A comparison between thermal-optical transmittance elemental carbon measured by different protocols in PM2.5 samples.

Although controlled procedures for the determination of carbonaceous fractions are of importance for any air quality measurements, currently no reference method for elemental carbon (EC) and organic carbon (OC) analysis is established yet in Europe. The implementation of the different thermal evolution protocols available in the literature, differing in temperature and duration of the heating ramps, affects the results and can result in a wide variation of EC and OC values. In this study three different protocols for thermal-optical-transmittance analysis of EC and OC were compared, namely He-870 (a variation of the NIOSH protocol), He-550 (a proxy of the IMPROVE protocol), and EUSAAR_2. Measurements were carried out on PM2.5 samples collected on Quartz fibre filters in three sites of different typology: urban background and urban traffic in Florence (Italy) and regional background in Livorno (Italy). The samples were analysed before and after a washing procedure to remove possible water-soluble organic compounds (WSOC), which may enhance the charring process, complicating the EC quantification. This study evidenced a very good agreement for TC measurement (at 2-3% level) and some discrepancies in EC measurement (up to 40%), as expected. WSOC and Pyrolitic Carbon (PyC) present a good correlation, independently of site typology, demonstrating that water soluble compound can be responsible of charring mechanism during the He phase.

[1]  Mar Viana,et al.  Toward a standardised thermal-optical protocol for measuring atmospheric organic and elemental carbon: the EUSAAR protocol , 2009 .

[2]  A. Petzold,et al.  Intercomparison of thermal and optical measurement methods for elemental carbon and black carbon at an urban location. , 2006, Environmental science & technology.

[3]  F. Lucarelli,et al.  Use of proton elastic scattering techniques to determine carbonaceous fractions in atmospheric aerosols collected on Teflon filters , 2015 .

[4]  A. Piazzalunga,et al.  Technical Note: On the effect of water-soluble compounds removal on EC quantification by TOT analysis in urban aerosol samples , 2011 .

[5]  Athanasios Katsoyiannis,et al.  One year intensive PM2.5 bound polycyclic aromatic hydrocarbons monitoring in the area of Tuscany, Italy. Concentrations, source understanding and implications. , 2012, Environmental pollution.

[6]  A. Robinson,et al.  Effect of Peak Inert-Mode Temperature on Elemental Carbon Measured Using Thermal-Optical Analysis , 2006 .

[7]  Judith C. Chow,et al.  Comparison of IMPROVE and NIOSH Carbon Measurements , 2001 .

[8]  R. Cary,et al.  Elemental Carbon-Based Method for Monitoring Occupational Exposures to Particulate Diesel Exhaust , 1996 .

[9]  T. Petäjä,et al.  Size distributions, sources and source areas of water-soluble organic carbon in urban background air , 2008 .

[10]  J. Chow,et al.  Results of the "Carbon Conference" International Aerosol Carbon Round Robin Test Stage I , 2001 .

[11]  Mar Viana,et al.  ECOC comparison exercise with identical thermal protocols after temperature offset correction – instrument diagnostics by in-depth evaluation of operational parameters , 2014 .

[12]  Yuan Cheng,et al.  Ambient organic carbon to elemental carbon ratios: influence of the thermal-optical temperature protocol and implications. , 2014, The Science of the total environment.

[13]  J. Conny,et al.  Optimizing Thermal-Optical Methods for Measuring Atmospheric Elemental (Black) Carbon: A Response Surface Study , 2003 .

[14]  Yong-liang Ma,et al.  Intercomparison of thermal-optical method with different temperature protocols: Implications from source samples and solvent extraction , 2012 .

[15]  Judith C. Chow,et al.  PM2.5 carbonate concentrations at regionally representative Interagency Monitoring of Protected Visual Environment sites , 2002 .

[16]  Hans Moosmüller,et al.  Equivalence of elemental carbon by thermal/optical reflectance and transmittance with different temperature protocols. , 2004, Environmental science & technology.

[17]  D. R. Worsnop,et al.  Evolution of Organic Aerosols in the Atmosphere , 2009, Science.

[18]  The use of levoglucosan for tracing biomass burning in PM₂.₅ samples in Tuscany (Italy). , 2012, Environmental pollution.

[19]  Eiliv Steinnes,et al.  Carbonaceous aerosols in Norwegian urban areas , 2009 .

[20]  L. Chen,et al.  Summary of Organic and Elemental Carbon/Black Carbon Analysis Methods and Intercomparisons , 2005 .

[21]  Alexandre Caseiro,et al.  Climatology of aerosol composition (organic versus inorganic) at nonurban sites on a west-east transect across Europe , 2007 .

[22]  Judith C. Chow,et al.  The dri thermal/optical reflectance carbon analysis system: description, evaluation and applications in U.S. Air quality studies , 1993 .

[23]  J. Putaud,et al.  INTERCOMP2000: the comparability of methods in use in Europe for measuring the carbon content of aerosol , 2004 .

[24]  L. Chen,et al.  Quality assurance and quality control for thermal/optical analysis of aerosol samples for organic and elemental carbon , 2011, Analytical and bioanalytical chemistry.

[25]  Paola Fermo,et al.  Carbonate measurements in PM10 near the marble quarries of Carrara (Italy) by infrared spectroscopy (FT-IR) and source apportionment by positive matrix factorization (PMF) , 2011 .