Exploration of combustion limitations and alternatives to the NBS (Bational Bureau of Standards) toxicity test method
暂无分享,去创建一个
Some limitations and potential limitations of the NBS toxicity screening test method had been identified in earlier work. These limitations have now been explored in greater detail. Also investigated was an alternative combustion system, consisting of a radiant cone heater, identical to the one in the recently developed Cone Calorimeter, an enclosed combustion chamber, and a slightly revised variant of the animal chamber. The new animal chamber was so constructed that, prior to the insertion of the animals, it could be evacuated and then back-filled with a desired sampling of the combustion products. The radiant combustion system showed a different mix of capabilities and limitations compared to the cup furnace combustor in the existing test method. In the present project, the more detailed assessment of the cup furnace operation leads to the recommendation that there is no single, universally preferable combustion environment, but that the cup furnace is adequate for the intended purpose of providing toxicity screening.