Imaging performance of attenuated phase-shift mask using coherent scattering microscope

The half-tone phase shift mask (PSM) has been suggested for better imaging performances like image contrast, NILS and H-V bias compared to the binary mask (BIM) in EUV lithography. In this paper, we measured imaging performance of a fabricated half-tone attenuated PSM with Coherent Scattering Microscopy (CSM) and the results were compared with simulation data obtained by EM-suite tool. We prepared a half-tone attenuated PSM which has 12.7% reflectivity and 180° phase shift with absorber stack of 16.5mn-thick TaN absorber and 24nm-thick Mo phase shifter. With CSM, an actinic inspection tool, we measured the imaging properties of PSM. The diffraction efficiencies of BIM were measured as 31%, 36%, and 44% for 88 nm, 100 nm, and 128 nm mask CD, respectively, while those of PSM were measured as 45%, 62%, and 81%. Also the aerial image at wafer level obtained by CSM with high volume manufacturing tool’s (HVM) illumination condition (NA=0.33, σ=0.9) showed higher image contrast and NILS with phase shift effect. And the measured data were consistent with the simulation data.

[1]  I. Nishiyama,et al.  Effect of incident angle of off-axis illumination on pattern printability in extreme ultraviolet lithography , 2003 .

[2]  J. Miao,et al.  Phase retrieval of diffraction patterns from noncrystalline samples using the oversampling method , 2003 .

[3]  S. Hädrich,et al.  Lensless diffractive imaging using tabletop coherent high-harmonic soft-X-ray beams. , 2007, Physical review letters.

[4]  Toshihiko Tanaka,et al.  Actinic Phase Defect Detection for Extreme Ultraviolet Lithography Mask with Absorber Patterns , 2010 .

[5]  Kenneth A. Goldberg,et al.  Actinic characterization of extreme ultraviolet bump-type phase defects , 2011 .

[6]  J. Miao,et al.  Phase retrieval from the magnitude of the Fourier transforms of nonperiodic objects , 1998 .

[7]  Hiroo Kinoshita,et al.  Study on critical dimension of printable phase defects using an EUV microscope , 2009 .

[8]  K. Goldberg,et al.  Actinic imaging and evaluation of phase structures on extreme ultraviolet lithography masks , 2010 .

[9]  Sangsul Lee,et al.  Improved imaging properties of thin attenuated phase shift masks for extreme ultraviolet lithography , 2013 .

[10]  Kenneth A. Goldberg,et al.  Actinic extreme ultraviolet mask inspection beyond 0.25numericalaperture , 2008 .

[11]  H. Takajo,et al.  Reconstruction of an object from its noisy Fourier modulus: ideal estimate of the object to be reconstructed and a method that attempts to find that estimate. , 1999, Applied optics.

[12]  Jingjuan Zhang,et al.  Phase-retrieval algorithms applied in a 4-f system for optical image encryption: a comparison , 2005, SPIE/COS Photonics Asia.

[13]  Yuya Yamaguchi,et al.  Imaging Performance Improvement of an Extreme Ultraviolet Microscope , 2010 .

[14]  Gregory J. Tallents,et al.  Optical lithography: Lithography at EUV wavelengths , 2010 .

[15]  Takeo Watanabe,et al.  Critical Dimension Measurement of an Extreme-Ultraviolet Mask Utilizing Coherent Extreme-Ultraviolet Scatterometry Microscope at NewSUBARU , 2011 .

[16]  Jianwei Miao,et al.  High resolution 3-D X-ray diffraction microscopy and its potential of imaging single biomolecules , 2002 .

[17]  Sangsul Lee,et al.  Effect of Attenuated Phase Shift Mask Structure on Extreme Ultraviolet Lithography , 2009 .