A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities

A technique for producing geometrically accurate magnetic resonance images (MRIs) with undistorted intensity in the face of high levels of static field inhomogeneity arising from either source is presented. The technique requires the acquisition of two images of the same object with altered gradients. On the basis of a knowledge of these gradients it employs an automatic postprocessing step that exploits some invariant characteristics of the distortions to produce a rectified image from the two acquired images. No phantom imaging is involved and no operator interaction is required. The technique is theoretically justified and compared to other techniques, and experimental results that show that the technique works are presented. The improved accuracy in geometry and intensity may improve reliability of stereotactic surgery, may enhance the feasibility of both clinical and industrial imaging via external fields, and may increase the resolution of microscopic imaging.

[1]  Michael A. Malcolm,et al.  Computer methods for mathematical computations , 1977 .

[2]  J. Hutchison,et al.  NMR imaging: image recovery under magnetic fields with large non-uniformities. , 1978, Journal of physics E: Scientific instruments.

[3]  A. Maudsley,et al.  RAPID MEASUREMENT OF MAGNETIC FIELD DISTRIBUTIONS USING NUCLEAR MAGNETIC RESONANCE. , 1979 .

[4]  F. Grund Forsythe, G. E. / Malcolm, M. A. / Moler, C. B., Computer Methods for Mathematical Computations. Englewood Cliffs, New Jersey 07632. Prentice Hall, Inc., 1977. XI, 259 S , 1979 .

[5]  J. R. Singer,et al.  Resolution and signal-to-noise relationships in NMR imaging in the human body. , 1980, Journal of physics E: Scientific instruments.

[6]  L. Kaufman,et al.  Nuclear magnetic resonance imaging in medicine , 1981 .

[7]  Ching-Ming Lai Reconstructing NMR images under magnetic fields with large inhomogeneities , 1982 .

[8]  K. Sekihara,et al.  Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging. , 1984, Physics in medicine and biology.

[9]  Mikio Takagi,et al.  Correction Method Of Image Distortion Due To Non-Uniformity Of Static Magnetic Field In Nmr Imaging , 1984, Other Conferences.

[10]  A. Dwyer,et al.  Frequency Shift Artifacts in MR Imaging , 1985, Journal of computer assisted tomography.

[11]  F. Schmitt Correction of Geometrical Distortions in MR-images , 1985 .

[12]  P. Röschmann,et al.  Susceptibility artefacts in NMR imaging. , 1985, Magnetic resonance imaging.

[13]  P. Bendel Echo Projection Imaging-A Method to Obtain NMR Images Undistorted by Magnetic Field Inhomogeneities , 1985, IEEE Transactions on Medical Imaging.

[14]  M. O’Donnell,et al.  NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. , 1985, Medical physics.

[15]  K. Sekihara,et al.  NMR Imaging for Magnets with Large Nonuniformities , 1985, IEEE Transactions on Medical Imaging.

[16]  M. Takagi,et al.  Estimation of static magnetic field and gradient fields from NMR image , 1986 .

[17]  E. Feig,et al.  Magnetic resonance imaging with non-uniform fields , 1986 .

[18]  Joel B. Miller,et al.  Removal of static field inhomogeneity and chemical-shift effects in NMR imaging , 1986 .

[19]  P. G. Morris,et al.  Nuclear Magnetic Resonance Imaging in Medicine and Biology , 1986 .

[20]  M. R. Willcott,et al.  Magnetic field mapping in NMR imaging. , 1987, Magnetic resonance imaging.

[21]  Tak Sum Wong,et al.  Spin-Inversion Imaging: A Technique for NMR Imaging under Magnetic Fields with High Field Nonuniformities , 1987, IEEE Transactions on Medical Imaging.

[22]  R. Bryan,et al.  MR imaging of susceptibility-induced magnetic field inhomogeneities. , 1988, Radiology.

[23]  J. Hornak,et al.  Magnetic field mapping , 1988, Magnetic resonance in medicine.

[24]  P. M. Walker,et al.  V. Multi-center trial with protocols and prototype test objects for the assessment of MRI equipment , 1988 .

[25]  S. Posse,et al.  Susceptibility artifacts in spin-echo and gradient-echo imaging , 1990 .

[26]  C. Springer,et al.  Bulk magnetic susceptibility shifts in nmr studies of compartmentalized samples: use of paramagnetic reagents , 1990, Magnetic resonance in medicine.

[27]  Y. S. Kwoh,et al.  Correction of distortion of magnetic resonance (MR) pictures for MR-guided robotic stereotactic procedures , 1990 .

[28]  P. Callaghan Susceptibility-limited resolution in nuclear magnetic resonance microscopy , 1990 .