Adaptive control of phase leading compensator parameters applied to respiratory motion compensation system.

PURPOSE This study evaluates the feasibility of our previously developed Respiratory Motion Compensation System (RMCS) combined with the Phase Lead Compensator (PLC) to eliminate system delays during the compensation of respiration-induced tumor motion. The study objective is to improve the compensation effect of RMCS and the efficay of radiation therapy to reduce its side effects to the patients. MATERIAL AND METHODS In this study, LabVIEW was used to develop the proposed software for calculating real-time adaptive control parameters, combined with PLC and RMCS for the compensation of total system delay time. Experiments of respiratory motion compensation were performed using 6 pre-recorded human respiration patterns and 7 sets of different sine waves. During the experiments, a respiratory simulation device, Respiratory Motion Simulation System (RMSS), was placed on the RMCS, and the detected target motion signals by the Ultrasound Image Tracking Algorithm (UITA) were transmitted to the RMCS, and the compensation of respiration induced motion was started. Finally, the tracking error of the system is obtained by comparing the encoder signals bwtween RMSS and RMCS. The compensation efficacy is verified by the root mean squared error (RMSE) and the system compensation rate (CR). RESULTS The experimental results show that the calcuated CR with the simulated respiration patterns is between 42.85% ∼3.53% and 33.76% ∼2.62% in the Right-Left (RL) and Superior-Inferior (SI), respectively, after the RMCS compensation of using the adaptive control parameters in PLC. For the compensation results of human respiration patterns, the CR is between 58.95% ∼8.56% and 62.87% ∼9.05% in RL and SI, respectively. CONCLUSIONS During the respiratory motion compensation, the influence of the delay time of the entire system (RMCS+RMSS+UITA) on the compensation effect was improved by adding an adaptive control PLC, which reduces compensation error and helps improve efficacy of radiation therapy.

[1]  Daniel Paluszczyszyn,et al.  Couch-based motion compensation: modelling, simulation and real-time experiments , 2012, Physics in medicine and biology.

[2]  A. Rodríguez-Molinero,et al.  Normal Respiratory Rate and Peripheral Blood Oxygen Saturation in the Elderly Population , 2013, Journal of the American Geriatrics Society.

[3]  H. Chuang,et al.  Application of Ultrasound Image Tracking Algorithm for Real-Time Diaphragmatic Excursion Measurement , 2018 .

[4]  L. Ting,et al.  Tracking and compensation of respiration pattern by an automatic compensation system , 2017, Medical physics.

[5]  K. Shibuya,et al.  Evaluation of a combined respiratory-gating system comprising the TrueBeam linear accelerator and a new real-time tumor-tracking radiotherapy system: a preliminary study. , 2016, Journal of applied clinical medical physics.

[6]  G. Lockwood,et al.  Interfraction and respiratory organ motion during conformal radiotherapy in gastric cancer. , 2010, International journal of radiation oncology, biology, physics.

[7]  Warren D D'Souza,et al.  An analysis of the treatment couch and control system dynamics for respiration-induced motion compensation. , 2006, Medical physics.

[8]  Gabor Fichtinger,et al.  Monitoring tumor motion by real time 2D/3D registration during radiotherapy , 2012, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  D R McKenzie,et al.  Dynamic modeling of lung tumor motion during respiration , 2011, Physics in medicine and biology.

[10]  Suk Lee,et al.  Evaluation of mechanical accuracy for couch‐based tracking system (CBTS) , 2012, Journal of applied clinical medical physics.

[11]  Gregory C Sharp,et al.  Prediction of respiratory tumour motion for real-time image-guided radiotherapy. , 2004, Physics in medicine and biology.

[12]  K Parodi,et al.  Ion beam tracking using ultrasound motion detection. , 2014, Medical physics.

[13]  Martin F Fast,et al.  First evaluation of the feasibility of MLC tracking using ultrasound motion estimation. , 2016, Medical physics.

[14]  Kristijan Macek,et al.  Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator. , 2016, Medical physics.

[15]  Xiaozhi Zhang,et al.  4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm , 2016, Radiation Oncology.

[16]  Matthias Guckenberger,et al.  Accuracy of real-time couch tracking during 3-dimensional conformal radiation therapy, intensity modulated radiation therapy, and volumetric modulated arc therapy for prostate cancer. , 2013, International journal of radiation oncology, biology, physics.

[17]  Gregor Ochsner,et al.  Development and evaluation of a prototype tracking system using the treatment couch. , 2014, Medical physics.

[18]  F. Yin,et al.  Is diaphragm motion a good surrogate for liver tumor motion? , 2014, International journal of radiation oncology, biology, physics.

[19]  Steve B. Jiang Radiotherapy of mobile tumors. , 2006, Seminars in radiation oncology.

[20]  Ai-Ho Liao,et al.  Experimental verification of a two-dimensional respiratory motion compensation system with ultrasound tracking technique in radiation therapy. , 2018, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.