Towards an Integrated Framework for Predicting Visual Comfort Conditions from Luminance-based Metrics in Perimeter Daylit Spaces

The authors test 168 luminance-calibrated high dynamic range photographs with associated subjective user data against a set of plausible visual comfort metrics and identify metric thresholds at which discomfort can be consistently identified with minimal false-positives. Correlations were identified with vertical eye illuminance, DGI, DGP 5 ∗ Ltask, max. window luminance and max. workplane luminance. These five metrics in combination, tested against a separate evaluation dataset consisting of 584 measurements, identify 65.2% of discomfort during periods where direct sunlight may enter the test room. The discussion identifies necessary aspects of future work in varied space types and consideration of the view of occupants.

[1]  Gillian Isoardi,et al.  Post occupancy evaluations relating to discomfort glare : a study of green buildings in Brisbane , 2013 .

[2]  Marilyne Andersen,et al.  Uncovering relationships between view direction patterns and glare perception in a daylit workspace , 2013 .

[3]  Jan Wienold,et al.  Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD cameras , 2006 .

[4]  Kyle Konis,et al.  Predicting visual comfort in side-lit open-plan core zones: Results of a field study pairing high dynamic range images with subjective responses , 2014 .

[5]  Denis Fan,et al.  Evidence-based daylight research: Development of a new visual comfort monitoring method , 2009 .

[6]  Alison G. Kwok,et al.  Mechanical and electrical equipment for buildings , 2015 .

[7]  Mehlika Inanici,et al.  Evaluation of high dynamic range photography as a luminance data acquisition system , 2006 .

[8]  Christoph F. Reinhart,et al.  The ‘adaptive zone’ – A concept for assessing discomfort glare throughout daylit spaces , 2012 .

[9]  Gregory J. Ward,et al.  The RADIANCE lighting simulation and rendering system , 1994, SIGGRAPH.

[10]  R. G. Hopkinson,et al.  Glare from daylighting in buildings. , 1972, Applied ergonomics.

[11]  Mehlika Inanici,et al.  A Critical Investigation of Common Lighting Design Metrics for Predicting Human Visual Comfort in Offices with Daylight , 2014 .

[12]  Hicham Johra,et al.  Verification of simple illuminance based measures for indication of discomfort glare from windows , 2015 .

[13]  Gillian Isoardi,et al.  Discomfort glare in open plan green buildings , 2014 .

[14]  Christoph F. Reinhart,et al.  PREDICTING VISUAL COMFORT CONDITIONS IN A LARGE DAYLIT SPACE BASED ON LONG-TERM OCCUPANT EVALUATIONS: A FIELD STUDY , 2013 .

[15]  Christoph F. Reinhart,et al.  Assessing Disability Glare Potential of Reflections from New Construction , 2014 .

[16]  Niloofar Moghbel New Model for VDT Associated Visual Comfort in Office Spaces , 2012 .

[17]  Denis Fan,et al.  A Data Collection Method for Long-Term Field Studies of Visual Comfort in Real-World Daylit Office Environments , 2009 .

[18]  Mehlika Inanici,et al.  The Effect of Luminance Distribution Patterns on Occupant Preference in a Daylit Office Environment , 2010 .

[19]  Van Den Wymelenberg,et al.  Evaluating Human Visual Preference and Performance in an Office Environment Using Luminance-based Metrics , 2012 .