Intraoperative Transesophageal Echocardiography for Coronary Artery Assessment

Background: In surgical aortic valve replacement (SAVR), coronary arteries are routinely assessed by transesophageal echocardiography (TEE) to prevent undesirable complications. This study evaluated the capabilities and pitfalls of TEE assessment. Methods and Results: Of 147 consecutive SAVR patients undergoing aortic stenosis, the TEE records for 130 patients, in which the procedures were conducted by a single examiner, were analyzed retrospectively regarding data acquisition and the accuracy of detecting an anomalous origin, high or low takeoff, ostial diameter, and short left main truncus (LMT). The left and right coronary arteries could be visualized in every patient. A left coronary ostium >5 mm was found in 33 patients (25.4%). TEE revealed an anomalous origin in 2 patients (1.5%) that had not been diagnosed, but missed it in another patient. High takeoff was noted in 11 patients (8.3%), often associated with aortic disease necessitating aortic repair. In one such patient, occlusion of the right coronary artery was detected, necessitating coronary revascularization. Short LMT was found in 15 patients (11.8%) but misdiagnosed due to artifact in 1. During selective cardioplegia, malperfusion of the left anterior descending artery due to deep cannula placement was detected. Conclusions: TEE provides fairly accurate assessment in SAVR, including detection of undiagnosed pathologies or pitfalls related to coronary arteries, although misdiagnosis due to artifacts should be kept in mind.

[1]  A. Bhele,et al.  A Study of Course, Branches and Variations of the Coronary Arteries in the Human Cadaveric Heart , 2017 .

[2]  T. Fukutomi,et al.  Development of a new selective coronary perfusion cannula , 2013, Journal of Artificial Organs.

[3]  N. Weitzel,et al.  Intraoperative Transeophageal Echocardiography to Diagnose an Anomalous Circumflex Artery , 2013, Journal of cardiac surgery.

[4]  M. Hosapatna,et al.  Anatomical variations in the left coronary artery and its branches. , 2013, Singapore medical journal.

[5]  Susheel Kodali,et al.  Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies. , 2012, Journal of the American College of Cardiology.

[6]  S. Athavale,et al.  Origins of the Coronary Arteries and Their Significance , 2010, Clinics.

[7]  N. Kocabiyik,et al.  Anatomical Risk Factors of Coronary Heart Disease , 2010 .

[8]  H. Ozan,et al.  Koroner Kalp Hastalığının Anatomik Risk Faktörleri , 2009 .

[9]  Katsuhiko Imai,et al.  Malposition of selective cerebral perfusion catheter is not a rare event. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[10]  A. Battler,et al.  Impact of intraoperative transesophageal echocardiography in patients undergoing valve replacement. , 2004, The Annals of thoracic surgery.

[11]  A. Mazzucco,et al.  Coronary ostial enlargement to prevent stenosis after prosthetic aortic valve replacement. , 2004, The Annals of thoracic surgery.

[12]  J. Kasprzak,et al.  Coronary anomalies diagnosed with transesophageal echocardiography: complementary clinical value in adults , 1998, The International Journal of Cardiac Imaging.

[13]  Y. Niimi,et al.  The detection of coronary ostial lesions by intraoperative transesophageal echocardiography: Report of a case , 1995, Surgery Today.

[14]  M. Misfeld,et al.  Warning hint of a hidden early left main stem bifurcation during antegrade cardioplegia. , 2003, The Annals of thoracic surgery.

[15]  K. Yasuda,et al.  Thoracic and Cardiovascular Surgery in Japan during 2000 : Annual Report by The Japanese Association for Thoracic Surgery , 2002 .

[16]  J. Pepper,et al.  Coronary artery problems during homograft aortic valve replacement: role of transesophageal echocardiography. , 1997, The Annals of thoracic surgery.

[17]  T. Vicente,et al.  [Usefulness of transesophageal echocardiography in the diagnosis of coronary anomalies]. , 1996, Revista espanola de cardiologia.

[18]  M. Alam,et al.  The Role of Transesophageal Echocardiography in Identifying Anomalous Coronary Arteries , 1993, Circulation.

[19]  W. März,et al.  Left main coronary artery stenosis after aortic valve replacement: genetic disposition for accelerated arteriosclerosis after injury of the intact human coronary artery? , 1993, Coronary artery disease.

[20]  N. Nanda,et al.  Usefulness and limitations of transesophageal echocardiography in the assessment of proximal coronary artery stenosis. , 1992, Journal of the American College of Cardiology.

[21]  K. Rådegran,et al.  Damage to the right coronary artery as a cause of death after aortic valve surgery. , 1991, Scandinavian journal of thoracic and cardiovascular surgery.

[22]  J. Roelandt,et al.  Detection of left coronary artery stenosis by transoesophageal echocardiography. , 1988, European heart journal.

[23]  W. Daniel,et al.  Imaging of coronary arteries by color-coded transesophageal Doppler echocardiography. , 1988, The American journal of cardiology.

[24]  G. Sethi,et al.  Iatrogenic coronary artery stenosis following aortic valve replacement. , 1979, The Journal of thoracic and cardiovascular surgery.

[25]  E. Hazan,et al.  Postperfusion stenosis of the common left coronary artery. , 1975, The Journal of thoracic and cardiovascular surgery.