Multi-Reception Strategy with Improved SNR for Multichannel MR Imaging
暂无分享,去创建一个
Ye Li | Xiaoliang Zhang | Chunsheng Wang | Daniel B. Vigneron | Bing Wu | D. Vigneron | Xiaoliang Zhang | Chunsheng Wang | Ye Li | B. Wu | Bing Wu
[1] S.M. Wright,et al. Using Large Arrays for SNR Improvement on Receiver Limited MRI Systems , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.
[2] Peter M. Jakob,et al. AUTO-SMASH: A self-calibrating technique for SMASH imaging , 1998, Magnetic Resonance Materials in Physics, Biology and Medicine.
[3] Peter Andersen,et al. 9.4T human MRI: Preliminary results , 2006, Magnetic resonance in medicine.
[4] P. Boesiger,et al. Electrodynamics and ultimate SNR in parallel MR imaging , 2004, Magnetic resonance in medicine.
[5] Bing Wu,et al. 7T Human Spine Imaging Arrays With Adjustable Inductive Decoupling , 2010, IEEE Transactions on Biomedical Engineering.
[6] D. Sodickson,et al. Ultimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations , 2003, Magnetic resonance in medicine.
[7] Yong Pang,et al. Parallel traveling‐wave MRI: A feasibility study , 2012, Magnetic resonance in medicine.
[8] L L Wald,et al. Phased array detectors and an automated intensity‐correction algorithm for high‐resolution MR imaging of the human brain , 1995, Magnetic resonance in medicine.
[9] L. Wald,et al. 32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry , 2006, Magnetic resonance in medicine.
[10] Shyh-Kang Jeng,et al. Quantitative spectral/spatial analysis of phased array coil in magnetic resonance imaging based on method of moment , 1999, IEEE Transactions on Medical Imaging.
[11] Xiaoliang Zhang,et al. Precompensation for mutual coupling between array elements in parallel excitation. , 2011, Quantitative imaging in medicine and surgery.
[12] Yong Pang,et al. A dual-tuned quadrature volume coil with mixed λ/2 and λ/4 microstrip resonators for multinuclear MRSI at 7 T. , 2012, Magnetic resonance imaging.
[13] Wei Chen,et al. An inverted-microstrip resonator for human head proton MR imaging at 7 tesla , 2005, IEEE Transactions on Biomedical Engineering.
[14] Daniel K Sodickson,et al. Effects of inductive coupling on parallel MR image reconstructions , 2004, Magnetic resonance in medicine.
[15] P. Boesiger,et al. Specific coil design for SENSE: A six‐element cardiac array , 2001, Magnetic resonance in medicine.
[16] W. Manning,et al. Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.
[17] Jiongjiong Wang,et al. Improved data reconstruction method for GRAPPA , 2005, Magnetic resonance in medicine.
[18] Martin Blaimer,et al. General formulation for quantitative G‐factor calculation in GRAPPA reconstructions , 2009, Magnetic resonance in medicine.
[19] Mark A. Griswold,et al. AUTO-SMASH: A self-calibrating technique for SMASH imaging , 1998 .
[20] Daniel K Sodickson,et al. Self‐calibrating parallel imaging with automatic coil sensitivity extraction , 2002, Magnetic resonance in medicine.
[21] Ravi S. Menon,et al. Transmit/receive radiofrequency coil with individually shielded elements , 2010, Magnetic resonance in medicine.
[22] N. Rofsky,et al. Shortening MR image acquisition time for volumetric interpolated breath-hold examination with a recently developed parallel imaging reconstruction technique: clinical feasibility. , 2004, Radiology.
[23] Bing Wu,et al. Multi-Channel Microstrip Transceiver Arrays Using Harmonics for High Field MR Imaging in Humans , 2012, IEEE Transactions on Medical Imaging.
[24] Renxin Chu,et al. Magnetic Resonance in Medicine 51:22–26 (2004) Signal-to-Noise Ratio and Parallel Imaging Performance of a 16-Channel Receive-Only Brain Coil Array at , 2022 .
[25] P. Roemer,et al. The NMR phased array , 1990, Magnetic resonance in medicine.
[26] K. Uğurbil,et al. Transmit and receive transmission line arrays for 7 Tesla parallel imaging , 2005, Magnetic resonance in medicine.
[27] Sharmila Majumdar,et al. Flexible transceiver array for ultrahigh field human MR imaging , 2012, Magnetic resonance in medicine.
[28] K. Uğurbil,et al. Microstrip RF surface coil design for extremely high‐field MRI and spectroscopy , 2001, Magnetic resonance in medicine.
[29] Daniel B Vigneron,et al. A practical multinuclear transceiver volume coil for in vivo MRI/MRS at 7 T. , 2012, Magnetic resonance imaging.
[30] S. Majumdar,et al. Autocalibrating parallel imaging of in vivo trabecular bone microarchitecture at 3 Tesla , 2006, Magnetic resonance in medicine.
[31] P. Boesiger,et al. SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.
[32] Robin M Heidemann,et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.
[33] D. Vigneron,et al. Numerical Analysis of Human Sample Effect on RF Penetration and Liver MR Imaging at Ultrahigh Field. , 2011, Concepts in magnetic resonance. Part B, Magnetic resonance engineering.
[34] Xiaoliang Zhang,et al. Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system. , 2011, Quantitative imaging in medicine and surgery.
[35] Xiaoliang Zhang,et al. Common-Mode Differential-Mode (CMDM) Method for Double-Nuclear MR Signal Excitation and Reception at Ultrahigh Fields , 2011, IEEE Transactions on Medical Imaging.
[36] Bing Wu,et al. Shielded Microstrip Array for 7T Human MR Imaging , 2010, IEEE Transactions on Medical Imaging.
[37] Xiaoliang Zhang,et al. Parallel Excitation in Ultrahigh Field Human MR Imaging and Multi-Channel Transmit System. , 2012, OMICS journal of radiology.
[38] C A McKenzie,et al. Coil‐by‐coil image reconstruction with SMASH , 2001, Magnetic resonance in medicine.
[39] Wei Chen,et al. Higher‐order harmonic transmission‐line RF coil design for MR applications , 2005, Magnetic resonance in medicine.
[40] A. Reykowski,et al. Mode Matrix - A Generalized Signal Combiner For Parallel Imaging Arrays , 2004 .
[41] D. Traficante. Time averaging. Does the noise really average toward zero , 1991 .
[42] A. Webb,et al. A radiofrequency coil configuration for imaging the human vertebral column at 7 T. , 2011, Journal of magnetic resonance.
[43] Lei Yuan,et al. Parallel imaging: some signal processing issues and solutions , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).
[44] Jing Yuan,et al. Tailored utilization of acquired k-space points for GRAPPA reconstruction. , 2005, Journal of magnetic resonance.
[45] K. Uğurbil,et al. A microstrip transmission line volume coil for human head MR imaging at 4T. , 2003, Journal of magnetic resonance.
[46] Mark Bydder,et al. Generalized SMASH imaging , 2002, Magnetic resonance in medicine.
[47] D. Vigneron,et al. ICE decoupling technique for RF coil array designs. , 2011, Medical physics.
[48] Scott B King,et al. Optimum SNR data compression in hardware using an Eigencoil array , 2010, Magnetic resonance in medicine.