A numerical study of pulsatile blood flow in an eccentric catheterized artery using a fast algorithm

The pulsatile blood flow in an eccentric catheterized artery is studied numerically by making use of an extended version of the fast algorithm of Borges and Daripa [J. Comp. Phys., 2001]. The mathematical model involves the usual assumptions that the arterial segment is straight, the arterial wall is rigid and impermeable, blood is an incompressible Newtonian fluid, and the flow is fully developed. The flow rate (flux) is considered as a periodic function of time (prescribed). The axial pressure gradient and velocity distribution in the eccentric catheterized artery are obtained as solutions of the problem. Through the computed results on axial pressure gradient, the increases in mean pressure gradient and frictional resistance in the artery due to catheterization are estimated. These estimates can be used to correct the error involved in the measured pressure gradients using catheters.

[1]  Prabir Daripa,et al.  Singular integral transforms and fast numerical algorithms , 1998, Numerical Algorithms.

[2]  S. M. Collins,et al.  The effect of coronary angioplasty on coronary flow reserve. , 1988, Circulation.

[3]  D. A. Mcdonald Blood flow in arteries , 1974 .

[4]  W. T. Snyder,et al.  An analysis of fully developed laminar flow in an eccentric annulus , 1965 .

[5]  G. Jayaraman,et al.  Numerical study of flow in a constricted curved annulus: An application to flow in a catheterised artery , 2001 .

[6]  L. Back,et al.  Flow rate-pressure drop relation in coronary angioplasty: catheter obstruction effect. , 1996, Journal of biomechanical engineering.

[7]  Rodney A. White,et al.  Hemodynamic Consequences of Stenosis Remodeling During Coronary Angioplasty , 1997, Angiology.

[8]  H. Pettersson,et al.  Hydro- and Hemodynamic Effects of Catheterization of Vessels , 1977, Acta radiologica: diagnosis.

[9]  Fully developed incompressible flow between non-coaxial circular cylinders , 1982 .

[10]  Prabir Daripa A Fast Algorithm to Solve Nonhomogeneous Cauchy-Riemann Equations in the Complex Plane , 1992, SIAM J. Sci. Comput..

[11]  H. Pettersson,et al.  Hydro- and Hemodynamic Effects of Catheterization of Vessels , 1977, Acta radiologica: diagnosis.

[12]  G Jayaraman,et al.  Flow in a catheterized curved artery with stenosis. , 1999, Journal of biomechanics.

[13]  G Jayaraman,et al.  Estimation of increased flow resistance in a narrow catheterized artery--a theoretical model. , 1996, Journal of biomechanics.

[14]  John B. Shoven,et al.  I , Edinburgh Medical and Surgical Journal.

[15]  H V Anderson,et al.  Measurement of transstenotic pressure gradient during percutaneous transluminal coronary angioplasty. , 1986, Circulation.

[16]  H. Pettersson,et al.  Hydro- and Hemodynamic Effects of Catheterization of Vessels , 1976, Acta radiologica: diagnosis.

[17]  J. D. Garnic,et al.  Usefulness of transstenotic coronary pressure gradient measurements during diagnostic catheterization. , 1985, The American journal of cardiology.

[18]  L. Back,et al.  Estimated mean flow resistance increase during coronary artery catheterization. , 1994, Journal of biomechanics.

[19]  D. A. MacDonald Pulsatile flow in a catheterised artery. , 1986, Journal of biomechanics.

[20]  G Jayaraman,et al.  Correction to flow rate--pressure drop relation in coronary angioplasty: steady streaming effect. , 1998, Journal of biomechanics.

[21]  H. Pettersson,et al.  Hydro- and Hemodynamic Effects of Catheterization of Vessels , 1976, Acta radiologica: diagnosis.

[22]  G. Karahalios Some possible effects of a catheter on the arterial wall. , 1990, Medical physics.

[23]  Prabir Daripa,et al.  A fast parallel algorithm for the Poisson equation on a disk , 2001 .