First results from a prototype dynamic attenuator system

The dynamic, piecewise-linear attenuator has been proposed as a concept which can shape the radiation flux incident on the patient. By reducing the signal to photon-rich measurements and increasing the signal to photon-starved measurements, the piecewise-linear attenuator has been shown to improve dynamic range, scatter, and variance and dose metrics in simulation. The piecewise-linear nature of the proposed attenuator has been hypothesized to mitigate artifacts at transitions by eliminating jump discontinuities in attenuator thickness at these points. We report the results of a prototype implementation of this concept. The attenuator was constructed using rapid prototyping technologies and was affixed to a tabletop x-ray system. Images of several sections of an anthropormophic pediatric phantom were produced and compared to those of the same system with uniform illumination. The thickness of the illuminated slab was limited by beam collimation and an analytic water beam hardening correction was used for both systems. Initial results are encouraging and show improved image quality, reduced dose and low artifact levels.

[1]  Steven Bartolac,et al.  Fluence field optimization for noise and dose objectives in CT. , 2011, Medical physics.

[2]  N. Pelc,et al.  Dose reduction using a dynamic, piecewise-linear attenuator. , 2014, Medical physics.

[3]  David Jaffray,et al.  Compensator models for fluence field modulated computed tomography. , 2013, Medical physics.

[4]  Timothy P. Szczykutowicz,et al.  Design of a digital beam attenuation system for computed tomography: part I. System design and simulation framework. , 2013, Medical physics.

[5]  Norbert J. Pelc,et al.  Optimized control of a dynamic, prepatient attenuator , 2013, Medical Imaging.

[6]  Jonathan Sperl,et al.  Computer-Assisted Scan Protocol and Reconstruction (CASPAR)—Reduction of Image Noise and Patient Dose , 2010, IEEE Transactions on Medical Imaging.

[7]  C. Mistretta,et al.  Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results. , 2013, Medical physics.

[8]  N. Pelc,et al.  An inverse-geometry volumetric CT system with a large-area scanned source: a feasibility study. , 2004, Medical physics.

[9]  C A Mistretta,et al.  Experimental realization of fluence field modulated CT using digital beam attenuation , 2014, Physics in medicine and biology.

[10]  N. Pelc,et al.  Control algorithms for dynamic attenuators. , 2014, Medical physics.

[11]  Taly Gilat Schmidt,et al.  A prototype table‐top inverse‐geometry volumetric CT system , 2006 .

[12]  N. Pelc,et al.  The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors , 2014, Physics in medicine and biology.

[13]  Norbert J Pelc,et al.  The feasibility of a piecewise-linear dynamic bowtie filter. , 2013, Medical physics.