Bond capacity of severely corroded bars with corroded stirrups

Eccentric pull-out tests were carried out to study the influence of severe corrosion leading to extensive cover cracking, and the effect of corroded and non-corroded stirrups on the anchorage of deformed bars. The specimens were subjected to a low-rate electrochemical corrosion process for three time spans that caused a rebar weight loss up to approximately 20% in the main bars and 35% in the stirrups. Pull-out tests were then carried out in each specimen, on either the two corner bars or the middle bar, to measure the bond capacity. The effects of corrosion and the mechanical testing were simulated with non-linear finite-element analysis. The combination of tests and analyses gives a better understanding of the effect of high corrosion penetrations and the presence of corroded Stirrups on failure modes. The presence of stirrups, corroded and non-corroded, was found to significantly change the behavior of an anchorage region, namely the corrosion-induced crack pattern, the failure mode and the bond capacity.

[1]  Irina Vasiljeva Sæther,et al.  Bond deterioration of corroded steel bars in concrete , 2011 .

[2]  Paul E. Regan,et al.  ASSESSMENT OF CONCRETE STRUCTURES AFFECTED BY COVER DELAMINATION. PART 1: EFFECT OF BOND LOSS , 2009 .

[3]  Surendra P. Shah,et al.  Comparison of Two Accelerated Corrosion Techniques for Concrete Structures , 2007 .

[4]  Richard E. Weyers,et al.  MODELING THE TIME-TO-CORROSION CRACKING IN CHLORIDE CONTAMINATED REINFORCED CONCRETE STRUCTURES , 1998 .

[5]  M. Berra,et al.  Steel-concrete bond deterioration due to corrosion: finite-element analysis for different confinement levels , 2003 .

[6]  Per Kettil,et al.  Effects on bond of reinforcement corrosion , 2007 .

[7]  Karin Lundgren,et al.  Bond between ribbed bars and concrete. Part 2: The effect of corrosion , 2005 .

[8]  K. Lundgren,et al.  Corrosion influence on bond in reinforced concrete , 2004 .

[9]  Kamyab Zandi Hanjari Load-Carrying Capacity of Damaged Concrete Structures , 2008 .

[10]  D. Hordijk Local approach to fatigue of concrete , 1991 .

[11]  K. Lundgren,et al.  Modelling the effect of corrosion on bond in reinforced concrete , 2002 .

[12]  Abul K. Azad,et al.  Residual strength of corrosion-damaged reinforced concrete beams , 2007 .

[13]  E. Thorenfeldt Mechanical properties of high-strength concrete and applications in design , 1987 .

[14]  Kent Gylltoft,et al.  A MODEL FOR THE BOND BETWEEN CONCRETE AND REINFORCEMENT , 2000 .

[15]  Karin Lundgren,et al.  Bond between ribbed bars and concrete. Part 1: Modified model , 2005 .

[16]  P. Bowen,et al.  Changes in portlandite morphology with solvent composition: Atomistic simulations and experiment , 2011 .

[17]  Paul E. Regan,et al.  Shear strength of RC beams with defective stirrup anchorages , 2004 .

[18]  Cruz Alonso,et al.  Cover cracking as a function of rebar corrosion: Part 2—Numerical model , 1993 .

[19]  Takafumi Noguchi,et al.  Evaluation of the bond properties between concrete and reinforcement as a function of the degree of reinforcement corrosion , 2002 .

[20]  Dario Coronelli,et al.  Structural Assessment of Corroded Reinforced Concrete Beams: Modeling Guidelines , 2004 .

[21]  Kapilesh Bhargava,et al.  Model for cover cracking due to rebar corrosion in RC structures , 2006 .

[22]  Rasheeduzzafar,et al.  EFFECT OF REINFORCEMENT CORROSION ON BOND STRENGTH , 1996 .

[23]  Jonas Magnusson,et al.  Bond and Anchorage of Ribbed Bars in High-Strength Concrete , 2000 .

[24]  William C Farrow,et al.  Tests of Reinforced Concrete Beams with Corrosion-Damaged Stirrups , 2006 .