Cerebral Hemoglobin and Optical Pathlength Influence Near-Infrared Spectroscopy Measurement of Cerebral Oxygen Saturation

Near-infrared spectroscopy (NIRS) is a noninvasive optical technique to monitor cerebral oxygen saturation at the bedside. Despite its applicability, NIRS has had limited clinical use because of concerns about accuracy, noted by intersubject variability in slope and intercept of the line between NIRS- and weighted-average arterial-cerebrovenous saturation (SMO2). This study evaluated transcranial optical pathlength and cerebral hemoglobin concentration as sources for this intersubject variability. Experiments were performed in an in vitro brain model and in piglets. Optical pathlength and cerebral hemoglobin concentration were measured by time-resolved spectroscopy (TRS). NIRS and TRS were recorded in the model, as perfusate blood saturation was varied (0%-100%) at several hemoglobin concentrations, and in piglets, as SMO2 was varied (15%-90%) before and after hemodilution. In the model, hemoglobin concentration significantly altered the NIRS versus blood saturation line slope and intercept, as well as optical pathlength. In piglets (before hemodilution), there was significant intersubject variability in NIRS versus SMO2 line slope (0.73-1.4) and intercept (-24 to 36) and in transcranial optical pathlength (13.4-16 cm) and cerebral hemoglobin concentration (0.58-1.1 g/dL). By adjusting the NIRS algorithm with optical pathlength or cerebral hemoglobin measurements, intersubject variability in slope (0.9-1.2) and intercept (-9 to 18) decreased significantly. Hemodilution significantly changed NIRS versus SMO2 line slope and intercept, as well as transcranial optical pathlength and cerebral hemoglobin concentration (before versus after hemodilution: slope 0.9 vs 0.78, intercept 13 vs 19, pathlength 13.9 vs 15.6 cm, cerebral hemoglobin 0.98 vs 0.73 g/dL). By adjusting the NIRS algorithm with the cerebral hemoglobin measurements, slope and intercept remained unchanged by hemodilution. These data indicate that intersubject variability in NIRS originates, in part, from biologic variations in transcranial optical pathlength and cerebral hemoglobin concentration. Instruments to account for these factors may improve NIRS cerebral oxygen saturation measurements. (Anesth Analg 1997;84:1297-305)

[1]  B. Horecker THE ABSORPTION SPECTRA OF HEMOGLOBIN AND ITS DERIVATIVES IN THE VISIBLE AND NEAR INFRA-RED REGIONS , 1943 .

[2]  J. LaManna,et al.  In situ studies of oxidative energy metabolism during transient cortical ischemia in cats , 1976, Experimental Neurology.

[3]  Susan Wray,et al.  QUANTIFICATION OF CEREBRAL OXYGENATION AND HAEMODYNAMICS IN SICK NEWBORN INFANTS BY NEAR INFRARED SPECTROPHOTOMETRY , 1986, The Lancet.

[4]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[5]  V Blazek,et al.  Optical properties of human brain tissue, meninges, and brain tumors in the spectral range of 200 to 900 nm. , 1987, Neurosurgery.

[6]  S. Arridge,et al.  Estimation of optical pathlength through tissue from direct time of flight measurement , 1988 .

[7]  S Nioka,et al.  Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain. , 1988, Proceedings of the National Academy of Sciences of the United States of America.

[8]  M. Tamura,et al.  Quantitative analysis of hemoglobin oxygenation state of rat brain in situ by near-infrared spectrophotometry. , 1988, Journal of applied physiology.

[9]  D T Delpy,et al.  Computed point spread functions for light in tissue using a measured volume scattering function. , 1988, Advances in experimental medicine and biology.

[10]  M. Reilly,et al.  Cerebral Energy Metabolism and Oxygen State during Hypoxia in Neonate and Adult Dogs , 1990, Pediatric Research.

[11]  P. W. Mccormick,et al.  Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics , 1991, Critical care medicine.

[12]  P. W. Mccormick,et al.  Regional cerebrovascular oxygen saturation measured by optical spectroscopy in humans. , 1991, Stroke.

[13]  S Nioka,et al.  Quantitation of time- and frequency-resolved optical spectra for the determination of tissue oxygenation. , 1991, Analytical biochemistry.

[14]  M. Delivoria-Papadopoulos,et al.  Fluctuations in cerebral oxygenation and blood volume during endotracheal suctioning in premature infants. , 1992, The Journal of pediatrics.

[15]  P. W. Mccormick,et al.  Cerebral oxygen metabolism during hypothermic circulatory arrest in humans. , 1993, Journal of neurosurgery.

[16]  J. Weeks,et al.  The Influence of Intravascular Volume Expansion on Cerebral Blood Flow and Blood Volume in Normal Rats , 1993, Anesthesiology.

[17]  A. Mortimer,et al.  Light‐reflective cerebral oximetry and jugular bulb venous oxygen saturation during carotid endarterectomy , 1994, The British journal of surgery.

[18]  B Chance,et al.  A dynamic phantom brain model for near-infrared spectroscopy. , 1995, Physics in medicine and biology.

[19]  Eiji Okada,et al.  Theoretical and experimental investigation of the effect of sulci on light propagation in brain tissue , 1995, European Conference on Biomedical Optics.

[20]  S. Nicolson,et al.  Cerebral Oxygenation during Pediatric Cardiac Surgery Using Deep Hypothermic Circulatory Arrest , 1995, Anesthesiology.

[21]  J D Pickard,et al.  An observational study of near-infrared spectroscopy during carotid endarterectomy. , 1995, Journal of neurosurgery.

[22]  S. Webber,et al.  Cerebral oxygenation measured by near-infrared spectroscopy: comparison with jugular bulb oximetry. , 1996, The Annals of thoracic surgery.

[23]  D. Prough,et al.  The Influence of Carbon Dioxide and Body Position on Near-Infrared Spectroscopic Assessment of Cerebral Hemoglobin Oxygen Saturation , 1996, Anesthesia and analgesia.

[24]  D. Prough,et al.  Validation in Volunteers of a Near-Infrared Spectroscope for Monitoring Brain Oxygenation In Vivo , 1996, Anesthesia and analgesia.