Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients

ObjectivesIn septic patients, reliable non-invasive predictors of fluid responsiveness are needed. We hypothesised that the respiratory changes in the amplitude of the plethysmographic pulse wave (ΔPPLET) would allow the prediction of changes in cardiac index following volume administration in mechanically ventilated septic patients.DesignProspective clinical investigation.SettingAn 11-bed hospital medical intensive care unit.PatientsTwenty-three deeply sedated septic patients mechanically ventilated with tidal volume ≥ 8 ml/kg and equipped with an arterial catheter and a pulse oximetry plethysmographic sensor.InterventionsRespiratory changes in pulse pressure (ΔPP), ΔPPLET and cardiac index (transthoracic Doppler echocardiography) were determined before and after volume infusion of colloids (8 ml/kg).Measurements and main resultsTwenty-eight volume challenges were performed in 23 patients. Before volume expansion, ΔPP correlated with ΔPPLET (r2 = 0.71, p < 0.001). Changes in cardiac index after volume expansion significantly (p < 0.001) correlated with baseline ΔPP (r2 = 0.76) and ΔPPLET (r2 = 0.50). The patients were defined as responders to fluid challenge when cardiac index increased by at least 15% after the fluid challenge. Such an event occurred 18 times. Before volume challenge, a ΔPP value of 12% and a ΔPPLET value of 14% allowed discrimination between responders and non-responders with sensitivity of 100% and 94% respectively and specificity of 70% and 80% respectively. Comparison of areas under the receiver operator characteristic curves showed that ΔPP and ΔPPLET predicted similarly fluid responsiveness.ConclusionThe present study found ΔPPLET to be as accurate as ΔPP for predicting fluid responsiveness in mechanically ventilated septic patients.

[1]  J. Viale,et al.  Increased intra-abdominal pressure affects respiratory variations in arterial pressure in normovolaemic and hypovolaemic mechanically ventilated healthy pigs , 2006, Intensive Care Medicine.

[2]  W. B. Murray,et al.  The peripheral pulse wave: Information overlooked , 1996, Journal of clinical monitoring.

[3]  J. Hanley,et al.  A method of comparing the areas under receiver operating characteristic curves derived from the same cases. , 1983, Radiology.

[4]  M. Levy,et al.  2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions Conference , 2003, Intensive care medicine.

[5]  Kirk H. Shelley,et al.  Arterial–Pulse Oximetry Loops: A New Method of Monitoring Vascular Tone , 1997, Journal of Clinical Monitoring.

[6]  J. Teboul,et al.  Pulse oximeter as a sensor of fluid responsiveness: do we have our finger on the best solution? , 2005, Critical care.

[7]  K. Chergui,et al.  Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients , 2004, Intensive Care Medicine.

[8]  M. Ghobashy,et al.  Analysis of the Ear Pulse Oximeter Waveform , 2006, Journal of Clinical Monitoring and Computing.

[9]  Maxime Cannesson,et al.  Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients , 2005, Critical care.

[10]  M. Ramsay,et al.  Controlled Sedation with Alphaxalone-Alphadolone , 1974, British medical journal.

[11]  Daniel A. Reuter,et al.  Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery , 2002, Intensive Care Medicine.

[12]  J. Teboul,et al.  Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. , 2001, Chest.

[13]  T. Raffin,et al.  Reliability of the thermodilution method in the determination of cardiac output in clinical practice. , 2015, The American review of respiratory disease.

[14]  Kirk H. Shelley,et al.  How Does the Plethysmogram Derived from the Pulse Oximeter Relate to Arterial Blood Pressure in Coronary Artery Bypass Graft Patients? , 2001, Anesthesia and analgesia.

[15]  R. Pizov,et al.  Pulse oximetry plethysmographic waveform during changes in blood volume. , 1999, British journal of anaesthesia.

[16]  Maxime Cannesson,et al.  Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia , 2007, European journal of anaesthesiology.

[17]  Karim Bendjelid,et al.  Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care , 2003, Intensive Care Medicine.

[18]  J. Vincent,et al.  Pulse pressure variations to predict fluid responsiveness: influence of tidal volume , 2005, Intensive Care Medicine.

[19]  J B Gross,et al.  Principles of Pulse Oximetry: Theoretical and Practical Considerations , 1989, Anesthesia and analgesia.

[20]  A. Perel,et al.  Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators. , 2005, British journal of anaesthesia.

[21]  J. Teboul,et al.  Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. , 2002, Chest.

[22]  D. Chemla,et al.  Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. , 2000, American journal of respiratory and critical care medicine.

[23]  G. Natalini,et al.  Arterial Versus Plethysmographic Dynamic Indices to Test Responsiveness for Testing Fluid Administration in Hypotensive Patients: A Clinical Trial , 2006, Anesthesia and analgesia.

[24]  Karim Bendjelid,et al.  Reply to comment on "Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care" , 2003, Intensive Care Medicine.

[25]  J. Badie,et al.  Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients , 2005, Critical care medicine.