CT-based thermometry: An overview

Abstract The dependence of computed tomography (CT) values on temperature has been pointed out by several authors since the late 1970s. They emphasised the importance of this phenomenon on the calibration process with water equivalent phantoms of the CT scanners. Few years later the potential of CT thermometry for non-invasive temperature mapping during thermal procedures was investigated. The interest on the employment of this technique during thermal treatments has been recently renewed with the improvement of modern CT scanner performances and with the increased popularity of minimally invasive thermal techniques for cancer treatment. A good thermometry allows avoiding unintended damage of the healthy tissues during the procedure by providing a detailed tissue temperature distribution; therefore, it is recommended in order to achieve good effectiveness of the thermal treatment. Researchers have been working on this issue for more than four decades and different non-invasive solutions have been proposed, i.e., microwave thermal imaging, infrared (IR)-, ultrasound-, magnetic-resonance (MR)-, and CT-based thermometry. This review aims to summarise the essential physics and the currently available data on CT-based thermometry and to elucidate the potential use of this technique during thermal procedures. Background information on measuring principle, an investigation of the performances achieved by this technique and the thermal sensitivity of the CT-number of different organs are provided and discussed.

[1]  Lars Frich Non‐invasive thermometry for monitoring hepatic radiofrequency ablation , 2006, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[2]  Sergio Silvestri,et al.  Monitoring of temperature increase and tissue vaporization during laser interstitial thermotherapy of ex vivo swine liver by computed tomography , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[3]  Steffen Renisch,et al.  Image-Guided Therapy (IGT): New CT and Hybrid Imaging Technologies , 2006 .

[4]  L. Berland Practical Ct: Technology and Techniques , 1987 .

[5]  Thomas Schmitz-Rode,et al.  Multi-slice computed tomography: A tool for non-invasive temperature measurement? , 2010, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[6]  E Schena,et al.  Experimental assessment of CT-based thermometry during laser ablation of porcine pancreas , 2013, Physics in medicine and biology.

[7]  T. Flohr,et al.  Feasibility of computed tomography based thermometry during interstitial laser heating in bovine liver , 2011, European Radiology.

[8]  Liang Li,et al.  A novel metal artifact reducing method for cone-beam CT based on three approximately orthogonal projections , 2013, Physics in medicine and biology.

[9]  A H Mahnken,et al.  CT thermometry: will it ever become ready for use? , 2011, International journal of clinical practice. Supplement.

[10]  Jacob Sosna,et al.  Non-invasive temperature monitoring and hyperthermic injury onset detection using X-ray CT during HIFU thermal treatment in ex vivo fatty tissue , 2014, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[11]  Thomas Flohr,et al.  Feasibility of Noninvasive Temperature Assessment During Radiofrequency Liver Ablation on Computed Tomography , 2011, Journal of computer assisted tomography.

[12]  Rainer Raupach,et al.  A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement. , 2003, Investigative radiology.

[13]  S M Bentzen,et al.  Isotherm mapping in hyperthermia using subtraction X-ray computed tomography. , 1984, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  Sergio Silvestri,et al.  Theoretical Analysis and Experimental Evaluation of Laser-Induced Interstitial Thermotherapy in Ex Vivo Porcine Pancreas , 2012, IEEE Transactions on Biomedical Engineering.

[15]  R. R. Bowman A Probe for Measuring Temperature in Radio-Frequency-Heated Material (Short Papers) , 1976 .

[16]  M. B. Taylor,et al.  Carcinoma of unknown primary: key radiological issues from the recent National Institute for Health and Clinical Excellence guidelines. , 2012, The British journal of radiology.

[17]  S. Lipsitz,et al.  Thermal ablation vs surgery for localized kidney cancer: a Surveillance, Epidemiology, and End Results (SEER) database analysis. , 2011, Urology.

[18]  Thomas Schmitz-Rode,et al.  CT-based temperature monitoring during hepatic RF ablation: Feasibility in an animal model , 2012, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[19]  M. Cooperberg,et al.  Treatment trends for stage I renal cell carcinoma. , 2011, The Journal of urology.

[20]  Sebastien Crouzet,et al.  High intensity focused ultrasound (HIFU) for prostate cancer: Current clinical status, outcomes and future perspectives , 2010, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[21]  Ming Li,et al.  Towards cone-beam CT thermometry , 2013, Medical Imaging.

[22]  M Oudkerk,et al.  Assessment of thermal sensitivity of CT during heating of liver: an ex vivo study. , 2012, The British journal of radiology.

[23]  A Gahleitner,et al.  Temperature dependence of HU values for various water equivalent phantom materials. , 2002, Physics in medicine and biology.

[24]  N. McDannold Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: Review of validation studies , 2005, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[25]  Cynthia M. McCollough,et al.  Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT. , 2009, Medical physics.

[26]  Virginia Tsapaki,et al.  CT-guided interventional procedures without CT fluoroscopy assistance: patient effective dose and absorbed dose considerations. , 2007, AJR. American journal of roentgenology.

[27]  T. Cetas,et al.  Thermometry considerations in localized hyperthermia. , 1978, Medical physics.

[28]  Sergio Silvestri,et al.  Techniques for temperature monitoring during laser-induced thermotherapy: An overview , 2013, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[29]  P R Stauffer,et al.  Introduction: Thermal ablation therapy , 2004, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[30]  Ervin B. Podgorsak,et al.  Noninvasive thermometry with a clinical x‐ray CT scanner , 1982 .

[31]  G. Sandison,et al.  X-ray CT monitoring of iceball growth and thermal distribution during cryosurgery. , 1998, Physics in medicine and biology.

[32]  M G Mack,et al.  Laser-induced thermotherapy of malignant liver tumors: general principals, equipment(s), procedure(s)--side effects, complications and results. , 2001, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[33]  Sergio Silvestri,et al.  Laser Interstitial Thermotherapy for pancreatic tumor ablation: Theoretical model and experimental validation , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[34]  Matthew S Metcalfe,et al.  Efficacy and safety of microwave ablation for primary and secondary liver malignancies: a systematic review , 2009, European journal of gastroenterology & hepatology.

[35]  Malte L. Bahner,et al.  CT on-line monitoring of HIFU therapy , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[36]  Xiaofei Li,et al.  Is radiofrequency thermal ablation a safe and effective procedure in the treatment of pulmonary malignancies? , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[37]  M W Vannier,et al.  Fast iterative algorithm for metal artifact reduction in X-ray CT. , 2000, Academic radiology.

[38]  D E Dupuy,et al.  Image-guided radiofrequency tumor ablation: challenges and opportunities--part I. , 2001, Journal of vascular and interventional radiology : JVIR.

[39]  S. Goldberg,et al.  Temperature–density hysteresis in X-ray CT during HIFU thermal ablation: Heating and cooling phantom study , 2014, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[40]  G M Bydder,et al.  The Temperature Dependence of Computed Tomography Attenuation Values , 1979, Journal of computer assisted tomography.