Plastic fibres as the only reinforcement for flat suspended slabs: Experimental investigation and numerical simulation

Abstract This paper focuses on the study of the structural response of hyperstatic concrete flat suspended slabs reinforced only with structural plastic macro-fibres. First, the experimental program is described and then the results obtained are presented. The slabs tested maintained a high load level after cracking showing a ductile behaviour with great stress redistribution capacity. Next, the tests were simulated by means of a finite element software with constitutive models according to the specifications of RILEM and the Spanish Structural Concrete Code (EHE). The numerical results in terms of load/mid-span deflection were compared with the experimental results. The predictions provided by the codes and guideline models clearly overestimated the experimental results, which suggests the need to review the constitutive models used for plastic fibre-reinforced concrete.

[1]  Climent Molins,et al.  Double Punch Test to control the energy dissipation in tension of FRC (Barcelona test) , 2009 .

[2]  L. Turanli,et al.  Comparative evaluation of steel mesh, steel fibre and high-performance polypropylene fibre reinforced shotcrete in panel test , 2004 .

[3]  David A Lange,et al.  Effect of synthetic fibers on structural behavior of concrete slabs-on-ground , 2006 .

[4]  D. Waldmann,et al.  Steel fibers as only reinforcement for flat slab construction – Experimental investigation and design , 2012 .

[5]  Antonio Aguado,et al.  Application of constitutive models in European codes to RC–FRC , 2013 .

[6]  Lucie Vandewalle,et al.  Dispersion of the mechanical properties of FRC investigated by different bending tests , 2008 .

[7]  Albert de la Fuente,et al.  New analytical model to generalize the Barcelona Test using axial displacement , 2013 .

[8]  Antonio Aguado de Cea,et al.  Análisis comparativo de los modelos constitutivos del hormigón reforzado con fibras , 2010 .

[9]  Dubravka Bjegović,et al.  Ultra High Performance Fibre-Reinforced Concretes-Interim Recommendations , 2004 .

[10]  P. Serna,et al.  Structural cast-in-place SFRC: technology, control criteria and recent applications in spain , 2009 .

[11]  Lucie Vandewalle,et al.  RILEM TC162-TDF : Test and Design Methdos for Steel Fibre Reinforced Concrete : Design of steel fibre reinforced concrete using the sigma-w-method : principles and applications , 2002 .

[12]  Amir M. Alani,et al.  Mechanical properties of a large scale synthetic fibre reinforced concrete ground slab , 2013 .

[13]  P. Rossi,et al.  Analysis and Design of Steel Fiber Reinforced Concrete Beams , 1997 .

[14]  Z. Bažant,et al.  Crack band theory for fracture of concrete , 1983 .

[15]  Joost C. Walraven,et al.  High performance fiber reinforced concrete: progress in knowledge and design codes , 2009 .

[16]  Filipe Laranjeira de Oliveira Design-oriented constitutive model for steel fiber reinforced concrete , 2010 .

[17]  M. Prisco,et al.  Structural applications of steel fibre reinforcement concrete , 2000 .

[18]  Antonio Aguado,et al.  Inductive method for assessing the amount and orientation of steel fibers in concrete , 2012 .

[19]  W. C. Schnobrich,et al.  Finite Element Analysis of Reinforced Concrete , 1973 .

[20]  Alberto Meda,et al.  Steel Fiber Concrete Slabs on Ground: A Structural Matter , 2006 .

[21]  Steen Krenk,et al.  Analytical Model for Fictitious Crack Propagation in Concrete Beams , 1995 .

[22]  Antonio Aguado,et al.  Cracking behavior of FRC slabs with traditional reinforcement , 2012 .

[23]  Joaquim Figueiras,et al.  Experimental behaviour of fibre concrete slabs on soil , 1998 .

[24]  Knud Winstrup Johansen,et al.  Yield-line Formulae for Slabs , 1972 .

[25]  T. Le,et al.  Flexural performance of fibre reinforced concrete made with steel and synthetic fibres , 2012 .

[26]  A W Beeby,et al.  CONCISE EUROCODE FOR THE DESIGN OF CONCRETE BUILDINGS. BASED ON BSI PUBLICATION DD ENV 1992-1-1: 1992. EUROCODE 2: DESIGN OF CONCRETE STRUCTURES. PART 1: GENERAL RULES AND RULES FOR BUILDINGS , 1993 .

[27]  V Cervenka,et al.  SIMULATING A RESPONSE , 2000 .

[28]  Lucie Vandewalle,et al.  RILEM TC 162-TDF: Test and design methods for steel fibre reinforced concrete' - sigma-epsilon-design method - Final Recommendation , 2003 .

[29]  Henrik Stang,et al.  New production processes, materials and calculation techniques for fiber reinforced concrete pipes , 1997 .

[30]  Bernardino Chiaia,et al.  Combining fiber-reinforced concrete with traditional reinforcement in tunnel linings , 2009 .

[31]  Fatih Altun,et al.  A comparative experimental investigation of concrete, reinforced-concrete and steel-fibre concrete pipes under three-edge-bearing test , 2007 .

[32]  Lucie Vandewalle,et al.  Fibre reinforced concrete: new design perspectives , 2009 .

[33]  Habibollah Akbar,et al.  Cracking in Reinforced Concrete Analysis , 1984 .

[34]  Lucie Vandewalle,et al.  Cracking behaviour of concrete beams reinforced with a combination of ordinary reinforcement and steel fibers , 2000 .

[35]  Claudio Mazzotti,et al.  Post-cracking behaviour of steel and macro-synthetic fibre-reinforced concretes , 2011 .

[36]  Albert de la Fuente,et al.  Experiences in Barcelona with the use of fibres in segmental linings , 2012 .