Abstract Accurate measurements of the interfacial wave structure of upward annular two-phase flow in a vertical pipe were performed using a laser focus displacement meter (LFD). The purpose of this study was to clarify the effectiveness of the LFD for obtaining detailed information on the interfacial displacement of a liquid film in annular two-phase flow and to investigate the effect of axial distance from the air–water inlet on the phenomena. Adiabatic upward annular air–water flow experiments were conducted using a 3 m long, 11 mm ID pipe. Measurements of interfacial waves were conducted at 21 axial locations, spaced 110 mm apart in the pipe. The axial distances from the inlet (z) normalized by the pipe diameter (D) varied over z/D = 50–250. Data were collected for predetermined gas and liquid flow conditions and for Reynolds numbers ranging from ReG = 31,800 to 98,300 for the gas phase and ReL = 1050 to 9430 for the liquid phase. Using the LFD, we obtained such local properties as the minimum thickness, maximum thickness, and passing frequency of the waves. The maximum film thickness and passing frequency of disturbance waves decreased gradually, with some oscillations, as flow developed. The flow development, i.e., decreasing film thickness and passing frequency, persisted until the end of the pipe, which means that the flow might never reach the fully developed state. The minimum film thickness decreased with flow development and with increasing gas flow rate. These results are discussed, taking into account the buffer layer calculated from Karman’s three-layer model. A correlation is proposed between the minimum film thickness obtained in relation to the interfacial shear stress and the Reynolds number of the liquid.
[1]
Tatsuya Hazuku,et al.
Measuring interfacial waves on film flowing down a vertical plate wall in the entry region using laser focus displacement meters
,
2000
.
[2]
M. Kawaji,et al.
Turbulence structure under a typical shear induced wave at a liquid/gas interface
,
1996
.
[4]
G. Hewitt,et al.
Annular two-phase flow
,
1970
.
[5]
Kenji Kobayashi,et al.
Measuring interfacial waves on film flowing down tube inner wall using laser focus displacement meter
,
2000
.
[6]
G. F. Hewitt,et al.
FILM THICKNESS MEASUREMENT IN ANNULAR TWO-PHASE FLOW USING A FLUORESCENCE SPECTROMETER TECHNIQUE. PART II. STUDIES OF THE SHAPE OF DISTURBANCE WAVES.
,
1969
.
[7]
収 田中,et al.
気液環状ミスト流の流動特性 : 第2報,主要パラメータの相関式について
,
1985
.
[8]
R. M. Nedderman,et al.
The coalescence of disturbance waves in annular two phase flow
,
1968
.
[9]
A. Clegg,et al.
An experimental study of wave inception on falling liquid films
,
1972
.
[10]
T. Fukano,et al.
Fluctuation characteristics of heating surface temperature near an obstacle in transient boiling two-phase flow in a vertical annular channel
,
2003
.
[11]
T. Fukano,et al.
Relation between temperature fluctuation of a heating surface and generation of drypatch caused by a cylindrical spacer in a vertical boiling two-phase upward flow in a narrow annular channel
,
2002
.
[12]
B. J. Azzopardi.
Disturbance wave frequencies, velocities and spacing in vertical annular two-phase flow
,
1986
.