Sampling Efficiency and Performance of Selected Thoracic Aerosol Samplers

Measurement of worker exposure to a thoracic health-related aerosol fraction is necessary in a number of occupational situations. This is the case of workplaces with atmospheres polluted by fibrous particles, such as cotton dust or asbestos, and by particles inducing irritation or bronchoconstriction such as acid mists or flour dust. Three personal and two static thoracic aerosol samplers were tested under laboratory conditions. Sampling efficiency with respect to particle aerodynamic diameter was measured in a horizontal low wind tunnel and in a vertical calm air chamber. Sampling performance was evaluated against conventional thoracic penetration. Three of the tested samplers performed well, when sampling the thoracic aerosol at nominal flow rate and two others performed well at optimized flow rate. The limit of flow rate optimization was found when using cyclone samplers.

[1]  M. Harper,et al.  Calibration of high flow rate thoracic-size selective samplers , 2016, Journal of occupational and environmental hygiene.

[2]  M. Harper,et al.  Collection Efficiencies of High Flow Rate Personal Respirable Samplers When Measuring Arizona Road Dust and Analysis of Quartz by X-ray Diffraction , 2014, The Annals of occupational hygiene.

[3]  D. Breuer,et al.  Sulfuric acid at workplaces--applicability of the new Indicative Occupational Exposure Limit Value (IOELV) to thoracic particles. , 2012, Journal of environmental monitoring : JEM.

[4]  J. Siemiatycki,et al.  A Population-Based Case-Control Study of Occupational Exposure to Acids and the Risk of Lung Cancer: Evidence for Specificity of Association , 2011, International journal of occupational and environmental health.

[5]  Martin Harper,et al.  Performance of High Flow Rate Samplers for Respirable Particle Collection , 2010, The Annals of occupational hygiene.

[6]  Xavier Simon,et al.  Laboratory study of selected personal inhalable aerosol samplers. , 2010, The Annals of occupational hygiene.

[7]  S. Trakumas,et al.  Parallel particle impactor ? novel size-selective particle sampler for accurate fractioning of inhalable particles , 2009 .

[8]  Olivier Witschger,et al.  Aerosol sampling by annular aspiration slots. , 2008, Journal of environmental monitoring : JEM.

[9]  J. Fabries,et al.  Physical and biochemical properties of airborne flour particles involved in occupational asthma. , 2008, The Annals of occupational hygiene.

[10]  E Kauffer,et al.  Thoracic size-selective sampling of fibres: performance of four types of thoracic sampler in laboratory tests. , 2005, The Annals of occupational hygiene.

[11]  A. Maynard Thoracic size-selection of fibres: dependence of penetration on fibre length for five thoracic sampler types. , 2002, The Annals of occupational hygiene.

[12]  L. Kenny Aerosol sampler testing exchange (ASTEX) , 2000 .

[13]  Göran Lidén,et al.  Presentation of the results from round 1 of ASTEX , 2000 .

[14]  Richard Wrobel,et al.  Experimental method to determine the efficiency of aerosolsamplers using the Coulter counter , 2000 .

[15]  Andrew D. Maynard,et al.  Measurement of aerosol penetration through six personal thoracic samplers under calm air conditions , 1999 .

[16]  P. Brochard,et al.  The use of a new static device based on the collection of the thoracic fraction for the assessment of the airborne concentration of asbestos fibres by transmission electron microscopy. , 1996, The Annals of occupational hygiene.

[17]  L. C. Kenny,et al.  Characterization and modelling of a family of cyclone aerosol preseparators , 1995 .

[18]  K. Willeke,et al.  A general equation for aerosol aspiration by thin-walled sampling probes in calm and moving air , 1993 .

[19]  L. C. Kenny,et al.  THE PERFORMANCE OF RESPIRABLE DUST SAMPLERS: SAMPLER BIAS, PRECISION AND INACCURACY , 1992 .

[20]  G. Lidén,et al.  Comparison of measured respirable dust sampler penetration curves with sampling conventions. , 1991, The Annals of occupational hygiene.

[21]  J. Dement Overview: Workshop on Fiber Toxicology Research Needs , 1990 .

[22]  N. P. Vaughan,et al.  Construction and testing of an axial flow cyclone preseparator , 1988 .

[23]  M. Lippmann,et al.  Basis for a particle size-selective TLV for sulfuric acid aerosols , 1987 .

[24]  L L Kupper,et al.  Laryngeal cancer and occupational exposure to sulfuric acid. , 1984, American journal of epidemiology.

[25]  P. Görner,et al.  Study of fifteen respirable aerosol samplers used in occupational hygiene. , 2001, The Annals of occupational hygiene.

[26]  P. Görner,et al.  Personal thoracic CIP10-T sampler and its static version CATHIA-T. , 1998, The Annals of occupational hygiene.

[27]  A. Maynard,et al.  A survey of wind speeds in indoor workplaces. , 1998, The Annals of occupational hygiene.

[28]  K. Willeke,et al.  Overall efficiency of tubular inlets sampling at 0-90 degrees from horizontal aerosol flows , 1990 .

[29]  S C Soderholm,et al.  Proposed international conventions for particle size-selective sampling. , 1989, The Annals of occupational hygiene.

[30]  N. Vaughan,et al.  A higher-flow rate cyclone for determination of respirable dust. , 1987, The Annals of occupational hygiene.

[31]  M. Corn Methods to assess airborne concentrations of cotton dust. , 1987, American journal of industrial medicine.

[32]  J. Fabries,et al.  Equipment for the study of air sampling instruments with real time measurement of the aerosol concentration , 1984 .

[33]  J H Vincent,et al.  On the quantitative definition of the inhalability of airborne dust. , 1981, The Annals of occupational hygiene.

[34]  J. F. Fabries,et al.  Realization of a Dust Tunnel - Response of Some Air Sampling Instruments Used in Industrial Hygiene , 1980 .

[35]  J. Guichard AEROSOL GENERATION USING FLUIDIZED BEDS , 1976 .

[36]  A. Shah,et al.  Sulfuric acid , 1924 .