Continuous PPG-Based Blood Pressure Monitoring Using Multi-Linear Regression

In this work, we present the Senbiosys blood pressure monitoring algorithm (SB-BPM) that solely requires a photoplethysmography (PPG) signal. The technology is based on pulse wave analysis (PWA) of PPG signals retrieved from different body locations to continuously estimate the systolic blood pressure (SBP) and the diastolic blood pressure (DBP).

[1]  Matthias Görges,et al.  University of Queensland Vital Signs Dataset: Development of an Accessible Repository of Anesthesia Patient Monitoring Data for Research , 2012, Anesthesia and analgesia.

[2]  Yue Zhang,et al.  A SVM Method for Continuous Blood Pressure Estimation from a PPG Signal , 2017, ICMLC.

[3]  Christophe Verjus,et al.  PPG-Based Blood Pressure Monitoring by Pulse Wave Analysis: Calibration Parameters are Stable for Three Months , 2019, 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[4]  Matthew R. Weir,et al.  In the clinic: hypertension. , 2014, Annals of internal medicine.

[5]  J. Sztajzel Heart rate variability: a noninvasive electrocardiographic method to measure the autonomic nervous system. , 2004, Swiss medical weekly.

[6]  S. Haddad,et al.  Beat-to-Beat Detection Accuracy Using the Ultra Low Power Senbiosys PPG Sensor , 2020 .

[7]  Haruki Kawanaka,et al.  Features Extraction for Cuffless Blood Pressure Estimation by Autoencoder from Photoplethysmography , 2018, 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[8]  U. Rajendra Acharya,et al.  Heart rate variability: a review , 2006, Medical and Biological Engineering and Computing.

[9]  Survi Kyal,et al.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice , 2015, IEEE Transactions on Biomedical Engineering.

[10]  Haruki Kawanaka,et al.  Cuffless Blood Pressure Estimation from only the Waveform of Photoplethysmography using CNN , 2019, 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[11]  Younho Kim,et al.  Cuff-Less Blood Pressure Estimation Using Pulse Waveform Analysis and Pulse Arrival Time , 2018, IEEE Journal of Biomedical and Health Informatics.

[12]  Derek Abbott,et al.  How Effective Is Pulse Arrival Time for Evaluating Blood Pressure? Challenges and Recommendations from a Study Using the MIMIC Database , 2019, Journal of clinical medicine.

[13]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[14]  Mingshan Sun,et al.  Optical blood pressure estimation with photoplethysmography and FFT-based neural networks. , 2016, Biomedical optics express.

[15]  M K Park,et al.  Comparison of auscultatory and oscillometric blood pressures. , 2001, Archives of pediatrics & adolescent medicine.

[16]  Qiao Zhang,et al.  Noninvasive cuffless blood pressure estimation using pulse transit time and Hilbert-Huang transform , 2013, Comput. Electr. Eng..

[17]  Federico S. Cattivelli,et al.  Noninvasive Cuffless Estimation of Blood Pressure from Pulse Arrival Time and Heart Rate with Adaptive Calibration , 2009, 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks.

[18]  Guillaume Bonnier,et al.  Machine Learning Approaches For Improved Continuous, Non-occlusive Arterial Pressure Monitoring Using Photoplethysmography , 2020, 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC).

[19]  Antti Vehkaoja,et al.  Performance of Wrist Photoplethysmography in Monitoring Atrial Fibrillation in Post Cardiac Surgery Patients , 2019, 2019 Computing in Cardiology (CinC).

[20]  A. Yli-Hankala,et al.  Ectopic Beat Detection from Wrist Optical Signals for Sinus Rhythm and Atrial Fibrillation Subjects , 2019, IFMBE Proceedings.

[21]  Mitja Lustrek,et al.  Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network , 2019, Sensors.

[22]  Zhi-Hong Mao,et al.  Cuff-free blood pressure estimation using pulse transit time and heart rate , 2014, 2014 12th International Conference on Signal Processing (ICSP).

[23]  Domenico Grimaldi,et al.  A Neural Network-based method for continuous blood pressure estimation from a PPG signal , 2013, 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[24]  Haruki Kawanaka,et al.  Cuffless Blood Pressure Estimation Based on Data-Oriented Continuous Health Monitoring System , 2017, Comput. Math. Methods Medicine.

[25]  Y.T. Zhang,et al.  Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[26]  J. Stradling,et al.  Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep , 1994, BMJ.

[27]  Aniruddha Sinha,et al.  Estimating blood pressure using Windkessel model on photoplethysmogram , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[28]  Adrian Tarniceriu,et al.  Optical wrist-worn device for sleep monitoring , 2017 .

[29]  J. Thayer,et al.  eview meta-analysis of heart rate variability and neuroimaging studies : Implications or heart rate variability as a marker of stress and health , 2012 .

[30]  O. Chételat,et al.  Parametric estimation of pulse arrival time: a robust approach to pulse wave velocity , 2009, Physiological measurement.