Susceptibility of Legionella pneumophila to chlorine in tap water

A study was conducted to compare the susceptibility of legionellae and coliforms to disinfection by chlorine. The chlorine residuals used were similar to concentrations that might be found in the distribution systems of large public potable water supplies. The effects of various chlorine concentrations, temperatures, and pH levels were considered. A number of different Legionella strains, both environmental and clinical, were tested. The results indicate that legionellae are much more resistant to chlorine than are coliform bacteria. At 21 degrees C, pH 7.6, and 0.1 mg of free chlorine residual per liter, a 99% kill of L. pneumophila was achieved within 40 min, compared with less than 1 min for Escherichia coli. The observed resistance is enhanced as conditions for disinfection become less optimal. The required contact time for the removal of L. pneumophilia was twice as long at 4 degrees C than it was at 21 degrees C. These data suggest that legionellae can survive low levels of chlorine for relatively long periods of time.

[1]  T. A. Thompson,et al.  Laboratory studies of disinfectants against Legionella pneumophila , 1980, Applied and environmental microbiology.

[2]  R M Wadowsky,et al.  Multiplication of Legionella pneumophila in unsterilized tap water , 1982, Applied and environmental microbiology.

[3]  G. Hodges,et al.  Susceptibility of Legionella pneumophila to three cooling tower microbicides , 1981, Applied and environmental microbiology.

[4]  R. Wadowsky,et al.  Glycine-containing selective medium for isolation of Legionellaceae from environmental specimens , 1981, Applied and environmental microbiology.

[5]  J. Dowling,et al.  Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures , 1982, Applied and environmental microbiology.

[6]  J. Wells,et al.  Isolation of Legionella spp. from environmental water samples by low-pH treatment and use of a selective medium , 1981, Journal of clinical microbiology.

[7]  P. Kabler,et al.  Resistance of Various Strains of E. Typhi and Coli aerogenes to Chlorine and Chloramine , 1936 .

[8]  Harold Farmer,et al.  STANDARD METHODS OF WATER ANALYSIS. , 1928, Science.

[9]  R. Woodward,et al.  The inactivation of spores of Bacillus globigii and Bacillus anthracis by free available chlorine. , 1958, Applied microbiology.

[10]  Alfred P. Dufour,et al.  Drinking water and Legionnaires' Disease , 1982 .

[11]  J. C. Hoff,et al.  Inactivation of Giardia Cysts by Chlorine , 1982, Applied and environmental microbiology.

[12]  E. Jarroll,et al.  Effect of Chlorine on Giardia lamblia Cyst Viability , 1981, Applied and environmental microbiology.

[13]  J. A. Taylor,et al.  LEGIONELLA PNEUMOPHILA IN WATER PLUMBING SYSTEMS , 1982, The Lancet.

[14]  F. W. Gilcreas,et al.  Standard methods for the examination of water and waste water. , 1966, American journal of public health and the nation's health.

[15]  D. Ellis The Joint Commission on Accreditation of Hospitals. , 1982, American College of Physicians observer.

[16]  M. Blaser,et al.  Growth, survival, and resistance of the Legionnaires' disease bacterium. , 1979, Annals of internal medicine.

[17]  D. Mackel,et al.  Failure of Legionella pneumophila sensitivities to predict culture results from disinfectant-treated air-conditioning cooling towers , 1982, Applied and environmental microbiology.

[18]  R. Weaver,et al.  Detection of Legionnaires disease bacteria by direct immunofluorescent staining , 1978, Journal of clinical microbiology.

[19]  R. J. Gibson,et al.  Pittsburgh pneumonia agent: direct isolation from human lung tissue. , 1980, The Journal of infectious diseases.

[20]  M. Muers,et al.  LEGIONNAIRES' DISEASE IN A TRANSPLANT UNIT: ISOLATION OF THE CAUSATIVE AGENT FROM SHOWER BATHS , 1980, The Lancet.

[21]  L. Burley The Chlorination of Water , 1921, The Hospital and health review.

[22]  A. Nelson,et al.  INVESTIGATION AND CONTROL OF AN OUTBREAK OF LEGIONNAIRES' DISEASE IN A DISTRICT GENERAL HOSPITAL , 1981, The Lancet.

[23]  V. Yu,et al.  Ubiquitousness of Legionella pneumophila in the water supply of a hospital with endemic Legionnaires' disease. , 1982, The New England journal of medicine.

[24]  A. W. Fynsk,et al.  Treatment of cooling systems containing high levels of Legionella pneumophila , 1982 .

[25]  R. Fallon,et al.  Legionnaires' disease: further evidence to implicate water storage and distribution systems as sources. , 1981, British medical journal.

[26]  C. Fliermans,et al.  Isolation of Legionella pneumophila from nonepidemic-related aquatic habitats. , 1979, Applied and environmental microbiology.