A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility.

UNLABELLED We have developed a new, completely automatic 3-dimensional software approach to quantitative perfusion SPECT. The main features of the software are myocardial sampling based on an ellipsoid model; use of the entire count profile between the endocardial and epicardial surfaces; independence of the algorithm from myocardial shape, size, and orientation and establishment of a standard 3-dimensional point-to-point correspondence among all sampled myocardial regions; automatic generation of quantitative measurements and 5-point semiquantitative scores for each of 20 myocardial segments and automatic derivation of summed perfusion scores; and automatic generation of normal limits for any given patient population on the basis of data fractionally normalized to minimize hot spot artifacts. METHODS The new algorithm was tested on the tomographic images of 420 patients studied with a rest 201TI (111-167 MBq, 35 s/projection)-stress 99mTc-sestamibi (925-1480 MBq, 25 s/projection) separate dual-isotope protocol on a single-detector camera, a dual-detector 90 degrees camera, and a triple-detector camera. RESULTS The algorithm was successful in 397 of 420 patients (94.5%) and 816 of 840 image datasets (97.1%), with a statistically significant difference between the success rates of the 201TI images (399/ 420, or 95.0%) and the 99mTc images (417/420, or 99.3%; P < 0.001). Algorithm failure was caused by extracardiac uptake (10/24, or 41.7%) or inaccurate identification of the valve plane because of low count statistics (14/24, or 58.3%) and was obviated by simply limiting the image volume in which the software operates. Reproducibility of measurements of summed perfusion scores (r = 0.999 and 1 for stress and rest, respectively), global defect extent (r = 0.999 and 1 for stress and rest, respectively), and segmental perfusion scores (exact agreement = 99.9%, kappa = 0.998 for stress and 0.997 for rest) was extremely high. CONCLUSION Automatic 3-dimensional quantitation of perfusion from 201Tl and 99mTc-sestamibi images is feasible and reproducible. The described software, because it is based on the same sampling scheme used for gated SPECT analysis, ensures intrinsically perfect registration of quantitative perfusion with quantitative regional wall motion and thickening information, if gated SPECT is used.

[1]  D. Berman,et al.  Quantitative single photon emission computed thallium-201 tomography for detection and localization of coronary artery disease: optimization and prospective validation of a new technique. , 1989, Journal of the American College of Cardiology.

[2]  G. Beller,et al.  Spatial and temporal quantitation of plane thallium myocardial images. , 1981, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  E. Depuey,et al.  Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease. , 1988, Circulation.

[4]  Y. Yonekura,et al.  Stress thallium-201 transaxial emission computed tomography: quantitative versus qualitative analysis for evaluation of coronary artery disease. , 1984, Journal of the American College of Cardiology.

[5]  G Germano,et al.  Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. , 1995, Journal of the American College of Cardiology.

[6]  D. Berman,et al.  Quantitative same-day rest-stress technetium-99m-sestamibi SPECT: definition and validation of stress normal limits and criteria for abnormality. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  D. Berman,et al.  Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study. , 1993, Journal of the American College of Cardiology.

[8]  D. Berman,et al.  Alternative referent standards for cardiac normality. Implications for diagnostic testing. , 1984, Annals of internal medicine.

[9]  D. Berman,et al.  Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. , 1997, Journal of the American College of Cardiology.

[10]  T L Faber,et al.  A model-based four-dimensional left ventricular surface detector. , 1991, IEEE transactions on medical imaging.

[11]  D. Chesler,et al.  A new approach to quantitation of exercise thallium-201 scintigraphy before and after an intervention: application to define the impact of coronary angioplasty on regional myocardial perfusion. , 1984, American heart journal.

[12]  J R Stratton,et al.  Quantitation of size of relative myocardial perfusion defect by single-photon emission computed tomography. , 1984, Circulation.

[13]  D S Berman,et al.  Quantification of rotational thallium-201 myocardial tomography. , 1985, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  D S Berman,et al.  Quantitative analysis of stress thallium-201 myocardial scintigrams: a multicenter trial. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  E G DePuey,et al.  Reversibility bull's-eye: a new polar bull's-eye map to quantify reversibility of stress-induced SPECT thallium-201 myocardial perfusion defects. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  M L Goris,et al.  Modelling the integration of myocardial regional perfusion and function , 1994, Nuclear medicine communications.

[17]  J. Mattera,et al.  Quantitative planar thallium-201 stress scintigraphy: a critical evaluation of the method. , 1985, Seminars in nuclear medicine.

[18]  D. Berman,et al.  Multicenter trial validation for quantitative analysis of same-day rest-stress technetium-99m-sestamibi myocardial tomograms. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  G Germano,et al.  Automatic reorientation of three-dimensional, transaxial myocardial perfusion SPECT images. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.