Ocular microtremor: a tool for measuring depth of anaesthesia?

Ocular microtremor (OMT) is a fine high frequency tremor of the eyes caused by extra-ocular muscle activity stimulated by impulses emanating in the brain stem. Several studies have shown that the frequency of this tremor is reduced in patients whose consciousness is reduced by anaesthesia or head injury. Therefore, OMT may possibly be used to determine depth of anaesthesia. Twenty-two unpre-medicated subjects undergoing surgery with general anaesthesia were studied. OMT activity was measured at admission using the open eye piezoelectric strain gauge technique. Anaesthesia was induced with propofol using a target controlled infusion delivery system (Diprifusor™). OMT activity was then recorded at predicted plasma propofol concentrations of 1, 2, 3 and 5 µg ml−1. The patient's level of consciousness (response to command or stimulation) was assessed after each OMT measurement. OMT activity was reduced progressively at predicted plasma concentrations of propofol of 1 and 2 µg ml−1 and then plateaued between 3 and 5 µg ml−1. There was a significant difference between the last awake OMT recording and the first recording at loss of consciousness (P

[1]  C. Doré,et al.  Effect of propofol on the auditory evoked response and oesophageal contractility. , 1989, British journal of anaesthesia.

[2]  F. Ratliff,et al.  The role of physiological nystagmus in monocular acuity. , 1952, Journal of experimental psychology.

[3]  H. Sakata,et al.  Spatial properties of visual fixation neurons in posterior parietal association cortex of the monkey. , 1980, Journal of neurophysiology.

[4]  C. Bolger,et al.  Dominant frequency content of ocular microtremor from normal subjects , 1999, Vision Research.

[5]  R. Carpenter,et al.  Movements of the Eyes , 1978 .

[6]  G. Leichnetz,et al.  Cortical projections to nuclei adjacent to oculomotor complex in the medial dien‐mesencephalic tegmentum in the monkey , 1984, The Journal of comparative neurology.

[7]  I J Rampil,et al.  Anesthetic Potency (MAC) Is Independent of Forebrain Structures in the Rat , 1993, Anesthesiology.

[8]  N. Morton,et al.  Pharmacokinetic model driven infusion of propofol in children. , 1991, British journal of anaesthesia.

[9]  J G Thomas,et al.  The prognosis of the outcome of comatose states. , 1980, Resuscitation.

[10]  Hughes Cc Lipid solubility, pharmacokinetics, and the EEG: are you better off today than you were four years ago? , 1985 .

[11]  C Bolger,et al.  High frequency eye tremor: reliability of measurement. , 1992, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.