Increasing the signal‐to‐noise ratio in DENSE MRI by combining displacement‐encoded echoes

A new technique was developed to increase the signal‐to‐noise ratio (SNR) in displacement encoding with stimulated echoes (DENSE) MRI. This signal‐averaged DENSE (sav‐DENSE) technique is based on the SNR advantage of extracting a pair of DENSE images with uncorrelated noise from the complex complementary spatial modulation of the magnetization image, and combining them during image reconstruction. Eleven healthy volunteers were imaged at three short‐axis locations with the use of sav‐DENSE, cine DENSE, and myocardial tagging pulse sequences. In this study, sav‐DENSE increased the SNR by 15–34% as compared to cine DENSE. Circumferential strain values measured by sav‐DENSE and myocardial tagging were strongly correlated (slope = 0.95, intercept = –0.02, R = 0.92) and within the 95% limits of agreement. The breath‐hold sav‐DENSE technique yielded relatively accurate and precise quantification of 2D intramyocardial function, with a 40.2‐ms temporal resolution and a 3.5 × 3.5 mm2 spatial resolution. Magn Reson Med 52:188–192, 2004. © 2004 Wiley‐Liss, Inc.

[1]  E. Zerhouni,et al.  Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion. , 1988, Radiology.

[2]  L. Axel,et al.  MR imaging of motion with spatial modulation of magnetization. , 1989, Radiology.

[3]  G. Glover,et al.  Encoding strategies for three‐direction phase‐contrast MR imaging of flow , 1991, Journal of magnetic resonance imaging : JMRI.

[4]  G. Mckinnon Ultrafast interleaved gradient‐echo‐planar imaging on a standard scanner , 1993, Magnetic resonance in medicine.

[5]  S. Maier,et al.  Improved myocardial tagging contrast , 1993, Magnetic resonance in medicine.

[6]  Jerry L. Prince,et al.  Tag and contour detection in tagged MR images of the left ventricle , 1994, IEEE Trans. Medical Imaging.

[7]  P Boesiger,et al.  Limitations of stimulated echo acquisition mode (steam) techniques in cardiac applications , 1995, Magnetic resonance in medicine.

[8]  Jerry L Prince,et al.  Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging , 1999, Magnetic resonance in medicine.

[9]  Jerry L Prince,et al.  Fast determination of regional myocardial strain fields from tagged cardiac images using harmonic phase MRI. , 2000, Circulation.

[10]  H. Wen,et al.  Mixed echo train acquisition displacement encoding with stimulated echoes: An optimized DENSE method for in vivo functional imaging of the human heart , 2001, Magnetic resonance in medicine.

[11]  Jerry L Prince,et al.  Imaging longitudinal cardiac strain on short‐axis images using strain‐encoded MRI , 2001, Magnetic resonance in medicine.

[12]  V. Wedeen,et al.  Simultaneous echo refocusing in EPI , 2002, Magnetic resonance in medicine.

[13]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[14]  F. Epstein,et al.  Importance of k‐space trajectory in echo‐planar myocardial tagging at rest and during dobutamine stress , 2003, Magnetic resonance in medicine.

[15]  Christopher M Kramer,et al.  Myocardial tissue tracking with two-dimensional cine displacement-encoded MR imaging: development and initial evaluation. , 2004, Radiology.

[16]  Demetri Terzopoulos,et al.  Snakes: Active contour models , 2004, International Journal of Computer Vision.