ANN and ANFIS models for performance evaluation of a vertical ground source heat pump system

The aim of this study is to demonstrate the comparison of an artificial neural network (ANN) and an adaptive neuro-fuzzy inference system (ANFIS) for the prediction performance of a vertical ground source heat pump (VGSHP) system. The VGSHP system using R-22 as refrigerant has a three single U-tube ground heat exchanger (GHE) made of polyethylene pipe with a 40mm outside diameter. The GHEs were placed in a vertical boreholes (VBs) with 30 (VB1), 60 (VB2) and 90 (VB3)m depths and 150mm diameters. The monthly mean values of COP for VB1, VB2 and VB3 are obtained to be 3.37/1.93, 3.85/2.37, and 4.33/3.03, respectively, in cooling/heating seasons. Experimental performances were performed to verify the results from the ANN and ANFIS approaches. ANN model, Multi-layered Perceptron/Back-propagation with three different learning algorithms (the Levenberg-Marquardt (LM), Scaled Conjugate Gradient (SCG) and Pola-Ribiere Conjugate Gradient (CGP) algorithms and the ANFIS model were developed using the same input variables. Finally, the statistical values are given in as tables. This paper shows the appropriateness of ANFIS for the quantitative modeling of GSHP systems.

[1]  Vojislav Kecman,et al.  Neural networks—a new approach to model vapour‐compression heat pumps , 2001 .

[2]  Arif Hepbasli,et al.  Performance evaluation of a vertical ground‐source heat pump system in Izmir, Turkey , 2002 .

[3]  Soteris A. Kalogirou,et al.  Applications of artificial neural-networks for energy systems , 2000 .

[4]  Robert Babuska,et al.  Fuzzy Modeling for Control , 1998 .

[5]  Simon Haykin,et al.  Neural Networks: A Comprehensive Foundation , 1998 .

[6]  Abdulkadir Sengür,et al.  Wavelet transform and adaptive neuro-fuzzy inference system for color texture classification , 2008, Expert Syst. Appl..

[7]  Yusuf Ali Kara,et al.  Experimental performance evaluation of a closed‐loop vertical ground source heat pump in the heating mode using energy analysis method , 2007 .

[8]  Hongxing Yang,et al.  Numerical analysis and experimental validation of heat transfer in ground heat exchangers in alternative operation modes , 2008 .

[9]  Yasuhiro Hamada,et al.  Field performance of an energy pile system for space heating , 2007 .

[10]  T. N. Singh,et al.  Prediction of thermal conductivity of rock through physico-mechanical properties , 2007 .

[11]  C. K. Lee,et al.  Computer simulation of borehole ground heat exchangers for geothermal heat pump systems , 2008 .

[12]  Mustafa Inalli,et al.  Seasonal cooling performance of a ground-coupled heat pump system in a hot and arid climate , 2005 .

[13]  Mehmet Esen,et al.  Energy and exergy analysis of a ground-coupled heat pump system with two horizontal ground heat exchangers , 2007 .

[14]  D. Oneal,et al.  Thermal interference of adjacent legs in a vertical U-tube heat exchanger for a ground-coupled heat pump , 1996 .

[15]  Elif Derya Übeyli,et al.  Adaptive neuro-fuzzy inference system for classification of EEG signals using wavelet coefficients , 2005, Journal of Neuroscience Methods.

[16]  S. Kalogirou,et al.  A new approach using artificial neural networks for determination of the thermodynamic properties of fluid couples , 2005 .

[17]  Abdulkadir Sengur,et al.  An expert system based on linear discriminant analysis and adaptive neuro-fuzzy inference system to diagnosis heart valve diseases , 2008 .

[18]  Patrick van der Smagt,et al.  Introduction to neural networks , 1995, The Lancet.

[19]  Chunlei Zhang Generalized correlation of refrigerant mass flow rate through adiabatic capillary tubes using artificial neural network , 2005 .

[20]  Martin Fodslette Meiller A Scaled Conjugate Gradient Algorithm for Fast Supervised Learning , 1993 .

[21]  Saffa Riffat,et al.  A novel rainwater–ground source heat pump – Measurement and simulation , 2007 .

[22]  Steven P. Rottmayer Simulation of Ground Coupled Vertical U-Tube Heat Exchangers , 1997 .

[23]  Mustafa Inalli,et al.  Technoeconomic appraisal of a ground source heat pump system for a heating season in eastern Turkey , 2006 .

[24]  Murat Hosoz,et al.  Artificial neural network analysis of a refrigeration system with an evaporative condenser , 2006 .

[25]  Zhihao Chen,et al.  Thermal performances of different types of underground heat exchangers , 2006 .

[26]  V. C. Mei,et al.  Theoretical heat pump ground coil analysis with variable ground farfield boundary conditions , 1986 .

[27]  Mustafa Inalli,et al.  Numerical and experimental analysis of a horizontal ground-coupled heat pump system , 2007 .

[28]  Engin Avci,et al.  Analysis of adaptive-network-based fuzzy inference system (ANFIS) to estimate buoyancy-induced flow field in partially heated triangular enclosures , 2008, Expert Syst. Appl..

[29]  Daniel Pahud,et al.  Comparison of the thermal performance of double U-pipe borehole heat exchangers measured in situ , 2001 .

[30]  Myoung-Souk Yeo,et al.  Application of artificial neural network to predict the optimal start time for heating system in building , 2003 .

[31]  Vojislav Kecman,et al.  New approach to dynamic modelling of vapour-compression liquid chillers: artificial neural networks , 2001 .

[32]  İlhan Ceylan,et al.  Modeling of a hazelnut dryer assisted heat pump by using artificial neural networks , 2008 .

[33]  Lingen Chen,et al.  Ground heat exchanger temperature distribution analysis and experimental verification , 2002 .

[34]  E. Arcaklioğlu,et al.  Artificial neural network analysis of heat pumps using refrigerant mixtures , 2004 .

[35]  Arif Hepbasli,et al.  Experimental study of a closed loop vertical ground source heat pump system , 2003 .

[36]  Mustafa Inalli,et al.  Experimental thermal performance evaluation of a horizontal ground-source heat pump system , 2004 .

[37]  Derk J. Swider,et al.  A comparison of empirically based steady-state models for vapor-compression liquid chillers , 2003 .

[38]  Jyh-Shing Roger Jang,et al.  ANFIS: adaptive-network-based fuzzy inference system , 1993, IEEE Trans. Syst. Man Cybern..