[Adverse effects of continuous positive airway pressure therapy and its relation to the nose].

The main problem in the treatment of obstructive sleep apnea syndrome (OSAS) with nasal continuous airway pressure (nCPAP) is the lack of compliance. One of the most important reasons for no compliance is the adverse effects of this treatment. We analyse, prospectively, 182 patients treated with nCPAP in order to show the relationship between previous nasal problems and adverse effects of nCPAP. Sixty percent of the population developed one o more side effects. Of this group, 69% showed nasal septum deviation at first examination in front of 31% that did not showed this problem (p = 0.001). In the group of patients with nasal side effects we observed an increase of compliance in 80% of patients treated medically and in 89% of those treated by a septoplasty. We demonstrate that the adverse effects of nCPAP are related to previous nasal problems and, also, that treatment of those problems can achieve an increase in compliance to nCPAP therapy.

[1]  J. Maurer,et al.  Effect of Nasal Surgery on Sleep‐Related Breathing Disorders , 2002, The Laryngoscope.

[2]  T. Verse,et al.  Long-term results in the treatment of obstructive sleep apnea , 2000, European Archives of Oto-Rhino-Laryngology.

[3]  F Lofaso,et al.  Nasal obstruction as a risk factor for sleep apnoea syndrome. , 2000, The European respiratory journal.

[4]  W. Karrer,et al.  [Nasal CPAP therapy in obstructive sleep apnea syndrome: patient compliance]. , 2000, Schweizerische medizinische Wochenschrift.

[5]  A. Didier,et al.  [Results of 248 patients with sleep apnea syndrome treated by continuous positive pressure ventilation between 1990 and 1995. A study of compliance and outcome of the apnea-hypopnea index]. , 2000, Revue des maladies respiratoires.

[6]  C. Guilleminault,et al.  Surgery and Obstructive Sleep Apnea: Long-Term Clinical Outcomes , 2000, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[7]  D. Caldarelli,et al.  Effect of improved nasal breathing on obstructive sleep apnea , 2000, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[8]  J. Mullol Miret [Allergic rhinitis in the year 2000. Classification and up-dated treatment]. , 2000, Archivos de bronconeumologia.

[9]  A. Pietrzyk,et al.  [Compliance to treatment recommendations in patients with obstructive sleep apnea at least one year after diagnosis]. , 2000, Pneumonologia i alergologia polska.

[10]  E. Sforza,et al.  Effective compliance during the first 3 months of continuous positive airway pressure. A European prospective study of 121 patients. , 1999, American journal of respiratory and critical care medicine.

[11]  T. Seemungal,et al.  Adverse effects of nasal continuous positive airway pressure therapy in sleep apnoea syndrome , 1999, The Journal of Laryngology & Otology.

[12]  N. Mirza,et al.  The nasal airway and obstructed breathing during sleep. , 1999, Otolaryngologic clinics of North America.

[13]  P. Brander,et al.  Nasopharyngeal Symptoms in Patients with Obstructive Sleep Apnea Syndrome , 1999, Respiration.

[14]  T. Verse,et al.  [What are the side-effects of nocturnal continuous positive pressure ventilation (nCPAP) in patients with sleep apnea for the head-neck region?]. , 1999, Laryngo- rhino- otologie.

[15]  P. Brander,et al.  Nasopharyngeal symptoms and nasal continuous positive airway pressure therapy in obstructive sleep apnoea syndrome. , 1999, Acta oto-laryngologica.

[16]  J. Ware,et al.  Nasal Patency and the Effectiveness of Nasal Continuous Positive Air Pressure in Obstructive Sleep Apnea , 1998, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[17]  J. Paniagua-Soto,et al.  [Treatment of sleep apnea syndrome with CPAP: compliance with treatment, its efficacy and secondary effects]. , 1998, Revista de neurologia.

[18]  Y. Itasaka,et al.  Influence of nasal obstruction on obstructive sleep apnea. , 1998, Acta oto-laryngologica. Supplementum.

[19]  W. De Backer Non-CPAP treatment of obstructive sleep apnoea. , 1998, Monaldi archives for chest disease = Archivio Monaldi per le malattie del torace.

[20]  R. Siegert,et al.  [Therapy with nasal CPAP (continuous positive airway pressure) in patients with obstructive sleep apnea syndrome (OSAS). II: Side-effects of nCPAP therapy. Effect on long-term acceptance]. , 1997, Laryngo- rhino- otologie.

[21]  R. Grenman,et al.  Sleep disorders in patients with severe nasal obstruction due to septal deviation. , 1997, Acta oto-laryngologica. Supplementum.

[22]  P. Lévy,et al.  Clinical Investigations: Sleep and BreathingSide Effects of Nasal Continuous Positive Airway Pressure in Sleep Apnea Syndrome: Study of 193 Patients in Two French Sleep Centers , 1995 .

[23]  P. Ingrand,et al.  Predictive factors of long-term compliance with nasal continuous positive airway pressure treatment in sleep apnea syndrome. , 1994, Chest.

[24]  U. Fryksmark,et al.  Is there a relationship between the degree of nasal obstruction and snoring? , 1993, Clinical otolaryngology and allied sciences.

[25]  J. Conway,et al.  Treatment of obstructive sleep apnea with nasal continuous positive airway pressure. Patient compliance, perception of benefits, and side effects. , 1992, The American review of respiratory disease.

[26]  J. Weil,et al.  Disturbed sleep and prolonged apnea during nasal obstruction in normal men. , 2015, The American review of respiratory disease.