EBRA improves the accuracy of radiographic analysis of acetabular cup migration.

EBRA (Ein Bild Röntgen Analyse) is a new computerized method measuring migration and wear of the acetabular cup, suggested to improve measurement accuracy. We evaluated possible errors of measurement and compared EBRA with standard methods. 1. We did repeated measurements on a single radiograph using the same reference lines. The reliability of the input procedure with standard measurements was significantly better than repeated digitization with EBRA. 2. In a more clinical test, a group of 10 patients was studied. 5 radiographs were taken of the same patient on the same day. EBRA improved the reliability of repeated radiographic examination significantly for migration measurements in the vertical direction. 3. To assess the inter- and intraobserver variations, repeated measurements were performed on the clinical series of pelvic radiographs of 10 patients. EBRA was significantly better than standard methods. With EBRA, errors of wear and migration measurements could be reduced, as compared to standard methods. The major improvement with EBRA was found for migration measurements in the vertical direction.

[1]  R Bauer,et al.  Early migration predicts late aseptic failure of hip sockets. , 1996, The Journal of bone and joint surgery. British volume.

[2]  B. Mjöberg Loosening of the cemented hip prosthesis , 1986 .

[3]  G. Selvik Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. , 1989, Acta orthopaedica Scandinavica. Supplementum.

[4]  R Bauer,et al.  EBRA: a method to measure migration of acetabular components. , 1995, Journal of biomechanics.

[5]  T. Ilchmann,et al.  Measurement accuracy in acetabular cup wear. Three retrospective methods compared with Roentgen stereophotogrammetry. , 1995, The Journal of arthroplasty.

[6]  T. Ilchmann,et al.  Measurement accuracy in acetabular cup migration. A comparison of four radiologic methods versus roentgen stereophotogrammetric analysis. , 1992, The Journal of arthroplasty.

[7]  D W Hukins,et al.  Measurement of hip prostheses using image analysis. The maxima hip technique. , 1991, The Journal of bone and joint surgery. British volume.

[8]  M A Freeman,et al.  Acetabular cup migration. Prediction of aseptic loosening. , 1995, The Journal of bone and joint surgery. British volume.

[9]  U. Bengnér,et al.  Socket migration after Charnley arthroplasty in rheumatoid arthritis and osteoarthritis. A roentgen stereophotogrammetric study. , 1993, The Journal of bone and joint surgery. British volume.

[10]  B. Morrey,et al.  Effect of femoral head size on wear of the polyethylene acetabular component. , 1990, The Journal of bone and joint surgery. American volume.

[11]  M A Freeman,et al.  The measurement of migration of the acetabular component of hip prostheses. , 1989, The Journal of bone and joint surgery. British volume.

[12]  E KALLIO,et al.  Injuries of the thoraco-lumbar spine with paraplegia. , 1963, Acta orthopaedica Scandinavica. Supplementum.

[13]  J Kärrholm,et al.  Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients. , 1995, Acta orthopaedica Scandinavica.

[14]  G Markhede,et al.  Extra-abdominal desmoid tumors. , 1986, Acta orthopaedica Scandinavica.

[15]  B. Mjöberg Loosening of the cemented hip prosthesis. The importance of heat injury. , 1986, Acta orthopaedica Scandinavica. Supplementum.