Numerical computation of blood hemodynamic through constricted human left coronary artery: Pulsatile simulations

BACKGROUND AND OBJECTIVE The accumulation of plaque in the coronary artery of the human heart restricts the path of blood flow in that region and leads to Coronary Artery Disease. This study's goal is to present the pulsatile blood flow conduct through four different levels of constrictions, i.e., healthy, 25%, 50%, and 75% in human left coronary arteries. METHODS Using CT scan data of a healthy person, the two-dimensional coronary model is constructed. A non-Newtonian Carreau model is used to study the maximum flow velocity, streamline effect, and maximum Wall Shear Stress at the respective constricted areas over the entire cardiac cycle. Finite Volume Method is executed for solving the governing equations. The fluctuating Wall Shear Stress (WSS) at different levels was assessed using Computational Fluid Dynamics (CFD). RESULTS The comparative study of the diseased arteries showcases that at the systolic phase, the 75% blocked artery attains the maximum velocity of 0.14 m/s and 0.53 m/s at t=0.005 s and t=0.115 s, respectively. While the maximum velocity takes a significant drop at t=0.23 s and t=0.345 s, this marks the diastolic phase. The streamline contour showcased the blood flow conduct at different phases of the cardiac cycle. At the peak systolic phase, a dense flow separation was observed near the blocked regions. It highlights the disturbed flow in that particular region. The most severely diseased artery acquires the maximum WSS of 18.81 Pa at the peak systolic phase, i.e., at t=0.115 s. CONCLUSIONS The computational study of the hemodynamic parameters can aid in the early anticipation of the degree of the severity of the diseased arteries. This study, in a way, could benefit doctors/surgeons to plan an early treatment/surgery on the grounds of the severity of the disease. Thus, a before time prognosis could restrain the number of deaths caused due to Coronary Artery Disease.

[1]  Yan Ding,et al.  Comparative analysis of pulsatile and steady flow on arterial mass transport , 2014 .

[2]  Richard S.C. Cobbold,et al.  Pulsatile flow through constricted tubes: an experimental investigation using photochromic tracer methods , 1989, Journal of Fluid Mechanics.

[3]  Barbara M. Johnston,et al.  Non-Newtonian blood flow in human right coronary arteries: transient simulations. , 2006, Journal of biomechanics.

[4]  P. Stone,et al.  Effects of curvature and stenosis-like narrowing on wall shear stress in a coronary artery model with phasic flow. , 1997, Computers and biomedical research, an international journal.

[5]  S. Tabakova,et al.  Carreau model for oscillatory blood flow in a tube , 2014 .

[6]  Priya Ranjan,et al.  Modelling of Blood Flow in Stenosed Arteries , 2017 .

[7]  R. Pélissier,et al.  Experimental analysis of unsteady flows through a stenosis. , 1997, Journal of biomechanics.

[8]  J. Buchanan,et al.  Rheological effects on pulsatile hemodynamics in a stenosed tube , 2000 .

[9]  H V Anderson,et al.  Coronary artery flow velocity is related to lumen area and regional left ventricular mass. , 2000, Circulation.

[10]  R. Lutz,et al.  Comparison of steady and pulsatile flow in a double branching arterial model. , 1983, Journal of biomechanics.

[11]  Luca Mainardi,et al.  A framework for computational fluid dynamic analyses of patient-specific stented coronary arteries from optical coherence tomography images. , 2017, Medical engineering & physics.

[12]  N Karcanias,et al.  Vortex formation and recirculation zones in left anterior descending artery stenoses: computational fluid dynamics analysis , 2010, Physics in medicine and biology.

[13]  Pramod M. Padole,et al.  CFD Analysis of Pulsatile Flow and Non-NewtonianBehavior of Blood in Arteries , 2015 .

[14]  Pengcheng Xu,et al.  The Impact of the Geometric Characteristics on the Hemodynamics in the Stenotic Coronary Artery , 2016, PloS one.

[15]  Zhonghua Sun,et al.  Hemodynamic impacts of various types of stenosis in the left coronary artery bifurcation: a patient-specific analysis. , 2013, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[16]  M. Serdar Celebi,et al.  Analysis of the effects of different pulsatile inlet profiles on the hemodynamical properties of blood flow in patient specific carotid artery with stenosis , 2013, Comput. Biol. Medicine.

[17]  A. Nagar,et al.  Mathematical Analysis of Carreau Fluid Model for Blood Flow In Tapered Constricted Arteries , 2018 .

[18]  A. Zagatina,et al.  Role of Coronary Flow Velocity in Predicting Adverse Outcome in Clinical Practice. , 2018, Ultrasound in medicine & biology.

[19]  Barbara M. Johnston,et al.  Non-Newtonian blood flow in human right coronary arteries: steady state simulations. , 2004, Journal of biomechanics.

[20]  J. Blažek Chapter 3 – Principles of Solution of the Governing Equations , 2005 .

[21]  Mehrzad Shams,et al.  Effects of different non-Newtonian models on unsteady blood flow hemodynamics in patient-specific arterial models with in-vivo validation , 2019, Comput. Methods Programs Biomed..

[22]  Wei Yin,et al.  Effect of geometrical assumptions on numerical modeling of coronary blood flow under normal and disease conditions. , 2010, Journal of biomechanical engineering.

[23]  Tzu-Ching Shih,et al.  Computational fluid dynamics with application of different theoretical flow models for the evaluation of coronary artery stenosis on CT angiography: comparison with invasive fractional flow reserve , 2016 .

[24]  S. Corney,et al.  Cyclic flow patterns in human coronary arteries , 2001, Computers in Cardiology 2001. Vol.28 (Cat. No.01CH37287).

[25]  A. Zander,et al.  Three-dimensional biomechanics of coronary arteries , 2018, International Journal of Engineering Science.

[26]  Thong-See Lee Numerical studies of fluid flow through tubes with double constrictions , 1990 .

[27]  T. Tokushima,et al.  Phasic coronary artery flow velocity determined by Doppler flowmeter catheter in aortic stenosis and aortic regurgitation. , 1988, The American journal of cardiology.

[28]  J. M. Siegel,et al.  A scaling law for wall shear rate through an arterial stenosis. , 1994, Journal of biomechanical engineering.

[29]  M. Darwish,et al.  The Finite Volume Method in Computational Fluid Dynamics: An Advanced Introduction with OpenFOAM® and Matlab , 2015 .

[30]  M. Saidi,et al.  Primary stenosis progression versus secondary stenosis formation in the left coronary bifurcation: A mechanical point of view , 2019, Biocybernetics and Biomedical Engineering.

[31]  P. Bagchi,et al.  Flow of Red Blood Cells in Stenosed Microvessels , 2016, Scientific Reports.

[32]  S. Corney,et al.  Construction of realistic branched, three-dimensional arteries suitable for computational modelling of flow , 2004, Medical and Biological Engineering and Computing.

[33]  D. Mandal,et al.  Study on the effect of steady, simple pulsatile and physiological pulsatile flows through a stenosed artery , 2014 .

[34]  V Deplano,et al.  Experimental and numerical study of pulsatile flows through stenosis: wall shear stress analysis. , 1999, Journal of biomechanics.

[35]  Luoding Zhu,et al.  Simulation of a pulsatile non-Newtonian flow past a stenosed 2D artery with atherosclerosis , 2013, Comput. Biol. Medicine.

[36]  Z. Mimouni The Rheological Behavior of Human Blood—Comparison of Two Models , 2016 .

[37]  L. Kritharides,et al.  The relationship between coronary lesion characteristics and pathologic shear in human coronary arteries , 2018, Clinical biomechanics.

[38]  Fergal J Boyle,et al.  A full-range, multi-variable, CFD-based methodology to identify abnormal near-wall hemodynamics in a stented coronary artery. , 2010, Biorheology.