EVALUATION OF ARBITRARY INTEGER BASED MULTIPLE TUNED MASS DAMPERS FOR STRUCTURES

In contrast with the odd number based multiple tuned mass dampers (ON-MTMD) used conventionally, which is targeted at the central natural frequency, the arbitrary integer based multiple tuned mass dampers (AI-MTMD) is proposed for the convenient applications of MTMD by giving up the central natural frequency hypothesis. The total number of the TMD units constituting the AI-MTMD may be selected as an arbitrary integer according to the practical requirements. In terms of the dynamic magnification factors (DMF) of the AI-MTMD structure system, the criterion for evaluating the optimum parameters and effectiveness of the AI-MTMD is selected as the minimization of the minimum values of the maximum DMF of the structure with the AI-MTMD. Employing the maximum DMF of every mass block in the AI-MTMD, the stroke of the AI-MTMD is simultaneously evaluated. The results indicate that both the AI-MTMD and the ON-MTMD can practically render the same performance, thus demonstrating that the former can be more convenient in mitigating structural oscillations with respect to the ON-MTMD stuck to the central natural frequency hypothesis.

[1]  Masato Abe,et al.  Tuned mass dampers for structures with closely spaced natural frequencies , 1995 .

[2]  R. S. Jangid DYNAMIC CHARACTERISTICS OF STRUCTURES WITH MULTIPLE TUNED MASS DAMPERS , 1995 .

[3]  Ming Gu,et al.  Parametric study on multiple tuned mass dampers for buffeting control of Yangpu Bridge , 2001 .

[4]  Genda Chen,et al.  OPTIMAL PLACEMENT OF MULTIPLE TUNED MASS DAMPERS FOR SEISMIC STRUCTURES , 2001 .

[5]  K. Xu,et al.  Dynamic characteristics of multiple substructures with closely spaced frequencies , 1992 .

[6]  Chunxiang Li,et al.  Optimum multiple tuned mass dampers for structures under the ground acceleration based on DDMF and ADMF , 2002 .

[7]  Ahsan Kareem,et al.  Performance of Multiple Mass Dampers Under Random Loading , 1995 .

[8]  H. Yamaguchi,et al.  Fundamental characteristics of Multiple Tuned Mass Dampers for suppressing harmonically forced oscillations , 1993 .

[9]  Chunxiang Li,et al.  Active Multiple Tuned Mass Dampers: A New Control Strategy , 2003 .

[10]  Chunxiang Li,et al.  Evaluation of multiple active lever-type tuned mass dampers for structures under ground acceleration , 2004 .

[11]  Chunxiang Li Performance of multiple tuned mass dampers for attenuating undesirable oscillations of structures under the ground acceleration , 2000 .

[12]  Y. Fujino,et al.  Dynamic characterization of multiple tuned mass dampers and some design formulas , 1994 .

[13]  Dorothy Reed,et al.  Analysis of uniformly and linearly distributed mass dampers under harmonic and earthquake excitation , 2001 .

[14]  Chunxiang Li,et al.  Optimum multiple tuned mass dampers for structures under the ground acceleration based on the uniform distribution of system parameters , 2003 .

[15]  Chunxiang Li,et al.  FURTHER CHARACTERISTICS FOR MULTIPLE TUNED MASS DAMPERS , 2002 .

[16]  R. S. Jangid Optimum Multiple Tuned Mass Dampers for base‐excited undamped system , 1999 .