Real-time contrast medium detection in x-ray images by mathematical morphology operators

Abstract. This paper proposes a solution to contrast agent (CA) detection in angiograms by considering x-ray images as intensity images and applying mathematical morphology operators. We present two detection approaches, one based on the intensity infimum and the other based on the dual reconstruction. The evaluation using several data sets shows that both techniques are able to detect the presence of the contrast medium volume. Moreover, the dual reconstruction–based method is proven to be faster in processing time and more effective than the intensity infimum–based method in distinguishing the intensity change at the same location from the displacement of the same region. In addition, we show how to track the CA passage through a region of interest by observing the intensity evolution in successive submasks.

[1]  Pierre Soille,et al.  Morphological Image Analysis: Principles and Applications , 2003 .

[2]  Wilfried Mai,et al.  Comparison between bolus tracking and timing-bolus techniques for renal computed tomographic angiography in normal cats. , 2013, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[3]  Nico Mollet,et al.  Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. , 2004, Radiology.

[4]  K. Bae,et al.  Peak contrast enhancement in CT and MR angiography: when does it occur and why? Pharmacokinetic study in a porcine model. , 2003, Radiology.

[5]  V Raptopoulos,et al.  Comparison of tailored and empiric scan delays for CT angiography of the abdomen. , 1996, AJR. American journal of roentgenology.

[6]  Atoosa Adibi,et al.  Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen , 2014, Iranian journal of radiology : a quarterly journal published by the Iranian Radiological Society.

[7]  Yong Eun Chung,et al.  Variation of the time to aortic enhancement of fixed-duration versus fixed-rate injection protocols. , 2006, AJR. American journal of roentgenology.

[8]  Nicole Vincent,et al.  Active Contours for Bolus Tracking in X-Ray Images Sequences , 2000, MVA.

[9]  A. Carstens,et al.  The comparison of bolus tracking and test bolus techniques for computed tomography thoracic angiography in healthy beagles. , 2013, Journal of the South African Veterinary Association.

[10]  D. Fleischmann,et al.  High-concentration contrast media in MDCT angiography: principles and rationale , 2003, European Radiology.

[11]  Ying Li,et al.  A Voxel-Map Quantitative Analysis Approach for Atherosclerotic Noncalcified Plaques of the Coronary Artery Tree , 2013, Comput. Math. Methods Medicine.

[12]  Zhenyu Wu,et al.  Real-time tracking of contrast bolus propagation in X-ray peripheral angiography , 1998, Proceedings. Workshop on Biomedical Image Analysis (Cat. No.98EX162).

[13]  Thomas Henzler,et al.  Dual-energy CT angiography of the lungs: comparison of test bolus and bolus tracking techniques for the determination of scan delay. , 2012, European journal of radiology.

[14]  Takeo Ishigaki,et al.  Late-arterial and portal-venous phase imaging of the liver with a multislice CT scanner in patients without circulatory disturbances: automatic bolus tracking or empirical scan delay? , 2004, European Radiology.

[15]  K. Bae,et al.  Intravenous contrast medium administration and scan timing at CT: considerations and approaches. , 2010, Radiology.