Management of Instrument Sterilization Workflow in Endodontics: A Systematic Review and Meta-Analysis

Endodontic treatment consists of different working procedures, such as the isolation of the operating field, pulp chamber access, and cleaning and shaping phases with at last the need of a three-dimensional filling of the canals. Each step requires a series of single-use or sterilizable instruments. We have performed a systematic review of different sterilization and disinfection procedures aiming at drawing up a disinfection and sterilization procedure to be used on endodontic instruments. A search on PubMed and Scopus was carried out using the following keywords: “endodontic sterilization,” “endodontic autoclave,” “decontamination dental bur,” “sterilization dental burs,” and “gutta-percha points sterilization.” Eligible articles were included in the qualitative and quantitative analysis. Results of the meta-analysis showed that the most effective method in sterilization is autoclaving. The qualitative analysis showed that the use of single-use or first-use instruments requires presterilization or sterilization procedures, and for reusable tools, attention must be paid to the removal of debris deposited on the blades, not easy to remove manually.

[1]  Robia Ghafoor,et al.  Assessment of contamination on sterilised dental burs after being subjected to various pre-cleaning methods. , 2018, JPMA. The Journal of the Pakistan Medical Association.

[2]  G. Condorelli,et al.  Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files. , 1999, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[3]  P. Tramini,et al.  Observance of Sterilization Protocol Guideline Procedures of Critical Instruments for Preventing Iatrogenic Transmission of Creutzfeldt-Jakob Disease in Dental Practice in France, 2017 , 2018, International journal of environmental research and public health.

[4]  T. Raju,et al.  Sterilizing Endodontic Files by four different sterilization methods to prevent cross-infection - An In-vitro Study. , 2013, Journal of international oral health : JIOH.

[5]  R. Baxter,et al.  Plasma cleaning of dental instruments. , 2004, The Journal of hospital infection.

[6]  Mark Loeb,et al.  Newcastle-Ottawa Scale: comparing reviewers’ to authors’ assessments , 2014, BMC Medical Research Methodology.

[7]  T. Fang,et al.  Study of deformation and shape recovery of NiTi nanowires under torsion , 2013, Journal of Molecular Modeling.

[8]  Pratima R Shenoi,et al.  Evaluation of new technique of sterilization using biological indicator , 2017, Journal of conservative dentistry : JCD.

[9]  J. P. Pruett,et al.  Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments. , 1998, Journal of endodontics.

[10]  D. Ciavarella,et al.  Increase the glyde path diameter improves the centering ability of F6 Skytaper , 2018, European Journal of Dentistry.

[11]  J. Ioannidis,et al.  The PRISMA Statement for Reporting Systematic Reviews and Meta-Analyses of Studies That Evaluate Health Care Interventions: Explanation and Elaboration , 2009, Annals of Internal Medicine [serial online].

[12]  Bilal Mourshed,et al.  The Effect of surface topographical changes of two different surface treatments rotary instrument , 2018, Journal of clinical and experimental dentistry.

[13]  M. S. Namazikhah,et al.  Gutta-percha: a look at the need for sterilization. , 2000, Journal of the California Dental Association.

[14]  D. Veldkamp,et al.  Glutaraldehyde in endodontic therapy: philosophy and practice. , 1983, E -journal of dentistry.

[15]  Toshiyuki Takase,et al.  The effect of thermal treatment on the resistance of nickel-titanium rotary files in cyclic fatigue. , 2007, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[16]  M. Assaf,et al.  Cleaning endodontic files in a washer disinfector , 2008, BDJ.

[17]  A. Morrison,et al.  Dental burs and endodontic files: are routine sterilization procedures effective? , 2010, Texas dental journal.

[18]  E. Pavlidou,et al.  Effect of heat sterilization on surface characteristics and microstructure of Mani NRT rotary nickel-titanium instruments. , 2006, International endodontic journal.

[19]  G. Powell,et al.  Comparison of three lasers for dental instrument sterilization , 1991, Lasers in surgery and medicine.

[20]  S. Hugar,et al.  Decontamination methods used for dental burs - a comparative study. , 2014, Journal of clinical and diagnostic research : JCDR.

[21]  Mark D. Roberts,et al.  Comparison of autoclaving effects on torsional deformation and fracture resistance of three innovative endodontic file systems. , 2011, Journal of endodontics.

[22]  K. Abinaya,et al.  Efficacy of peracetic acid in rapid disinfection of Resilon and gutta-percha cones compared with sodium hypochlorite, chlorhexidine, and povidone-iodine. , 2013, Journal of endodontics.

[23]  C. Koga‐Ito,et al.  Effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones. , 2011, Brazilian oral research.

[24]  M. Prasad,et al.  An in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography. , 2013, Journal of international oral health : JIOH.

[25]  D. Orstavik,et al.  Influence of antiseptic storage solutions on physical properties of endodontic guttapercha points. , 1985, Scandinavian journal of dental research.

[26]  A C Mellor,et al.  The effect of pre-soaking and time in the ultrasonic cleaner on the cleanliness of sterilized endodontic files. , 2006, International endodontic journal.

[27]  J. Nicoli,et al.  Efficacy of chemical sterilization and storage conditions of gutta-percha cones. , 2001, International endodontic journal.

[28]  V. Fontanella,et al.  SEM evaluation of thermoplastic endodontic materials alterations after disinfection: A new experimental model , 2011, Microscopy research and technique.

[29]  E. Berutti,et al.  Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments. , 2006, International endodontic journal.

[30]  C. Palenik,et al.  The use of paraformaldehyde powder for the sterile storage of gutta-percha cones. , 1986, Journal of endodontics.

[31]  Gianluca Gambarini,et al.  Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments. , 2012, Journal of endodontics.

[32]  R. Venkatasubramanian,et al.  Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: an in vitro study. , 2010, Journal of the Indian Society of Pedodontics and Preventive Dentistry.

[33]  S. Deepthi,et al.  Pathological evaluation for sterilization of routinely used prosthodontic and endodontic instruments , 2015, Journal of International Society of Preventive & Community Dentistry.

[34]  F. Silvestre,et al.  Evaluation of chemical-physical properties and cytocompatibility of TheraCal LC. , 2017, Journal of biological regulators and homeostatic agents.

[35]  F. Montagner,et al.  Residual effects and surface alterations in disinfected gutta-percha and Resilon cones. , 2007, Journal of endodontics.

[36]  M. Eghbal,et al.  An energy-dispersive X-ray analysis and SEM study of debris remaining on endodontic instruments after ultrasonic cleaning and autoclave sterilization. , 2005, Australian endodontic journal : the journal of the Australian Society of Endodontology Inc.

[37]  H. Messer,et al.  Cleaning of rotary nickel-titanium endodontic instruments. , 2004, International endodontic journal.

[38]  A. Chohayeb,et al.  Effective surface sterilization of gutta-percha points. , 1983, Oral surgery, oral medicine, and oral pathology.

[39]  K. Kum,et al.  Effects of short-term chemical disinfection of gutta-percha cones: identification of affected microbes and alterations in surface texture and physical properties. , 2007, Journal of endodontics.

[40]  H. Messer,et al.  A cleaning protocol for rotary nickel-titanium endodontic instruments. , 2004, Australian dental journal.

[41]  D. Ciavarella,et al.  Influence of Operator's Experience on the Shaping Ability of Protaper Universal and Waveone Systems: A Comparative Study on Simulated Root Canals , 2016, The open dentistry journal.

[42]  F. Setzer,et al.  Influence of combined cyclic fatigue and torsional stress on the fracture point of nickel-titanium rotary instruments. , 2013, Journal of endodontics.

[43]  N. Richards,et al.  Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations. , 2000, Journal of endodontics.

[44]  M. Brito-Júnior,et al.  Antibacterial activity of a plant extract and its potential for disinfecting gutta-percha cones. , 2012, Acta odontológica latinoamericana.

[45]  S. Montgomery Chemical decontamination of gutta-percha cones with polyvinylpyrrolidone-iodine. , 1971, Oral surgery, oral medicine, and oral pathology.

[46]  A. Santarelli,et al.  Novel Hydroxyapatite Biomaterial Covalently Linked to Raloxifene , 2014, International journal of immunopathology and pharmacology.

[47]  J. Higgins,et al.  Cochrane Handbook for Systematic Reviews of Interventions , 2010, International Coaching Psychology Review.

[48]  P. Tomson,et al.  Contemporary obturation of the root canal system , 2014, BDJ.

[49]  Guido La Rosa,et al.  Torsional and Cyclic Fatigue Resistance of a New Nickel-Titanium Instrument Manufactured by Electrical Discharge Machining. , 2016, Journal of endodontics.

[50]  L. Lo Muzio,et al.  In vitro evaluation of the cytotoxic activity of three epoxy resin-based endodontic sealers. , 2018, Dental materials journal.

[51]  Teresa Roberta Tripib,et al.  Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files , 1999 .

[52]  Luigi Laino,et al.  ProTaper and WaveOne systems three-dimensional comparison of device parameters after the shaping technique. A micro-CT study on simulated root canals. , 2015, International journal of clinical and experimental medicine.

[53]  P. Marsh,et al.  Cleanability of dental instruments – implications of residual protein and risks from Creutzfeldt-Jakob disease , 2007, BDJ.

[54]  T. Pollard Cross-infection control , 1993, British Dental Journal.

[55]  J. Bagg,et al.  Contaminated dental instruments. , 2002, The Journal of hospital infection.

[56]  C. L. Cardoso,et al.  Rapid sterilization of gutta-percha cones with glutaraldehyde. , 1998, Journal of endodontics.

[57]  P. Zilm,et al.  Microbiological evaluation of endodontic files after cleaning and steam sterilization procedures. , 2004, Australian dental journal.

[58]  Wemes Jc,et al.  GLUTARALDEHYDE IN ENDODONTIC THERAPY - PHILOSOPHY AND PRACTICE , 1983 .

[59]  T. Attin,et al.  Antibacterial properties of electron beam-sterilized Gutta-Percha cones. , 2001, Journal of endodontics.

[60]  G. Goodell,et al.  Rapid chairside sterilization of endodontic files using 6% sodium hypochlorite. , 2009, Journal of endodontics.

[61]  A. Qualtrough,et al.  Comparison of an ultrasonic cleaner and a washer disinfector in the cleaning of endodontic files. , 2007, Journal of Hospital Infection.

[62]  A. Williamson,et al.  Comparison of 5.25% sodium hypochlorite, MTAD, and 2% chlorhexidine in the rapid disinfection of polycaprolactone-based root canal filling material. , 2007, Journal of endodontics.

[63]  R. Azevedo,et al.  Structural effects of sodium hypochlorite solutions on gutta-percha cones: atomic force microscopy study. , 2005, Journal of endodontics.

[64]  L. E. Rossman,et al.  The sterilization of endodontic hand files. , 1996, Journal of endodontics.

[65]  L. Lo Muzio,et al.  Sterilisation in Dentistry: A Review of the Literature , 2019, International journal of dentistry.

[66]  N. Chandler,et al.  Lubrication during root canal treatment. , 2018, Australian endodontic journal : the journal of the Australian Society of Endodontology Inc.

[67]  Mahima Tilakchand,et al.  The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: An in vitro atomic force microscopy investigation , 2015, Journal of conservative dentistry : JCD.

[68]  M. Sousa-Neto,et al.  In vitro evaluation of different chemical agents for the decontamination of gutta-percha cones. , 2003, Pesquisa odontologica brasileira = Brazilian oral research.

[69]  N. Ibrahim,et al.  Cross-infection and infection control in dentistry: Knowledge, attitude and practice of patients attended dental clinics in King Abdulaziz University Hospital, Jeddah, Saudi Arabia , 2016, Journal of Infection and Public Health.

[70]  Swati Sharma,et al.  Comparative Evaluation of the Effect of Manufacturing Process on Distortion of Rotary ProFile and Twisted File: An in Vitro SEM Study , 2015, Journal of Dental Research, Dental Clinics, Dental Prospects.

[71]  M. Britto,et al.  Effectiveness of different chemical agents for disinfection of gutta-percha cones. , 2011, Australian endodontic journal : the journal of the Australian Society of Endodontology Inc.

[72]  M. Koçak,et al.  Evaluation of residual antimicrobial effects and surface changes of gutta-percha disinfected with different solutions. , 2011, The journal of contemporary dental practice.

[73]  P. Zilm,et al.  A SEM evaluation of debris removal from endodontic files after cleaning and steam sterilization procedures. , 2004, Australian dental journal.

[74]  L. Gonçalves,et al.  Influence of the geometry of curved artificial canals on the fracture of rotary nickel-titanium instruments subjected to cyclic fatigue tests. , 2013, Journal of endodontics.

[75]  Wade Jt Future is digital. , 2001 .

[76]  G. Sant,et al.  Direct observation of pitting corrosion evolutions on carbon steel surfaces at the nano-to-micro- scales , 2018, Scientific Reports.

[77]  E. F. Iglecias,et al.  Analysis of Demineralized Chemical Substances for Disinfecting Gutta-percha Cones , 2018, Iranian endodontic journal.

[78]  Effect of a combination of torsional and cyclic fatigue preloading on the fracture behavior of K3 and K3XF instruments. , 2015, Journal of endodontics.

[79]  Giuseppe Troiano,et al.  Endodontic irrigants: Different methods to improve efficacy and related problems , 2018, European Journal of Dentistry.

[80]  T. Lwin,et al.  Effects of cleaning, disinfection, and sterilization procedures on the cutting efficiency of endodontic files. , 1996, Journal of endodontics.

[81]  O. Zmener,et al.  Cleaning of endodontic instruments before use. , 1995, Endodontics & dental traumatology.

[82]  C. Canalda-Sahli,et al.  The effect of sterilization on bending and torsional properties of K-files manufactured with different metallic alloys. , 1998, International endodontic journal.

[83]  K. Vickery,et al.  Alcohol fixation of bacteria to surgical instruments increases cleaning difficulty and may contribute to sterilization inefficacy , 2017, American journal of infection control.

[84]  J. Ioannidis,et al.  The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration , 2009, BMJ : British Medical Journal.

[85]  N. Ozalp,et al.  The rapid sterilization of gutta-percha cones with sodium hypochlorite and glutaraldehyde. , 2006, Journal of endodontics.

[86]  P. Dummer,et al.  Deformation of HyFlex CM instruments and their shape recovery following heat sterilization. , 2015, International endodontic journal.

[87]  A. Petrović,et al.  Evaluation of biological debris on endodontic instruments after cleaning and sterilization procedures. , 2010, International endodontic journal.

[88]  S. Dorn,et al.  The crystallization of sodium hypochlorite on gutta-percha cones after the rapid-sterilization technique: an SEM study. , 2003, Journal of endodontics.

[89]  A. D. Keçeci,et al.  Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization , 2013, Journal of applied oral science : revista FOB.

[90]  J. Jones,et al.  Cross-infection control: the role of "in-training" dental nurses. , 1996, Journal of dentistry.

[91]  R. Simão,et al.  The importance of final rinse after disinfection of gutta-percha and Resilon cones. , 2011, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[92]  D. Perrett,et al.  Residual protein levels on reprocessed dental instruments. , 2005, The Journal of hospital infection.

[93]  M. Cicciu',et al.  Cytotoxicity evaluation of five different dual-cured resin cements used for fiber posts cementation. , 2015, International journal of clinical and experimental medicine.

[94]  M. E. Vianna,et al.  Disinfection of gutta-percha cones with chlorhexidine and sodium hypochlorite. , 2005, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[95]  A C D Viana,et al.  Influence of sterilization on mechanical properties and fatigue resistance of nickel-titanium rotary endodontic instruments. , 2006, International endodontic journal.

[96]  T. Özyürek,et al.  The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments , 2017, Restorative dentistry & endodontics.

[97]  R. C. Nelson,et al.  The effect of autoclave sterilization on endodontic files. , 1983, Oral surgery, oral medicine, and oral pathology.

[98]  D. Ciavarella,et al.  Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals , 2016, TheScientificWorldJournal.

[99]  Xin Xu,et al.  Novel Approaches to the Control of Oral Microbial Biofilms , 2018, BioMed research international.