Validation of 3D EM Reconstructions: The Phantom in the Noise

Validation is a necessity to trust the structures solved by electron microscopy by single particle techniques. The impressive achievements in single particle reconstruction fuel its expansion beyond a small community of image processing experts. This poses the risk of inappropriate data processing with dubious results. Nowhere is it more clearly illustrated than in the recovery of a reference density map from pure noise aligned to that map—a phantom in the noise. Appropriate use of existing validating methods such as resolution-limited alignment and the processing of independent data sets (“gold standard”) avoid this pitfall. However, these methods can be undermined by biases introduced in various subtle ways. How can we test that a map is a coherent structure present in the images selected from the micrographs? In stead of viewing the phantom emerging from noise as a cautionary tale, it should be used as a defining baseline. Any map is always recoverable from noise images, provided a sufficient number of images are aligned and used in reconstruction. However, with smaller numbers of images, the expected coherence in the real particle images should yield better reconstructions than equivalent numbers of noise or background images, even without masking or imposing resolution limits as potential biases. The validation test proposed is therefore a simple alignment of a limited number of micrograph and noise images against the final reconstruction as reference, demonstrating that the micrograph images yield a better reconstruction. I examine synthetic cases to relate the resolution of a reconstruction to the alignment error as a function of the signal-to-noise ratio. I also administered the test to real cases of publicly available data. Adopting such a test can aid the microscopist in assessing the usefulness of the micrographs taken before committing to lengthy processing with questionable outcomes.

[1]  M Vanheel,et al.  DETECTION OF OBJECTS IN QUANTUM-NOISE-LIMITED IMAGES , 1982 .

[2]  Alexander McPherson,et al.  High-resolution structure of proteinase K cocrystallized with digalacturonic acid. , 2009, Acta crystallographica. Section F, Structural biology and crystallization communications.

[3]  Michael S. Spilman,et al.  ResLog plots as an empirical metric of the quality of cryo-EM reconstructions. , 2014, Journal of structural biology.

[4]  A. Brünger Free R value: a novel statistical quantity for assessing the accuracy of crystal structures , 1992, Nature.

[5]  S Jonić,et al.  Spectral signal-to-noise ratio and resolution assessment of 3D reconstructions. , 2005, Journal of structural biology.

[6]  Markus Fischer,et al.  A structure-based model of the reaction catalyzed by lumazine synthase from Aquifex aeolicus. , 2003, Journal of molecular biology.

[7]  Gunnar F. Schröder,et al.  Cross-validation in cryo-EM–based structural modeling , 2013, Proceedings of the National Academy of Sciences.

[8]  Xiaodong Yan,et al.  Three-dimensional reconstruction of icosahedral particles from single micrographs in real time at the microscope. , 2013, Journal of structural biology.

[9]  Sriram Subramaniam,et al.  Structure of trimeric HIV-1 envelope glycoproteins , 2013, Proceedings of the National Academy of Sciences.

[10]  R. Henderson,et al.  High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy☆ , 2013, Ultramicroscopy.

[11]  T. Baker,et al.  A model-based approach for determining orientations of biological macromolecules imaged by cryoelectron microscopy. , 1996, Journal of structural biology.

[12]  Pawel A Penczek,et al.  Estimating alignment errors in sets of 2-D images. , 2005, Journal of structural biology.

[13]  W. Kühlbrandt The Resolution Revolution , 2014, Science.

[14]  Gabriel C Lander,et al.  A test-bed for optimizing high-resolution single particle reconstructions. , 2008, Journal of structural biology.

[15]  T S Baker,et al.  A method for establishing the handedness of biological macromolecules. , 1997, Journal of structural biology.

[16]  Christos Gatsogiannis,et al.  Keyhole limpet hemocyanin: 9-A CryoEM structure and molecular model of the KLH1 didecamer reveal the interfaces and intricate topology of the 160 functional units. , 2009, Journal of molecular biology.

[17]  Joachim Frank,et al.  Exploration of parameters in cryo-EM leading to an improved density map of the E. coli ribosome. , 2008, Journal of structural biology.

[18]  W. Chiu,et al.  Averaging tens to hundreds of icosahedral particle images to resolve protein secondary structure elements using a Multi-Path Simulated Annealing optimization algorithm. , 2007, Journal of structural biology.

[19]  Richard Henderson,et al.  Tilt-Pair Analysis of Images from a Range of Different Specimens in Single-Particle Electron Cryomicroscopy , 2011, Journal of molecular biology.

[20]  Laurent Joyeux,et al.  Efficiency of 2D alignment methods. , 2002, Ultramicroscopy.

[21]  J. Frank,et al.  Determination of signal-to-noise ratios and spectral SNRs in cryo-EM low-dose imaging of molecules. , 2009, Journal of structural biology.

[22]  David Baker,et al.  Cryo‐EM model validation using independent map reconstructions , 2013, Protein science : a publication of the Protein Society.

[23]  M. Borgnia,et al.  Visualization of alpha-helical features in a density map constructed using 9 molecular images of the 1.8 MDa icosahedral core of pyruvate dehydrogenase. , 2004, Journal of structural biology.

[24]  R. Henderson,et al.  Optimal determination of particle orientation, absolute hand, and contrast loss in single-particle electron cryomicroscopy. , 2003, Journal of molecular biology.

[25]  Stefan Raunser,et al.  A syringe-like injection mechanism in Photorhabdus luminescens toxins , 2013, Nature.

[26]  Hstau Y Liao,et al.  Definition and estimation of resolution in single-particle reconstructions. , 2010, Structure.

[27]  Richard Henderson,et al.  Avoiding the pitfalls of single particle cryo-electron microscopy: Einstein from noise , 2013, Proceedings of the National Academy of Sciences.

[28]  Robert M Glaeser,et al.  Replication and validation of cryo-EM structures. , 2013, Journal of structural biology.

[29]  J Bernard Heymann,et al.  Bsoft: image processing and molecular modeling for electron microscopy. , 2007, Journal of structural biology.

[30]  G J Jensen,et al.  Alignment error envelopes for single particle analysis. , 2001, Journal of structural biology.

[31]  Marin van Heel,et al.  Finding trimeric HIV-1 envelope glycoproteins in random noise , 2013 .

[32]  Youdong Mao,et al.  Molecular architecture of the uncleaved HIV-1 envelope glycoprotein trimer , 2013, Proceedings of the National Academy of Sciences.

[33]  M. Heel,et al.  Exact filters for general geometry three dimensional reconstruction , 1986 .

[34]  D. Mastronarde,et al.  Data management challenges in three-dimensional EM , 2012, Nature Structural &Molecular Biology.

[35]  Youdong Mao,et al.  Reply to Subramaniam, van Heel, and Henderson: Validity of the cryo-electron microscopy structures of the HIV-1 envelope glycoprotein complex , 2013, Proceedings of the National Academy of Sciences.

[36]  M. Baker,et al.  Outcome of the First Electron Microscopy Validation Task Force Meeting , 2012, Structure.

[37]  Matthew L. Baker,et al.  Structural Changes in a Marine Podovirus Associated with Release of its Genome into Prochlorococcus , 2010, Nature Structural &Molecular Biology.

[38]  Joachim Frank,et al.  An approach to examining model dependence in EM reconstructions using cross-validation. , 2003, Journal of structural biology.

[39]  Shaoxia Chen,et al.  Prevention of overfitting in cryo-EM structure determination , 2012, Nature Methods.