Continuous blood pressure monitoring during exercise using pulse wave transit time measurement

This paper gives an overview of a research, which is focused on the development of the convenient device for continuous non-invasive monitoring of arterial blood pressure. The blood pressure estimation method is based on a presumption that there is a singular relationship between the pulse wave propagation time in arterial system and blood pressure. The parameter used in this study is pulse wave transit time (PWTT). The measurement of PWTT involves the registration of two time markers, one of which is based on ECG R peak detection and another on the detection of pulse wave in peripheral arteries. The reliability of beat to beat systolic blood pressure calculation during physical exercise was the main focus for the current paper. Sixty-one subjects (healthy and hypertensive) were studied with the bicycle exercise test. As a result of current study it is shown that with the correct personal calibration it is possible to estimate the beat to beat systolic arterial blood pressure during the exercise with comparable accuracy to conventional noninvasive methods.

[1]  Hidehiro Hosaka,et al.  Comparison of the relationship between blood pressure and pulse wave transit times at different sites , 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. N.

[2]  K. Meigas,et al.  Optical and electrical methods for pulse wave transit time measurement and its correlation with arterial blood pressure , 2004, Proceedings of the Estonian Academy of Sciences. Engineering.

[3]  Kalju Meigas,et al.  Method of optical self-mixing for pulse wave transit time in comparison with other methods and correlation with blood pressure , 2004, SPIE BiOS.

[4]  T. Togawa,et al.  Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration , 2000, Medical and Biological Engineering and Computing.

[5]  N Lutter,et al.  Noninvasive continuous blood pressure control by pulse wave velocity. , 1996, Zeitschrift fur Kardiologie.

[6]  Daniel Levy,et al.  Assessment of frequency of progression to hypertension in non-hypertensive participants in the Framingham Heart Study: a cohort study , 2001, The Lancet.

[7]  Michael E Ernst,et al.  Ambulatory Blood Pressure Monitoring , 2003, Southern medical journal.

[8]  Daniel W. Jones,et al.  Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. , 2003, Hypertension.

[9]  Daniel W. Jones,et al.  The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure: the JNC 7 report. , 2003, Journal of the American Medical Association (JAMA).

[10]  D. Beevers,et al.  Clinical Hypertension , 2002, Journal of Human Hypertension.