A theoretical study of quantitative flow measurements with constant infusion of short-lived isotopes.

Recent developments in the technique of constant infusion and in emission computed tomography have provided a new method for quantitative regional flow measurements. This paper re-examines critically the theoretical relationship between flow and radioactivity during constant infusion of short-lived isotopes. Sensitivity analysis is used to assess the accuracy of the method. Criteria for the selection of an appropriate half-life to meet accuracy requirements are also discussed. A method for the determination of the distribution volume of the tracer is proposed.

[1]  G L Brownell,et al.  A model for regional cerebral oxygen distribution during continuous inhalation of 15O2, C15O, and C15O2. , 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  M E Phelps,et al.  ECAT: a new computerized tomographic imaging system for positron-emitting radiopharmaceuticals. , 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  L. Mayron,et al.  Evaluation of perfusion with the 81Rb-81mKr generator. , 1976, Seminars in nuclear medicine.

[4]  R. Q. Edwards,et al.  Image Separation Radioisotope Scanning , 1963 .

[5]  F. Fazio,et al.  Assessment of regional cerebral blood flow by continuous carotid infusion of krypton-81m. , 1977, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  C J Thompson,et al.  Dynamic Positron Emission Tomography for Study of Cerebral Hemodynamics in a Cross Section of the Head Using Positron‐Emitting 68Ga‐EDTA and 77Kr , 1977, Journal of computer assisted tomography.

[7]  G T Gullberg,et al.  Quantitative potentials of dynamic emission computed tomography. , 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  J B Bassingthwaighte,et al.  Estimation of blood flow with radioactive tracers. , 1976, Seminars in nuclear medicine.

[9]  A. Harf,et al.  Regional distribution of VA/Q in man at rest and with exercise measured with krypton-81m. , 1978, Journal of applied physiology: respiratory, environmental and exercise physiology.

[10]  M. Ter-pogossian,et al.  The continuous inhalation of oxygen-15 for assessing regional oxygen extraction in the brain of man. , 1976, The British journal of radiology.

[11]  T. Jones,et al.  Continuous Assessment of Regional Myocardial Perfusion in Dogs Using Krypton‐81m , 1978, Circulation research.

[12]  F. Fazio,et al.  Assessment of regional ventilation by continuous inhalation of radioactive krypton-81m. , 1975, British medical journal.

[13]  J. K. Chan,et al.  Circular Ring Transverse Axial Positron Camera for 3-Dimensional Reconstruction of Radionuclides Distribution , 1976, IEEE Transactions on Nuclear Science.

[14]  E. Hoffman,et al.  Application of annihilation coincidence detection to transaxial reconstruction tomography. , 1975, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.