Damping Methods for Resonances Caused by LCL-Filter-Based Current-Controlled Grid-Tied Power Inverters: An Overview

Grid-tied voltage source inverters using LCL filter have been widely adopted in distributed power generation systems (DPGSs). As high-order LCL filters contain multiple resonant frequencies, switching harmonics generated by the inverter and current harmonics generated by the active/passive loads would cause the system resonance, and thus the output current distortion and oscillation. Such phenomenon is particularly critical when the power grid is weak with the unknown grid impedance. In order to stabilize the operation of the DPGS and improve the waveform of the injected currents, many innovative damping methods have been proposed. A comprehensive overview on those contributions and their classification on the inverter- and grid-side damping measures are presented. Based on the concept of the impedance-based stability analysis, all damping methods can ensure the system stability by modifying the effective output impedance of the inverter or the effective grid impedance. Classical damping methods for industrial applications will be analyzed and compared. Finally, the future trends of the impedance-based stability analysis, as well as some promising damping methods, will be discussed.

[1]  Weidong Xiao,et al.  Two Degrees of Freedom Active Damping Technique for $LCL$ Filter-Based Grid Connected PV Systems , 2014, IEEE Transactions on Industrial Electronics.

[2]  Juan C. Vasquez,et al.  Selective Harmonic-Compensation Control for Single-Phase Active Power Filter With High Harmonic Rejection , 2009, IEEE Transactions on Industrial Electronics.

[3]  Yun Wei Li,et al.  Distribution System Harmonic Compensation Methods: An Overview of DG-Interfacing Inverters , 2014, IEEE Industrial Electronics Magazine.

[4]  R. D. Middlebrook,et al.  Input filter considerations in design and application of switching regulators. , 1976 .

[5]  P.J.M. Heskes,et al.  Harmonic interaction between a large number of distributed power inverters and the distribution network , 2004, IEEE Transactions on Power Electronics.

[6]  Kai Zhang,et al.  A Time Delay Compensation Method Based on Area Equivalence For Active Damping of an LCL -Type Converter , 2017, IEEE Transactions on Power Electronics.

[7]  Bin Wu,et al.  Resonance Damping and Harmonic Suppression for Grid-Connected Current-Source Converter , 2014, IEEE Transactions on Industrial Electronics.

[8]  P. Rodriguez,et al.  Online grid impedance estimation for single-phase grid-connected systems using PQ variations , 2007, 2007 IEEE Power Electronics Specialists Conference.

[9]  Alex Huang,et al.  Solid state transformer in the future smart electrical system , 2013, 2013 IEEE Power & Energy Society General Meeting.

[10]  Bo Wen,et al.  Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters , 2016, IEEE Transactions on Power Electronics.

[11]  Frede Blaabjerg,et al.  Virtual RC Damping of LCL-Filtered Voltage Source Converters With Extended Selective Harmonic Compensation , 2015, IEEE Transactions on Power Electronics.

[12]  Henry Shu-Hung Chung,et al.  Modified Cascaded Boundary-Deadbeat Control for a Virtually-Grounded Three-Phase Grid-Connected Inverter With LCL Filter , 2017, IEEE Transactions on Power Electronics.

[13]  Bo Wen Stability Analysis of Three-Phase AC Power Systems Based on Measured D-Q Frame Impedances , 2015 .

[14]  Marco Liserre,et al.  Systematic Design of the Lead-Lag Network Method for Active Damping in LCL-Filter Based Three Phase Converters , 2014, IEEE Transactions on Industrial Informatics.

[15]  Yuanbin He,et al.  A new passive filter design method for overvoltage suppression and bearing currents mitigation in a long cable based PWM inverter-fed motor drive system , 2017, 2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia).

[16]  Nilanjan Mukherjee,et al.  Analysis and improvement of performance in LCL filter-based PWM rectifier/inverter application using hybrid damping approach , 2013 .

[17]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[18]  F. Blaabjerg,et al.  An LLCL Power Filter for Single-Phase Grid-Tied Inverter , 2012, IEEE Transactions on Power Electronics.

[19]  Henry Shu-hung Chung,et al.  Direct Current Tracking Using Boundary Control With Second-Order Switching Surface for Three-Phase Three-Wire Grid-Connected Inverter , 2017, IEEE Transactions on Power Electronics.

[20]  Jian Sun,et al.  Input Impedance Modeling of Multipulse Rectifiers by Harmonic Linearization , 2009, IEEE Transactions on Power Electronics.

[21]  Jian Sun,et al.  Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters , 2014, IEEE Transactions on Power Electronics.

[22]  Poh Chiang Loh,et al.  Exploring inherent damping characteristic of LCL-filters for three-phase grid-connected voltage source inverters , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[23]  Rui Li,et al.  Influence of Delay on System Stability and Delay Optimization of Grid-Connected Inverters With LCL Filter , 2014, IEEE Transactions on Industrial Informatics.

[24]  Yun Wei Li,et al.  Hybrid Voltage and Current Control Approach for DG-Grid Interfacing Converters With LCL filters , 2013, IEEE Transactions on Industrial Electronics.

[25]  Ilhem Slama-Belkhodja,et al.  Easy and Fast Sensor Fault Detection and Isolation Algorithm for Electrical Drives , 2012, IEEE Transactions on Power Electronics.

[26]  Yun Wei Li,et al.  Analysis and Mitigation of Resonance Propagation in Grid-Connected and Islanding Microgrids , 2015, IEEE Transactions on Energy Conversion.

[27]  Xinbo Ruan,et al.  Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor–Current-Feedback Active-Damping , 2014 .

[28]  Necmi Altin,et al.  Lyapunov-Function and Proportional-Resonant-Based Control Strategy for Single-Phase Grid-Connected VSI With LCL Filter , 2016, IEEE Transactions on Industrial Electronics.

[29]  Marco Liserre,et al.  Integrated voltage control and line congestion management in Active Distribution Networks by means of smart transformers , 2014, 2014 IEEE 23rd International Symposium on Industrial Electronics (ISIE).

[30]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[31]  Hirofumi Akagi,et al.  Stability analysis of a series active filter integrated with a double-series diode rectifier , 2000, 2000 IEEE 31st Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.00CH37018).

[32]  Jih-Sheng Lai,et al.  Derivation, Analysis, and Implementation of a Boost–Buck Converter-Based High-Efficiency PV Inverter , 2012, IEEE Transactions on Power Electronics.

[33]  Bangyin Liu,et al.  Stability Analysis of Grid-Connected Inverter With LCL Filter Adopting a Digital Single-Loop Controller With Inherent Damping Characteristic , 2013, IEEE Transactions on Industrial Informatics.

[34]  J L Agorreta,et al.  Modeling and Control of $N$ -Paralleled Grid-Connected Inverters With LCL Filter Coupled Due to Grid Impedance in PV Plants , 2011, IEEE Transactions on Power Electronics.

[35]  Frede Blaabjerg,et al.  Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System , 2014, IEEE Transactions on Power Electronics.

[36]  Fred C. Lee,et al.  Impedance specifications for stable DC distributed power systems , 2002 .

[37]  Frede Blaabjerg,et al.  An Active Damper for Stabilizing Power-Electronics-Based AC Systems , 2014 .

[38]  Deyu Wang,et al.  Real-time grid impedance estimation technique for grid-connected power converters , 2012, 2012 IEEE International Symposium on Industrial Electronics.

[39]  Yun Wei Li,et al.  A Flexible Harmonic Control Approach Through Voltage-Controlled DG–Grid Interfacing Converters , 2012, IEEE Transactions on Industrial Electronics.

[40]  Jinjun Liu,et al.  Infinity-Norm of Impedance-Based Stability Criterion for Three-Phase AC Distributed Power Systems With Constant Power Loads , 2015, IEEE Transactions on Power Electronics.

[41]  Frede Blaabjerg,et al.  An Efficient and Robust Hybrid Damper for $LCL$- or $LLCL$-Based Grid-Tied Inverter With Strong Grid-Side Harmonic Voltage Effect Rejection , 2016, IEEE Transactions on Industrial Electronics.

[42]  Bo Wen,et al.  Inverse Nyquist Stability Criterion for Grid-Tied Inverters , 2017, IEEE Transactions on Power Electronics.

[43]  Frede Blaabjerg,et al.  Voltage and current balancing in Low and Medium Voltage grid by means of Smart Transformer , 2015, 2015 IEEE Power & Energy Society General Meeting.

[44]  P. Rodriguez,et al.  Line Impedance Estimation Using Active and Reactive Power Variations , 2007, 2007 IEEE Power Electronics Specialists Conference.

[45]  Dong-Choon Lee,et al.  Resonance Suppression Based on PR Control for Single-Phase Grid-Connected Inverters With $LLCL$ Filters , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[46]  Jinjun Liu,et al.  Stability Issues of $Z + Z$ Type Cascade System in Hybrid Energy Storage System (HESS) , 2014, IEEE Transactions on Power Electronics.

[47]  Marija D. Ilic,et al.  Dynamics and control of large electric power systems , 2000 .

[48]  Frede Blaabjerg,et al.  A Review of Passive Power Filters for Three-Phase Grid-Connected Voltage-Source Converters , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[49]  Xinbo Ruan,et al.  Small-Signal Modeling and Parameters Design for Virtual Synchronous Generators , 2016, IEEE Transactions on Industrial Electronics.

[50]  Marko Hinkkanen,et al.  State Observer for Grid-Voltage Sensorless Control of a Converter Equipped With an LCL Filter: Direct Discrete-Time Design , 2016, IEEE Transactions on Industry Applications.

[51]  Jian Sun,et al.  Online Grid Impedance Measurement Using Discrete-Interval Binary Sequence Injection , 2013, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[52]  Frede Blaabjerg,et al.  Design and Analysis of Robust Active Damping for LCL Filters Using Digital Notch Filters , 2017, IEEE Transactions on Power Electronics.

[53]  Frede Blaabjerg,et al.  A Modified LLCL Filter With the Reduced Conducted EMI Noise , 2013, IEEE Transactions on Power Electronics.

[54]  Francisco D. Freijedo,et al.  A Method for Identification of the Equivalent Inductance and Resistance in the Plant Model of Current-Controlled Grid-Tied Converters , 2015, IEEE Transactions on Power Electronics.

[55]  Frede Blaabjerg,et al.  Aalborg Inverter - A New Type of “Buck in Buck, Boost in Boost” Grid-Tied Inverter , 2015, IEEE Transactions on Power Electronics.

[56]  Bo Wen,et al.  Small-Signal Stability Analysis of Three-Phase AC Systems in the Presence of Constant Power Loads Based on Measured d-q Frame Impedances , 2015, IEEE Transactions on Power Electronics.

[57]  Marco Liserre,et al.  Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter , 2011, IEEE Transactions on Industrial Electronics.

[58]  Daniel Pizarro-Perez,et al.  Grid Impedance Monitoring System for Distributed Power Generation Electronic Interfaces , 2009, IEEE Transactions on Instrumentation and Measurement.

[59]  Yan Zhou,et al.  Parameter Design of a Two-Current-Loop Controller Used in a Grid-Connected Inverter System With LCL Filter , 2009, IEEE Transactions on Industrial Electronics.

[60]  Dushan Boroyevich,et al.  Novel reduced-order small-signal model of a three-phase PWM rectifier and its application in control design and system analysis , 1996 .

[61]  Xinbo Ruan,et al.  A Real-Time Computation Method With Dual Sampling Mode to Improve the Current Control Performance of the $LCL$-Type Grid-Connected Inverter , 2015, IEEE Transactions on Industrial Electronics.

[62]  Frede Blaabjerg,et al.  Generalized stability regions of current control for LCL-filtered grid-connected converters without passive or active damping , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[63]  Marco Liserre,et al.  Operation and control of smart transformer for improving performance of medium voltage power distribution system , 2015, 2015 IEEE 6th International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[64]  M. L. Crow,et al.  Stability Design Criteria for Distribution Systems With Solid-State Transformers , 2014, IEEE Transactions on Power Delivery.

[65]  H. Akagi,et al.  A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[66]  Hirofumi Akagi Control Strategy and Site Selection of a Shunt Active Filter for Damping of Harmonic Propagation in Power Distribution Systems , 1997 .

[67]  Tzung-Lin Lee,et al.  Discrete Frequency Tuning Active Filter for Power System Harmonics , 2009, IEEE Transactions on Power Electronics.

[68]  Steffan Hansen,et al.  Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters , 2010, IEEE Transactions on Industry Applications.

[69]  Frede Blaabjerg,et al.  Active Damping of LLCL-Filter Resonance Based on LC-Trap Voltage or Current Feedback , 2016, IEEE Transactions on Power Electronics.

[70]  D. Borkowski,et al.  Estimation of power system parameters based on load variance observations - laboratory studies , 2007, 2007 9th International Conference on Electrical Power Quality and Utilisation.

[71]  Donald Grahame Holmes,et al.  Regions of active damping control for LCL filters , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[72]  Rolando Burgos,et al.  Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems , 2013, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[73]  Wei Xu,et al.  New Hybrid Damping Strategy for Grid-Connected Photovoltaic Inverter With LCL Filter , 2014, IEEE Transactions on Applied Superconductivity.

[74]  Miguel Castilla,et al.  Control of Power Converters in AC Microgrids , 2018, Microgrids Design and Implementation.

[75]  Vinod John,et al.  Analysis and design of split-capacitor resistive-inductive passive damping for LCL filters in grid-connected inverters , 2013 .

[76]  Frede Blaabjerg,et al.  A New Design Method for the Passive Damped LCL and LLCL Filter-Based Single-Phase Grid-Tied Inverter , 2013, IEEE Transactions on Industrial Electronics.

[77]  P. Kundur,et al.  Power system stability and control , 1994 .

[78]  Jiyan Zou,et al.  Delay-Dependent Stability of Single-Loop Controlled Grid-Connected Inverters with LCL Filters , 2016, IEEE Transactions on Power Electronics.

[79]  F. Blaabjerg,et al.  Online grid measurement and ENS detection for PV inverter running on highly inductive grid , 2004, IEEE Power Electronics Letters.

[80]  C. Xia,et al.  Wide Damping Region for LCL-Type Grid-Connected Inverter With an Improved Capacitor-Current-Feedback Method , 2015, IEEE Transactions on Power Electronics.

[81]  K. Wada,et al.  Considerations of a shunt active filter based on voltage detection for installation on a long distribution feeder , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[82]  Fei Wang,et al.  Wind Energy System With Integrated Functions of Active Power Transfer, Reactive Power Compensation, and Voltage Conversion , 2013, IEEE Transactions on Industrial Electronics.

[83]  Shuai Jiang,et al.  Resonance Issues and Damping Techniques for Grid-Connected Inverters With Long Transmission Cable , 2014, IEEE Transactions on Power Electronics.

[84]  Zhe Chen,et al.  Site Selection Strategy of Single-Frequency Tuned R-APF for Background Harmonic Voltage Damping in Power Systems , 2013, IEEE Transactions on Power Electronics.

[85]  J. A. Solsona,et al.  Control Strategy of a DVR to Improve Stability in Wind Farms Using Squirrel-Cage Induction Generators , 2011, IEEE Transactions on Power Systems.

[86]  Frede Blaabjerg,et al.  Highly Accurate Derivatives for LCL-Filtered Grid Converter With Capacitor Voltage Active Damping , 2016, IEEE Transactions on Power Electronics.

[87]  Frede Blaabjerg,et al.  A series-LC-filtered active damper for ac power electronics based power systems , 2015, 2015 IEEE Applied Power Electronics Conference and Exposition (APEC).

[88]  Frede Blaabjerg,et al.  A Dual-Buck–Boost AC/DC Converter for DC Nanogrid With Three Terminal Outputs , 2017, IEEE Transactions on Industrial Electronics.

[89]  Nils Hoffmann,et al.  Minimal Invasive Equivalent Grid Impedance Estimation in Inductive–Resistive Power Networks Using Extended Kalman Filter , 2014, IEEE Transactions on Power Electronics.

[90]  E.J. Bueno,et al.  Complex-space recursive least squares power system identification , 2007, 2007 IEEE Power Electronics Specialists Conference.

[91]  Huai Wang,et al.  A Robust Passive Damping Method for LLCL-Filter-Based Grid-Tied Inverters to Minimize the Effect of Grid Harmonic Voltages , 2014, IEEE Transactions on Power Electronics.

[92]  I. Slama-Belkhodja,et al.  Online detection and estimation of grid impedance variation for Distributed Power Generation , 2012, 2012 16th IEEE Mediterranean Electrotechnical Conference.

[93]  Frede Blaabjerg,et al.  Grid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source Converters , 2016, IEEE Transactions on Power Electronics.

[94]  Frede Blaabjerg,et al.  Self-commissioning notch filter for active damping in three phase LCL-filter based grid converters , 2013, 2013 15th European Conference on Power Electronics and Applications (EPE).

[95]  Qing-Chang Zhong,et al.  Synchronverters: Inverters That Mimic Synchronous Generators , 2011, IEEE Transactions on Industrial Electronics.

[96]  P. Mattavelli,et al.  Analysis of Multisampled Current Control for Active Filters , 2007, IEEE Transactions on Industry Applications.

[97]  Jia Liu,et al.  Comparison of Dynamic Characteristics Between Virtual Synchronous Generator and Droop Control in Inverter-Based Distributed Generators , 2016, IEEE Transactions on Power Electronics.

[98]  Jian Sun,et al.  Impedance-Based Stability Criterion for Grid-Connected Inverters , 2011, IEEE Transactions on Power Electronics.

[99]  Johann W. Kolar,et al.  Shifting input filter resonances - An intelligent converter behavior for maintaining system stability , 2010, The 2010 International Power Electronics Conference - ECCE ASIA -.

[100]  Niels Kjølstad Poulsen,et al.  Short-circuit impedance measurement , 2003 .

[101]  Xinbo Ruan,et al.  Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter , 2014, IEEE Transactions on Power Electronics.

[102]  M. Liserre,et al.  Grid Impedance Estimation via Excitation of $LCL$ -Filter Resonance , 2007, IEEE Transactions on Industry Applications.

[103]  D. G. Holmes,et al.  Optimized Design of Stationary Frame Three Phase AC Current Regulators , 2009, IEEE Transactions on Power Electronics.

[104]  M. Liserre,et al.  Analysis of the Passive Damping Losses in LCL-Filter-Based Grid Converters , 2013, IEEE Transactions on Power Electronics.

[105]  M. Belkhayat,et al.  Stability criteria for AC power systems with regulated loads , 1997 .

[106]  Xinbo Ruan,et al.  Optimized Controller Design for $LCL$-Type Grid-Connected Inverter to Achieve High Robustness Against Grid-Impedance Variation , 2015, IEEE Transactions on Industrial Electronics.

[107]  Remus Teodorescu,et al.  Line impedance estimation using model based identification technique , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.

[108]  Alfred Rufer,et al.  High-Order Vector Control of Grid-Connected Voltage-Source Converters With LCL-Filters , 2014, IEEE Transactions on Industrial Electronics.

[109]  Frede Blaabjerg,et al.  Optimal Design of High-Order Passive-Damped Filters for Grid-Connected Applications , 2016, IEEE Transactions on Power Electronics.

[110]  Frede Blaabjerg,et al.  A Self-commissioning Notch Filter for Active Damping in a Three-Phase LCL -Filter-Based Grid-Tie Converter , 2014, IEEE Transactions on Power Electronics.

[111]  H. Akagi,et al.  Hybrid and Series Active Filters , 2007 .

[112]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).