Predicting Residential Air Exchange Rates from Questionnaires and Meteorology: Model Evaluation in Central North Carolina

A critical aspect of air pollution exposure models is the estimation of the air exchange rate (AER) of individual homes, where people spend most of their time. The AER, which is the airflow into and out of a building, is a primary mechanism for entry of outdoor air pollutants and removal of indoor source emissions. The mechanistic Lawrence Berkeley Laboratory (LBL) AER model was linked to a leakage area model to predict AER from questionnaires and meteorology. The LBL model was also extended to include natural ventilation (LBLX). Using literature-reported parameter values, AER predictions from LBL and LBLX models were compared to data from 642 daily AER measurements across 31 detached homes in central North Carolina, with corresponding questionnaires and meteorological observations. Data was collected on seven consecutive days during each of four consecutive seasons. For the individual model-predicted and measured AER, the median absolute difference was 43% (0.17 h−1) and 40% (0.17 h−1) for the LBL and LBLX models, respectively. Additionally, a literature-reported empirical scale factor (SF) AER model was evaluated, which showed a median absolute difference of 50% (0.25 h−1). The capability of the LBL, LBLX, and SF models could help reduce the AER uncertainty in air pollution exposure models used to develop exposure metrics for health studies.

[1]  W. H. Engelmann,et al.  The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants , 2001, Journal of Exposure Analysis and Environmental Epidemiology.

[2]  J. Reardon,et al.  Evaluation of the Alberta air infiltration model using measurements and inter-model comparisons , 2009 .

[3]  Max H. Sherman,et al.  Relating actual and effective ventilation in determining indoor air quality , 1986 .

[4]  David E. Burmaster,et al.  Residential Air Exchange Rates in the United States: Empirical and Estimated Parametric Distributions by Season and Climatic Region , 1995 .

[5]  J. Burke,et al.  Distributions of PM2.5 source strengths for cooking from the Research Triangle Park particulate matter panel study. , 2006, Environmental science & technology.

[6]  Iain S. Walker,et al.  Field Validation of Algebraic Equations for Stack and Wind Driven Air Infiltration Calculations , 1998 .

[7]  R. Dietz,et al.  AIR INFILTRATION MEASUREMENTS IN A HOME USING A CONVENIENT PERFLUOROCARBON TRACER TECHNIQUE , 1982 .

[8]  L. Sheldon,et al.  The design and field implementation of the Detroit Exposure and Aerosol Research Study , 2009, Journal of Exposure Science and Environmental Epidemiology.

[9]  D G Shendell,et al.  Residential air exchange rates in three major US metropolitan areas: results from the Relationship Among Indoor, Outdoor, and Personal Air Study 1999-2001. , 2010, Indoor air.

[10]  M. Sherman INFILTRATION-PRESSURIZATION CORRELATION: SIMPLIFIED PHYSICAL MODELING , 1980 .

[11]  L. Wallace,et al.  Use of personal-indoor-outdoor sulfur concentrations to estimate the infiltration factor and outdoor exposure factor for individual homes and persons. , 2005, Environmental science & technology.

[12]  Michael D. Sohn,et al.  Analyzing a database of residential air leakage in the United States , 2005 .

[13]  Jonathan Thornburg,et al.  THE RESEARCH TRIANGLE PARK PARTICULATE MATTER PANEL STUDY: PM MASS CONCENTRATION RELATIONSHIPS , 2003 .

[14]  Jonathan Thornburg,et al.  The Research Triangle Park particulate matter panel study: modeling ambient source contribution to personal and residential PM mass concentrations , 2003 .

[15]  Valerie G Zartarian,et al.  The EPA's human exposure research program for assessing cumulative risk in communities , 2009, Journal of Exposure Science and Environmental Epidemiology.

[16]  R. Burnett,et al.  It's about time: A comparison of Canadian and American time–activity patterns† , 2002, Journal of Exposure Analysis and Environmental Epidemiology.

[17]  L. Wallace,et al.  Continuous measurements of air change rates in an occupied house for 1 year: The effect of temperature, wind, fans, and windows* , 2002, Journal of Exposure Analysis and Environmental Epidemiology.