Comparison of radially-symmetric versus oriented channel. Models using channelized hotelling observers for myocardial defect detection in parallel-hole SPECT

The objective of this study was to compare defect detection performance found using radially-symmetric (RS) and radially-symmetric broken into oriented channels (OC) models in channelized Hotelling observers with that from a previously reported human observer ROC study. The main goal of the human observer study was to compare detection performance of left-ventricular myocardial perfusion defects using filtered-backprojection (FB) image reconstruction without attenuation compensation to defect detection performance using maximum-likelihood expectation-maximization (ML-EM) image reconstruction with nonuniform attenuation compensation (AC). This was performed for cases of no significant attenuation artifacts (male anatomy, flat diaphragm MF) and significant attenuation reconstruction artifacts (male with raised diaphragm, MR; female with large breasts, F). The areas under the ROC curves (A/sub x/) for the Hotelling observers with both channel models (RS, OC) were calculated and compared to those found in the human observer study. Similar trends with the RC channel model were seen in average observer performance for both human and channelized Hotelling observers in both FB without AC and ML-EM with AC over the three different anatomy types except for the MF anatomy reconstructed with FB. The correlation coefficient for the 6 average observer performances was 0.84. Improved agreement between the human and channelized Hotelling observers was found when using the OC channel model. The correlation coefficient found was 0.94, again with the MF anatomy reconstructed with FB as the most significant difference between the human and channelized Hotelling observer results. Further investigation of the channel models is needed to determine number and alignment of orientations and number and cutoff of frequency bands to improve agreement between human and Hotelling observer results.

[1]  Evaluation of the effect of reconstructed image pixel size on defect detectability in Tl-201 fan-beam SPECT by an observer performance study , 1994, Proceedings of 1994 IEEE Nuclear Science Symposium - NSS'94.

[2]  H H Barrett,et al.  Hotelling trace criterion and its correlation with human-observer performance. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[3]  Jannick P. Rolland,et al.  Factors influencing lesion detection in medical imaging. , 1990 .

[4]  Craig K. Abbey,et al.  Practical issues and methodology in assessment of image quality using model observers , 1997, Medical Imaging.

[5]  Kyle Jean Myers,et al.  Visual perception in correlated noise , 1985 .

[6]  Kyle J. Myers,et al.  Model observers for assessment of image quality , 1993 .

[7]  Michael A. King,et al.  Comparison of the channelized Hotelling and human observers for lesion detection in hepatic SPECT imaging , 1997, Medical Imaging.

[8]  A E Burgess,et al.  Visual signal detectability with two noise components: anomalous masking effects. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[9]  H. Barrett,et al.  Effect of noise correlation on detectability of disk signals in medical imaging. , 1985, Journal of the Optical Society of America. A, Optics and image science.

[10]  H H Barrett,et al.  Objective assessment of image quality: effects of quantum noise and object variability. , 1990, Journal of the Optical Society of America. A, Optics and image science.

[11]  Harrison H. Barrett,et al.  Hotelling trace criterion as a figure of merit for the optimization of imaging systems , 1986 .

[12]  Eric C. Frey,et al.  Evaluation of myocardial defect detection between parallel-hole and fan-beam SPECT using the Hotelling trace , 1997 .

[13]  C. Metz ROC Methodology in Radiologic Imaging , 1986, Investigative radiology.

[14]  H H Barrett,et al.  Addition of a channel mechanism to the ideal-observer model. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[15]  Eric C. Frey,et al.  Evaluation of myocardial defect detection between parallel-hole and fan-beam SPECT using the Hotelling trace , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[16]  Robin N. Strickland,et al.  Channelized detection filters for detecting tumors in nuclear medical images , 1997, Medical Imaging.

[17]  Matt A. King,et al.  Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.