The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer.

Stereotactic body radiation therapy (SBRT), which delivers a much higher fractional dose than conventional treatment in only a few fractions, is an effective treatment for liver metastases. For patients who are treated under free-breathing conditions, however, respiration-induced tumor motion in the liver is a concern. Limited clinical information is available related to the impact of tumor motion and treatment technique on the dosimetric consequences. This study evaluated the dosimetric deviations between planned and delivered SBRT dose in the presence of tumor motion for three delivery techniques: three-dimensional conformal static beams (3DCRT), dynamic conformal arc (DARC), and intensity-modulated radiation therapy (IMRT). Five cases treated with SBRT for liver metastases were included in the study, with tumor motions ranging from 0.5 to 1.75 cm. For each case, three different treatment plans were developed using 3DCRT, DARC, and IMRT. The gantry/multileaf collimator (MLC) motion in the DARC plans and the MLC motion in the IMRT plans were synchronized to the patient's respiratory motion. Retrospectively sorted four-dimensional computed tomography image sets were used to determine patient-organ motion and to calculate the dose delivered during each respiratory phase. Deformable registration, using thin-plate-spline models, was performed to encode the tumor motion and deformation and to register the dose-per-phase to the reference phase images. The different dose distributions resulting from the different delivery techniques and motion ranges were compared to assess the effect of organ motion on dose delivery. Voxel dose variations occurred mostly in the high gradient regions, typically between the target volume and normal tissues, with a maximum variation up to 20%. The greatest CTV variation of all the plans was seen in the IMRT technique with the largest motion range (D99: -8.9%, D95: -8.3%, and D90: -6.3%). The greatest variation for all 3DCRT plans was less than 2% for D95. Dose variations for DARC fell between the 3DCRT and IMRT techniques. The dose volume histogram variations for normal organs were negligible. Therefore, the IMRT technique may be a preferable treatment choice in cases where the target volume and critical organs are in close proximity, or when normal organ protection is a high priority, provided that motion effect for the target volume can be managed.

[1]  Randall K Ten Haken,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: sensitivity to variations in motion. , 2003, Medical physics.

[2]  Steve Webb,et al.  Quantifying the effect of respiratory motion on lung tumour dosimetry with the aid of a breathing phantom with deforming lungs , 2006, Physics in medicine and biology.

[3]  Y D Mutaf,et al.  The impact of temporal inaccuracies on 4DCT image quality. , 2007, Medical physics.

[4]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[5]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[6]  Tinsu Pan,et al.  Four-dimensional computed tomography: image formation and clinical protocol. , 2005, Medical physics.

[7]  L. Dawson,et al.  Individualized image guided iso-NTCP based liver cancer SBRT , 2006, Acta oncologica.

[8]  D. Song,et al.  Stereotactic body radiation therapy. Rationale, techniques, applications, and optimization. , 2004, Oncology.

[9]  I. Chetty,et al.  Accounting for center-of-mass target motion using convolution methods in Monte Carlo-based dose calculations of the lung. , 2004, Medical physics.

[10]  L. Dawson,et al.  The Role of Radiotherapy in the Treatment of Liver Metastases , 2004, Cancer journal.

[11]  E. Yorke,et al.  Respiratory gating for liver tumors: Use in dose escalation , 2003 .

[12]  Steve B. Jiang,et al.  Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. , 2002, Physics in medicine and biology.

[13]  H Paganetti,et al.  Effects of organ motion on IMRT treatments with segments of few monitor units. , 2007, Medical physics.

[14]  Indrin J Chetty,et al.  Dose reconstruction in deforming lung anatomy: dose grid size effects and clinical implications. , 2005, Medical physics.

[15]  M. Schell,et al.  Hypofractionated stereotactic body radiation therapy (SBRT) for limited hepatic metastases. , 2007, International journal of radiation oncology, biology, physics.

[16]  T. Pan Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT. , 2005, Medical physics.

[17]  B. Rhein,et al.  The influence of breathing motion on intensity modulated radiotherapy in the step-and-shoot technique: phantom measurements for irradiation of superficial target volumes , 2006, Physics in medicine and biology.

[18]  E. Larsen,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.

[19]  Steve B. Jiang,et al.  An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments. , 2003, Physics in medicine and biology.

[20]  Joe Y. Chang,et al.  4D Proton treatment planning strategy for mobile lung tumors. , 2007, International journal of radiation oncology, biology, physics.

[21]  Tinsu Pan,et al.  Relation of external surface to internal tumor motion studied with cine CT. , 2006, Medical physics.

[22]  Randall K Ten Haken,et al.  Alterations in normal liver doses due to organ motion. , 2003, International journal of radiation oncology, biology, physics.

[23]  Radhe Mohan,et al.  Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. , 2005, Medical physics.

[24]  Kristy K Brock,et al.  Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control. , 2005, International journal of radiation oncology, biology, physics.

[25]  R D Timmerman,et al.  How should we describe the radioblologic effect of extracranial stereotactic radlosurgery: equivalent uniform dose or tumor control probability? , 2003, Medical physics.

[26]  M. McCarter,et al.  Interim analysis of a prospective phase I/II trial of SBRT for liver metastases , 2006, Acta oncologica.

[27]  Eike Rietzel,et al.  Design of 4D treatment planning target volumes. , 2006, International journal of radiation oncology, biology, physics.

[28]  David L. Wilson,et al.  Semiautomatic nonrigid registration for the prostate and pelvic MR volumes. , 2005, Academic radiology.

[29]  D A Jaffray,et al.  The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation. , 1998, Physics in medicine and biology.

[30]  David L Wilson,et al.  A comparative study of warping and rigid body registration for the prostate and pelvic MR volumes. , 2003, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[31]  Linda Hong,et al.  The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator. , 2003, Medical physics.

[32]  Maria Hawkins,et al.  Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[33]  D L McShan,et al.  Inclusion of organ deformation in dose calculations. , 2003, Medical physics.

[34]  V. Budach,et al.  Image guided respiratory gated hypofractionated Stereotactic Body Radiation Therapy (H-SBRT) for liver and lung tumors: Initial experience , 2006, Acta oncologica.

[35]  Steve B. Jiang,et al.  Effects of motion on the total dose distribution. , 2004, Seminars in radiation oncology.

[36]  Steve B. Jiang,et al.  Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations , 2006, Physics in medicine and biology.

[37]  P Keall,et al.  Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery. , 2005, Medical physics.

[38]  Steve B. Jiang,et al.  Residual motion of lung tumors in end-of-inhale respiratory gated radiotherapy based on external surrogates. , 2006, Medical physics.

[39]  Robert D Timmerman,et al.  A phase I trial of stereotactic body radiation therapy (SBRT) for liver metastases. , 2005, International journal of radiation oncology, biology, physics.

[40]  David Jaffray,et al.  Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy. , 2006, International journal of radiation oncology, biology, physics.

[41]  J. McClelland,et al.  MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning , 2006, Physics in medicine and biology.

[42]  Robert D Timmerman,et al.  Extracranial radiosurgery (stereotactic body radiation therapy) for oligometastases. , 2006, Seminars in radiation oncology.

[43]  Joao Seco,et al.  The susceptibility of IMRT dose distributions to intrafraction organ motion: An investigation into smoothing filters derived from four dimensional computed tomography data. , 2006, Medical physics.

[44]  S. Kalnicki,et al.  Abdominal organ motion measured using 4D CT. , 2006, International journal of radiation oncology, biology, physics.

[45]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[46]  C. Meyer,et al.  Automated generation of a four-dimensional model of the liver using warping and mutual information. , 2003, Medical physics.

[47]  James M Balter,et al.  Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines. , 2004, Medical physics.

[48]  Indrin J Chetty,et al.  A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: a Monte Carlo study. , 2003, Medical physics.

[49]  J. Petersen,et al.  Internal movement, set-up accuracy and margins for stereotactic body radiotherapy using a stereotactic body frame , 2006, Acta oncologica.