A Non-Contact Measurement System for the Range of Motion of the Hand

An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers.

[1]  P. Lunn,et al.  Fractures of the phalanges: results of internal fixation using 1.5mm and 2mm A. O. screws. , 1987, Journal of hand surgery.

[2]  Anne Bruton,et al.  A study to compare the reliability of composite finger flexion with goniometry for measurement of range of motion in the hand , 2002, Clinical rehabilitation.

[3]  Yafi Levanon,et al.  The advantages and disadvantages of using high technology in hand rehabilitation. , 2013, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[4]  Chris Harris,et al.  Markerless Motion Capture and Measurement of Hand Kinematics: Validation and Application to Home-Based Upper Limb Rehabilitation , 2013, IEEE Transactions on Biomedical Engineering.

[5]  Anne Bruton,et al.  Comparison of Visual Estimation and Goniometry for Assessment of Metacarpophalangeal Joint Angle , 1999 .

[6]  Antonis A. Argyros,et al.  Markerless and Efficient 26-DOF Hand Pose Recovery , 2010, ACCV.

[7]  Frank Weichert,et al.  Analysis of the Accuracy and Robustness of the Leap Motion Controller , 2013, Sensors.

[8]  Alexandra Pfister,et al.  Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis , 2014, Journal of medical engineering & technology.

[9]  Elaine Ewing Fess,et al.  Clinical assessment Recommendations , 1981 .

[10]  D E Cleveland Diagrams for showing limitation of movements through joints, as used by the Board of Pensions Commissioners for Canada. , 1918, Canadian Medical Association journal.

[11]  Sterling Orsten,et al.  Dynamics based 3D skeletal hand tracking , 2013, I3D '13.

[12]  A.F. Frere,et al.  Goniometer based to computer , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[13]  P. Jonsson,et al.  Comparison of measurement accuracy between two types of wrist goniometer systems. , 2001, Applied ergonomics.

[14]  G. Groth,et al.  Goniometry of the proximal and distal interphalangeal joints, Part II: placement prefereces, interrater reliability, and concurrent validity. , 2001, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[15]  Simon A Naji,et al.  Health measurement scales: a practical guide to their development and use (5th edition). , 1990, Australian and New Zealand journal of public health.

[16]  L. Portney,et al.  Foundations of Clinical Research: Applications to Practice , 2015 .

[17]  B Zappa,et al.  A model of an electro-goniometer and its calibration for biomechanical applications. , 2000, Medical engineering & physics.

[18]  Ralph T. Manktelow,et al.  Tendon Function After Replantation: Prognostic Factors and Strategies to Enhance Total Active Motion , 2003, Annals of plastic surgery.

[19]  Rajat Mittal,et al.  Validity and reliability of using photography for measuring knee range of motion: a methodological study , 2011, BMC musculoskeletal disorders.

[20]  Mark A Carey,et al.  Reliability, validity, and clinical usability of a digital goniometer. , 2010, Work.

[21]  Markus Windolf,et al.  Systematic accuracy and precision analysis of video motion capturing systems--exemplified on the Vicon-460 system. , 2008, Journal of biomechanics.

[22]  U. Guzelkucuk,et al.  Comparison of therapeutic activities with therapeutic exercises in the rehabilitation of young adult patients with hand injuries. , 2007, The Journal of hand surgery.

[23]  K. Rome,et al.  A Reliability Study of the Universal Goniometer, Fluid Goniometer, and Electrogoniometer for the Measurement of Ankle Dorsiflexion , 1996, Foot & ankle international.

[24]  J A Blodgett,et al.  Single-mode optical fiber goniometer. , 1992, Optics letters.

[25]  D. Peddle,et al.  A low-cost field and laboratory goniometer system for estimating hyperspectral bidirectional reflectance , 2006 .

[26]  Morey J Kolber,et al.  The reliability and concurrent validity of shoulder mobility measurements using a digital inclinometer and goniometer: a technical report. , 2012, International journal of sports physical therapy.

[27]  M. Ockendon,et al.  Validation of a Novel Smartphone Accelerometer-Based Knee Goniometer , 2012, The Journal of Knee Surgery.

[28]  C. Bombardier,et al.  What do we know about the reliability and validity of physical examination tests used to examine the upper extremity? , 1999, The Journal of hand surgery.

[29]  P T Ali Kitis,et al.  Comparison of two methods of controlled mobilisation of repaired flexor tendons in zone 2 , 2009, Scandinavian journal of plastic and reconstructive surgery and hand surgery.

[30]  Neelesh Kumar,et al.  Evaluation of normal Gait using electro-goniometer , 2009 .

[31]  Elia Palange,et al.  A New Flexible Optical Fiber Goniometer for Dynamic Angular Measurements: Application to Human Joint Movement Monitoring , 2008, IEEE Transactions on Instrumentation and Measurement.

[32]  Joanna Kvist,et al.  Interrater reliability in finger joint goniometer measurement in Dupuytren's disease. , 2012, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[33]  M. Muhlenhaupt Measurement of Joint Motion: A Guide to Goniometry , 1986 .

[34]  Ralf Dresner,et al.  Health Measurement Scales A Practical Guide To Their Development And Use , 2016 .

[35]  G. Allison,et al.  Validation of the spin-T goniometer, a cervical range of motion device. , 2005, Journal of manipulative and physiological therapeutics.

[36]  M. Mullaney,et al.  Reliability of shoulder range of motion comparing a goniometer to a digital level , 2010, Physiotherapy theory and practice.

[37]  William D. Bandy,et al.  Joint Range of Motion and Muscle Length Testing , 2009 .

[38]  A A Gabel,et al.  Fractures of the phalanges. , 1983, The Veterinary clinics of North America. Large animal practice.

[39]  Karan Singh,et al.  Eurographics/siggraph Symposium on Computer Animation (2003) Handrix: Animating the Human Hand , 2003 .

[40]  W Kowsuwon,et al.  Axial Rotation Gravity Goniometer: A Simple Design of Instrument and a Controlled Reliability Study , 1990, Clinical orthopaedics and related research.