Micro-field evoked potentials recorded from the porcine sub-dural cortical surface utilizing a microelectrode array

A sub-dural surface microelectrode array designed to detect micro-field evoked potentials has been developed. The device is comprised of an array of 350-microm square gold contacts, with bidirectional spacing of 150 microm, contained within a polyimide Kapton material. Cytotoxicity testing suggests that the device is suitable for use with animal and human patients. Implementation of the device in animal studies revealed that reliable evoked potentials could be acquired. Further work will be needed to determine how these micro-field potentials, which demonstrate selectivity for one eye, relate to the distribution of the ocular dominance columns of the occipital cortex.

[1]  Karl E. Misulis,et al.  Spehlmann's evoked potential primer : visual, auditory, and somatosensory evoked potentials in clinical diagnosis. , 1994 .

[2]  J. Magras,et al.  Retinal projections in domestic ungulates. I. The retinal projections in the sheep and the pig. , 1972, Brain research.

[3]  József Fiser,et al.  Coding of Natural Scenes in Primary Visual Cortex , 2003, Neuron.

[4]  V. Mountcastle The columnar organization of the neocortex. , 1997, Brain : a journal of neurology.

[5]  A. Georgopoulos Arm movements in monkeys: behavior and neurophysiology , 1996, Journal of Comparative Physiology A.

[6]  U. Yinon,et al.  Columnar organization of the mammalian visual cortex and its vulnerability following lesion in adult cats , 2005, Brain injury.

[7]  J. Marcilloux,et al.  Stereotaxic atlas of the pig brain , 1999, Brain Research Bulletin.

[8]  David Beversdorf,et al.  Fabrication and testing of microelectrodes for small-field cortical surface recordings , 2006, Biomedical microdevices.

[9]  F. Gekeler,et al.  Physiologische Funktionsprüfungen von Retinaimplantaten an Tiermodellen , 2001, Der Ophthalmologe.

[10]  Thomas Stieglitz,et al.  Implantable flexible electrodes for functional electrical stimulation. , 2004, Medical device technology.

[11]  D. Bozentka Biological performance of materials: fundamentals of biocompatibility , 1993 .

[12]  R. Schmidt,et al.  Cortical projection of the rat knee joint innervation and its processing in the somatosensory areas SI and SII , 2001, Experimental Brain Research.

[13]  Vernon B Mountcastle,et al.  Introduction. Computation in cortical columns. , 2003, Cerebral cortex.

[14]  P S Goldman-Rakic,et al.  Columnar organization of corticocortical projections in squirrel and rhesus monkeys: Similarity of column width in species differing in cortical volume , 1983, The Journal of comparative neurology.

[15]  H. Kawakami,et al.  Biocompatibility of fluorinated polyimide. , 2002, Journal of biomedical materials research.

[16]  T. Stieglitz,et al.  Immunohistochemical characterization of axonal sprouting and reactive tissue changes after long-term implantation of a polyimide sieve electrode to the transected adult rat sciatic nerve. , 2001, Biomaterials.