Microwaving Blood as a Non‐Destructive Technique for Haemoglobin Measurements on Microlitre Samples

The non-destructive ex vivo determination of haemoglobin (Hgb) concentration offers the capability to conduct multiple red blood cell haematological measurements on a single sample, an advantage that current optical techniques are unable to offer. Here, a microwave method and device for the accurate and non-destructive determination of Hgb concentration in microlitre blood samples are described. Using broadband microwave spectroscopy, a relationship is established between the dielectric properties of murine blood and Hgb concentration that is utilized to create a technique for the determination of Hgb concentration. Subsequently, a microwave dielectric resonator-microfluidic system is implemented in the analysis of 52 murine samples with microlitre volumes and Hgb concentrations ranging from 0 to 17 g dL(-1) . Using the characterized relationship, independent and minimally invasive Hgb measurements are made on nine healthy mice as well as seven with mutations in the Adenomatous polyposis coli (APC) gene that leads to colorectal cancer and consequently anaemia.

[1]  James R. Baker-Jarvis,et al.  High-frequency dielectric measurements , 2010, IEEE Instrumentation & Measurement Magazine.

[2]  Sada Nand Dwivedi,et al.  Comparison of HemoCue method with cyanmethemoglobin method for estimation of hemoglobin. , 2002, Indian pediatrics.

[3]  P Lunkenheimer,et al.  Broadband dielectric spectroscopy on human blood. , 2011, Biochimica et biophysica acta.

[4]  R. Ruppin,et al.  Evaluation of extended Maxwell-Garnett theories , 2000 .

[5]  Lionel Lamhaut,et al.  Comparison of the Accuracy of Noninvasive Hemoglobin Monitoring by Spectrophotometry (SpHb) and HemoCue® with Automated Laboratory Hemoglobin Measurement , 2011, Anesthesiology.

[6]  Andreas Offenhäusser,et al.  Nanoliter liquid characterization by open whispering-gallery mode dielectric resonators at millimeter wave frequencies , 2008 .

[7]  B Lundberg,et al.  Evaluation of "HemoCue," a new device for determining hemoglobin. , 1986, Clinical chemistry.

[8]  R. Medzhitov,et al.  Regulation of Spontaneous Intestinal Tumorigenesis Through the Adaptor Protein MyD88 , 2007, Science.

[9]  M. Stockhausen,et al.  Concerning measurements of high complex permittivity by the resonator perturbation method , 1980 .

[10]  D. G. Archer,et al.  The Dielectric Constant of Water and Debye‐Hückel Limiting Law Slopes , 1990 .

[11]  W. Zijlstra,et al.  Determination of hemoglobin derivatives with IL 282 CO-oximeter as compared with a manual spectrophotometric five-wavelength method. , 1981, Clinical chemistry.

[12]  H. Pitot,et al.  A dominant mutation that predisposes to multiple intestinal neoplasia in the mouse. , 1990, Science.

[13]  Bertrand Debaene,et al.  Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients* , 2011, Critical care medicine.

[14]  A. Moser,et al.  ApcMin: a mouse model for intestinal and mammary tumorigenesis. , 1995, European journal of cancer.

[15]  Alexander A. Barannik,et al.  High sensitivity microwave characterization of organic molecule solutions of nanoliter volume , 2009 .

[16]  E. McLean,et al.  Worldwide prevalence of anaemia, WHO Vitamin and Mineral Nutrition Information System, 1993–2005 , 2009, Public Health Nutrition.

[17]  P Lunkenheimer,et al.  Relaxation dynamics of a protein solution investigated by dielectric spectroscopy. , 2012, Biochimica et biophysica acta.

[18]  C. Cametti,et al.  Dielectric spectroscopy of erythrocyte cell suspensions. A comparison between Looyenga and Maxwell-Wagner-Hanai effective medium theory formulations , 2002 .

[19]  S. Arnold,et al.  Single virus detection from the reactive shift of a whispering-gallery mode , 2008, Proceedings of the National Academy of Sciences.

[20]  M. Struys,et al.  Accuracy of non-invasive measurement of haemoglobin concentration by pulse co-oximetry during steady-state and dynamic conditions in liver surgery. , 2012, British journal of anaesthesia.

[21]  M. L. Le Beau,et al.  Haploinsufficiency of Apc leads to ineffective hematopoiesis. , 2010, Blood.

[22]  C. Cametti,et al.  Dielectric relaxation spectroscopy of lysozyme aqueous solutions: analysis of the δ-dispersion and the contribution of the hydration water. , 2011, The journal of physical chemistry. B.

[23]  K. T. Mathew,et al.  Diagnosis of Diabetes Mellitus using Microwaves , 2007 .

[24]  A. Lonappan Novel method of detecting cholesterol using microwaves , 2012 .

[25]  Vinu Thomas,et al.  Nondestructive Measurement of Human Blood at Microwave Frequencies , 2007 .

[26]  R. A. Waldron,et al.  Perturbation theory of resonant cavities , 1960 .

[27]  M. R. Macknet,et al.  The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution , 2010, Anesthesia and analgesia.

[28]  R. Wu,et al.  Blood glucose monitoring using microwave cavity perturbation , 2012 .