Performance Analyses of Counter-Flow Closed Wet Cooling Towers Based on a Simplified Calculation Method

As one of the most widely used units in water cooling systems, the closed wet cooling towers (CWCTs) have two typical counter-flow constructions, in which the spray water flows from the top to the bottom, and the moist air and cooling water flow in the opposite direction vertically (parallel) or horizontally (cross), respectively. This study aims to present a simplified calculation method for conveniently and accurately analyzing the thermal performance of the two types of counter-flow CWCTs, viz. the parallel counter-flow CWCT (PCFCWCT) and the cross counter-flow CWCT (CCFCWCT). A simplified cooling capacity model that just includes two characteristic parameters is developed. The Levenberg–Marquardt method is employed to determine the model parameters by curve fitting of experimental data. Based on the proposed model, the predicted outlet temperatures of the process water are compared with the measurements of a PCFCWCT and a CCFCWCT, respectively, reported in the literature. The results indicate that the predicted values agree well with the experimental data in previous studies. The maximum absolute errors in predicting the process water outlet temperatures are 0.20 and 0.24 °C for the PCFCWCT and CCFCWCT, respectively. These results indicate that the simplified method is reliable for performance prediction of counter-flow CWCTs. Although the flow patterns of the two towers are different, the variation trends of thermal performance are similar to each other under various operating conditions. The inlet air wet-bulb temperature, inlet cooling water temperature, air flow rate, and cooling water flow rate are crucial for determining the cooling capacity of a counter-flow CWCT, while the cooling tower effectiveness is mainly determined by the flow rates of air and cooling water. Compared with the CCFCWCT, the PCFCWCT is much more applicable in a large-scale cooling water system, and the superiority would be amplified when the scale of water distribution system increases. Without multiple iterative calculations and extensive experimental data, the simplified method could be used to effectively analyze the thermal performance of counter-flow CWCTs in operation. It is useful for optimization operation of counter-flow CWCTs such that to improve the energy efficiency of the overall cooling water system.

[1]  Ebrahim Hajidavalloo,et al.  Thermal performance of cross flow cooling towers in variable wet bulb temperature , 2010 .

[2]  Arturo Jiménez-Gutiérrez,et al.  MINLP optimization of mechanical draft counter flow wet-cooling towers , 2010 .

[3]  Yu Wang,et al.  Artificial neural network analysis of the performance characteristics of a reversibly used cooling tower under cross flow conditions for heat pump heating system in winter , 2011 .

[4]  J. Bertin Engineering fluid mechanics , 1984 .

[5]  Ala Hasan,et al.  Theoretical and computational analysis of closed wet cooling towers and its applications in cooling of buildings , 2002 .

[6]  Ho-Saeng Lee,et al.  Enhancement of cooling capacity in a hybrid closed circuit cooling tower , 2009 .

[7]  Lihua Xie,et al.  HVAC system optimization––condenser water loop , 2004 .

[8]  Saffa Riffat,et al.  Application of CFD to closed-wet cooling towers , 2001 .

[9]  Ricardo de Araújo Kalid,et al.  Efficiency control in a commercial counter flow wet cooling tower , 2009 .

[10]  Armando C. Oliveira,et al.  Thermal behaviour of closed wet cooling towers for use with chilled ceilings , 2000 .

[11]  Yi Jiang,et al.  Experimental and numerical analysis of a cross-flow closed wet cooling tower , 2013 .

[12]  Saffa Riffat,et al.  Numerical simulation of closed wet cooling towers for chilled ceiling systems , 1999 .

[13]  Dominique Marchio,et al.  Simplified model for indirect-contact evaporative cooling-tower behaviour , 2004 .

[15]  Ruzhu Wang,et al.  Study on a silica gel–water adsorption chiller integrated with a closed wet cooling tower , 2010 .

[16]  Donal Finn,et al.  Heat transfer correlations for low approach evaporative cooling systems in buildings , 2009 .

[17]  A. K. M. Mohiuddin,et al.  Knowledge base for the systematic design of wet cooling towers. Part I: Selection and tower characteristics , 1996 .

[18]  Syed M. Zubair,et al.  Performance characteristics of counter flow wet cooling towers , 2003 .

[20]  M.M.A. Sarker,et al.  Performance characteristics of the hybrid closed circuit cooling tower , 2008 .

[21]  Antonio Viedma,et al.  Experimental study on the thermal performance of a mechanical cooling tower with different drift eliminators , 2009 .

[22]  Ruzhu Wang,et al.  Numerical simulation of a closed wet cooling tower with novel design , 2011 .

[23]  Shyan-Shu Shieh,et al.  Discrete model-based operation of cooling tower based on statistical analysis , 2013 .

[24]  S. Yoo,et al.  Thermal performance analysis of heat exchanger for closed wet cooling tower using heat and mass transfer analogy , 2010 .

[25]  Tullie Circle,et al.  AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING , 2013 .

[26]  Suoying He,et al.  Comparative study on the performance of natural draft dry, pre-cooled and wet cooling towers , 2016 .

[27]  Wei-Ye Zheng,et al.  Experimental and computational analysis of thermal performance of the oval tube closed wet cooling tower , 2012 .

[28]  Fengzhong Sun,et al.  Performance prediction of wet cooling tower using artificial neural network under cross-wind conditions , 2009 .

[29]  Richard Karl Strand,et al.  Modeling of simultaneous heat and mass transfer within passive down-draft evaporative cooling (PDEC) towers with spray in FLUENT , 2013 .

[30]  Shanshan Yu,et al.  Performance prediction of a shower cooling tower using wavelet neural network , 2016 .

[31]  E. D. Rogdakis,et al.  Thermodynamic study of the effects of ambient air conditions on the thermal performance characteristics of a closed wet cooling tower , 2012 .

[32]  Wenjian Cai,et al.  A simplified modeling of mechanical cooling tower for control and optimization of HVAC systems , 2007 .

[33]  Ala Hasan,et al.  Simplification of analytical models and incorporation with CFD for the performance predication of closed‐wet cooling towers , 2002 .

[34]  Yang Hongxing,et al.  An analytical model for the heat and mass transfer processes in indirect evaporative cooling with parallel/counter flow configurations , 2006 .