Investigation of stereotactic radiotherapy dose using dosimetry film and Monte Carlo simulations

Abstract This study uses dosimetry film measurements and Monte Carlo simulations to investigate the accuracy of type-a (pencil-beam) dose calculations for predicting the radiation doses delivered during stereotactic radiotherapy treatments of the brain. It is shown that when evaluating doses in a water phantom, the type-a algorithm provides dose predictions which are accurate to within clinically relevant criteria, γ(3%,3 mm), but these predictions are nonetheless subtly different from the results of evaluating doses from the same fields using radiochromic film and Monte Carlo simulations. An analysis of a clinical meningioma treatment suggests that when predicting stereotactic radiotherapy doses to the brain, the inaccuracies of the type-a algorithm can be exacerbated by inadequate evaluation of the effects of nearby bone or air, resulting in dose differences of up to 10% for individual fields. The results of this study indicate the possible advantage of using Monte Carlo calculations, as well as measurements with high-spatial-resolution media, to verify type-a predictions of dose delivered in cranial treatments.

[1]  J. Seco,et al.  Head-and-neck IMRT treatments assessed with a Monte Carlo dose calculation engine , 2005, Physics in medicine and biology.

[2]  E. Yorke,et al.  Use of normal tissue complication probability models in the clinic. , 2010, International journal of radiation oncology, biology, physics.

[3]  Tanya Kairn,et al.  The development of a Monte Carlo system to verify radiotherapy treatment dose calculations , 2009 .

[4]  S Webb,et al.  An investigation of dose calculation accuracy in intensity-modulated radiotherapy of sites in the head & neck. , 2006, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[5]  A. L. Fielding,et al.  Effects of collimator backscatter in an Elekta linac by Monte Carlo simulation , 2009, Australasian Physics & Engineering Sciences in Medicine.

[6]  T Kairn,et al.  Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution. , 2010, Medical physics.

[7]  Luca Cozzi,et al.  Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations , 2006, Physics in medicine and biology.

[8]  T Knöös,et al.  Limitations of a pencil beam approach to photon dose calculations in lung tissue. , 1995, Physics in medicine and biology.

[9]  V. Budach,et al.  Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[11]  T Kairn,et al.  Adapting a generic BEAMnrc model of the BrainLAB m3 micro-multileaf collimator to simulate a local collimation device , 2010, Physics in medicine and biology.

[12]  T Kairn,et al.  Local heterogeneities in early batches of EBT2 film: a suggested solution , 2010, Physics in medicine and biology.

[13]  I. Das,et al.  Small fields: nonequilibrium radiation dosimetry. , 2007, Medical physics.