Kinetostatic Design-Refinement of Articulated Knee Braces

Knee bracing has been used to realize a variety of functional outcomes in both sport and rehabilitation application. Much of the literature focuses on the effect of knee misalignment, force reduction and superiority of custom braces over commercial over-the-counter braces. Efforts on developing exoskeletons to serve as knee augmentation systems emphasize actuation of joints, which then adds to bulkiness of ensuing designs. In lieu of this, we would like to employ a semi-active augmentation approach (by addition of springs and dampers). Such an approach serves to redirect power (motions and forces) to achieve the desired functional outcomes from the knee braces. However, the suitable selection of geometric dimensions of the brace and spring parameters to achieve desired motion- and force-profiles at the knee remains a challenge. We therefore introduce a two-stage kinetostatic design process to help customize the brace to match a desired kinematic/static performance.

[1]  Mario Lamontagne,et al.  The effect of functional knee brace design and hinge misalignment on lower limb joint mechanics. , 2008, Clinical biomechanics.

[2]  Aaron M. Dollar,et al.  Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art , 2008, IEEE Transactions on Robotics.

[3]  K. Öberg Knee mechanisms for through-knee prostheses , 1983 .

[4]  H. Kazerooni,et al.  Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX) , 2006, IEEE/ASME Transactions on Mechatronics.

[5]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 1: theoretical background. , 2005, Gait & posture.

[6]  Vijay Kumar,et al.  Kinematic and Kinetostatic Synthesis of Planar Coupled Serial Chain Mechanisms , 2002 .

[7]  Venkat Narayan Krovi,et al.  Design and virtual prototyping of user-customized assistive devices , 1998 .

[8]  Dan K Ramsey,et al.  Assessment of functional knee bracing: an in vivo three-dimensional kinematic analysis of the anterior cruciate deficient knee. , 2001, Clinical biomechanics.

[9]  Mario Lamontagne,et al.  Electromyographic and biomechanic analysis of anterior cruciate ligament deficiency and functional knee bracing. , 2003, Clinical biomechanics.

[10]  Johan Kärrholm,et al.  Simultaneous measurements of knee motion using an optical tracking system and radiostereometric analysis (RSA) , 2011, Acta orthopaedica.

[11]  Aaron M. Dollar,et al.  Design of a quasi-passive knee exoskeleton to assist running , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[12]  J. Weber,et al.  Design of an agonist-antagonist active knee prosthesis , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[13]  Robert L. Norton,et al.  Design of Machinery , 1991 .

[14]  Yoshiyuki Sankai,et al.  Development of motion instruction system with interactive robot suit HAL , 2009, 2009 IEEE International Conference on Robotics and Biomimetics (ROBIO).

[15]  J. F. Jansen,et al.  Exoskeleton for Soldier Enhancement Systems Feasibility Study , 2000 .

[16]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. , 2005, Gait & posture.

[17]  Anil K. Raj,et al.  Mina: A Sensorimotor Robotic Orthosis for Mobility Assistance , 2011, J. Robotics.

[18]  Jeffrey A. Ward,et al.  Stroke survivor gait adaptation and performance after training on a Powered Ankle Foot Orthosis , 2010, 2010 IEEE International Conference on Robotics and Automation.

[19]  Michael Goldfarb,et al.  Control and implementation of a powered lower limb orthosis to aid walking in paraplegic individuals , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[20]  A. Roy,et al.  Measurement of Human Ankle Stiffness Using the Anklebot , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[21]  Dan K Ramsey,et al.  Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo. , 2005, Gait & posture.

[22]  Constantinos Mavroidis,et al.  Active Knee Rehabilitation Orthotic Device With Variable Damping Characteristics Implemented via an Electrorheological Fluid , 2010, IEEE/ASME Transactions on Mechatronics.