu,et al.  Reduction of ringing and blurring artifacts in fast spin‐echo imaging , 1993, Journal of magnetic resonance imaging : JMRI.