Functional and structural effects of percutaneous edge-to-edge double-orifice repair under cardiac cycle in comparison with suture repair

Percutaneous procedures for double-orifice mitral valve repair using the MitraClip® device (clip) have been recently introduced as new treatment options as alternatives to medical management and open-heart surgery, especially for patients with high estimated operative risk. Similarly to the open-heart surgical technique, where suturing is used, the clip creates a double-orifice configuration that not only improves the closing function of the valve, but also significantly modifies its behaviour, particularly in the diastolic phase. While several clinical trials have been conducted, and are ongoing, in order to assess the safety and effectiveness of this technique, a deeper knowledge of the structural and functional effects on the valve, and of the cyclic loads transmitted to the clip itself, would allow a comparison with other repair techniques, and could serve as a foundation for possible further optimization of the clip design. The effects of the MitraClip® device developed by Evalve Inc. were studied by means of a finite element model of the mitral valve, specifically developed to study the structural effects of the original, suture-based, edge-to-edge technique. A second model was developed in order to simulate the effects of a suture with similar extension from the leaflet edge in a direction to the annulus, in order to compare the two repair techniques. The mitral valve area and transvalvular pressure gradient predicted by the models for the clip and the suture are quite similar. Similar leaflet cyclic stresses, both in value and in location, were noted for the two mechanisms of linking the leaflets, while minor differences were found in the load transmitted to the suture and the clip, with slightly higher values for the clip. The model satisfactorily allowed functional parameters (valve area and transvalvular pressure gradient) and structural parameters (load, leaflet stress) to be determined. Overall, the structural effects of the clip and the suture are quite similar under the cyclic loading conditions imposed by the cardiac cycle.

[1]  D. C. Miller,et al.  Edge-to-Edge Mitral Repair: Tension on the Approximating Suture and Leaflet Deformation During Acute Ischemic Mitral Regurgitation in the Ovine Heart , 2001, Circulation.

[2]  E. Foster,et al.  Mitral valve hemodynamic effects of percutaneous edge‐to‐edge repair with the MitraClip™ device for mitral regurgitation , 2006, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[3]  Alberto Redaelli,et al.  3-D computational analysis of the stress distribution on the leaflets after edge-to-edge repair of mitral regurgitation. , 2002, The Journal of heart valve disease.

[4]  K S Kunzelman,et al.  Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: a finite element model. , 1998, The Journal of heart valve disease.

[5]  A. Yoganathan,et al.  Effects of annular size, transmitral pressure, and mitral flow rate on the edge-to-edge repair: an in vitro study. , 2006, The Annals of thoracic surgery.

[6]  L. Cohn,et al.  Surgeons' perspective on percutaneous valve repair , 2009, Coronary artery disease.

[7]  Andrea Avanzini,et al.  A computational procedure for prediction of structural effects of edge-to-edge repair on mitral valve. , 2008, Journal of biomechanical engineering.

[8]  O. Alfieri,et al.  The edge-to-edge technique: a simplified method to correct mitral insufficiency. , 1998, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[9]  G Donzella,et al.  Structural effects of an innovative surgical technique to repair heart valve defects. , 2005, Journal of biomechanics.

[10]  R Fumero,et al.  A computational study of the hemodynamics after "edge-to-edge" mitral valve repair. , 2001, Journal of biomechanical engineering.

[11]  M. Kuduvalli,et al.  Edge-to-edge technique for mitral valve repair: medium-term results with echocardiographic follow-up. , 2006, Annals of Thoracic Surgery.

[12]  E. E. van der Wall,et al.  Normal values and reproducibility of left ventricular filling parameters by radionuclide angiography , 1997, The International Journal of Cardiac Imaging.

[13]  Alberto Redaelli,et al.  An annular prosthesis for the treatment of functional mitral regurgitation: finite element model analysis of a dog bone-shaped ring prosthesis. , 2005, The Annals of thoracic surgery.

[14]  Trevor Hastie,et al.  Mitral annular size predicts Alfieri stitch tension in mitral edge-to-edge repair. , 2004, The Journal of heart valve disease.

[15]  Scott Lim,et al.  Percutaneous mitral repair with the MitraClip system: safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort. , 2009, Journal of the American College of Cardiology.

[16]  O. Alfieri,et al.  The double-orifice technique in mitral valve repair: a simple solution for complex problems. , 2001, The Journal of thoracic and cardiovascular surgery.

[17]  J. Davy,et al.  Mitral valve repair by Alfieri's technique does not limit exercise tolerance more than Carpentier's correction. , 2006, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[18]  R. Lorusso,et al.  Edge-to-edge mitral valve repair for isolated prolapse of the anterior leaflet caused by degenerative disease , 2007, Journal of cardiovascular medicine.

[19]  M. Oz,et al.  "Bow-tie" mitral valve repair: an adjuvant technique for ischemic mitral regurgitation. , 1998, The Annals of thoracic surgery.

[20]  T. Feldman,et al.  Mitral Valve Repair Using the MitraClip : From Concept to Reality , 2022 .

[21]  Ottavio Alfieri,et al.  Percutaneous valve procedures: an update. , 2008, Current problems in cardiology.

[22]  K S Kunzelman,et al.  Anatomic basis for mitral valve modelling. , 1994, The Journal of heart valve disease.