MRI RF Array Decoupling Method With Magnetic Wall Distributed Filters

Multi-channel radio-frequency (RF) transmit coil arrays have been developed to mitigate many of the RF challenges associated with ultra-high field ( ≥ 7T) magnetic resonance imaging (MRI). These arrays can be used for parallel RF transmission to produce spatially tailored RF excitation over the field of view. However, the realization of such arrays remains a challenge due to significant reactive interaction between the array coils, i.e., mutual coupling. In this paper, a novel bandstop filter (“magnetic wall”) is used in an MRI RF transmit array to decouple individual coils. The proposed decoupling method is inspired by periodic resonator designs commonly used in frequency selective surfaces and is used as a distributed RF filter to suppress the transmission of RF energy between coils in an array. The decoupling of the magnetic wall (MW) is analyzed in terms of equivalent circuits that include terms for both magnetic and electric coupling for an arbitrary number of MW resonant conductors. Both frequency-and time-domain full-wave simulations were performed to analyze a specific MW structure. The performance of the proposed method is experimentally validated for both first-order coupling and higher-order coupling with a three-coil 7T array setup. Analysis and measurements confirm that the rejection band of the MW can be tuned to provide high isolation in the presence of cross coupling between RF array coils.

[1]  I. Bar-on,et al.  Quantitative Edge Cross-Section Angle Impact on Conductor Loss , 2010, IEEE Transactions on Components and Packaging Technologies.

[2]  Jiasheng Hong,et al.  Couplings of microstrip square open-loop resonators for cross-coupled planar microwave filters , 1996 .

[3]  J. Bonache,et al.  Equivalent-circuit models for split-ring resonators and complementary split-ring resonators coupled to planar transmission lines , 2005, IEEE Transactions on Microwave Theory and Techniques.

[4]  Steen Moeller,et al.  A 32‐channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla , 2010, Magnetic resonance in medicine.

[5]  Yi Wang,et al.  Design of multiple-passband filters using coupling matrix optimisation , 2012 .

[6]  D. Hoult Sensitivity and Power Deposition in a High‐Field Imaging Experiment , 2000, Journal of magnetic resonance imaging : JMRI.

[7]  Stephen P. Boyd,et al.  Simple accurate expressions for planar spiral inductances , 1999, IEEE J. Solid State Circuits.

[8]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[9]  E. Adalsteinsson,et al.  Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels , 2008, Magnetic resonance in medicine.

[10]  Ekmel Ozbay,et al.  Miniaturized negative permeability materials , 2007 .

[11]  Yudong Zhu,et al.  Parallel excitation with an array of transmit coils , 2004, Magnetic resonance in medicine.

[12]  Jerzy Julian Michalski,et al.  Coupling Matrix Synthesis by Optimization with Cost Function Based on Daubechies D4 Wavelet Transform , 2012 .

[13]  Steen Moeller,et al.  A geometrically adjustable 16‐channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla , 2008, Magnetic resonance in medicine.

[14]  F. Medina,et al.  Spatial Angular Filtering by FSSs Made of Chains of Interconnected SRRs and CSRRs , 2013, IEEE Microwave and Wireless Components Letters.

[15]  A. Toscano,et al.  Equivalent-Circuit Models for the Design of Metamaterials Based on Artificial Magnetic Inclusions , 2007, IEEE Transactions on Microwave Theory and Techniques.

[16]  D. I. Hoult,et al.  Overcoming high-field RF problems with non-magnetic Cartesian feedback transceivers , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[17]  Lawrence L. Wald,et al.  Design considerations and coil comparisons for 7 T brain imaging , 2005 .

[18]  Michael J. Lancaster,et al.  Synthesis of multiple output coupled resonator circuits using coupling matrix optimisation , 2011 .

[19]  Klaus Scheffler,et al.  A 16‐channel dual‐row transmit array in combination with a 31‐element receive array for human brain imaging at 9.4 T , 2014, Magnetic resonance in medicine.

[20]  Jian Zhang,et al.  Sharp-rejection low-pass filter with controllable transmission zero using complementary split ring resonators (csrrs) , 2007 .

[21]  Vivek K. Goyal,et al.  Sparsity-Enforced Slice-Selective MRI RF Excitation Pulse Design , 2008, IEEE Transactions on Medical Imaging.

[22]  D I Hoult,et al.  The signal-to-noise ratio of the nuclear magnetic resonance experiment. 1976. , 1976, Journal of magnetic resonance.

[23]  Kyle M Gilbert,et al.  A radiofrequency coil to facilitate B  1+ shimming and parallel imaging acceleration in three dimensions at 7 T , 2011, NMR in biomedicine.

[24]  D. Hoult,et al.  The NMR multi-transmit phased array: a Cartesian feedback approach. , 2004, Journal of magnetic resonance.

[26]  Ke Feng,et al.  Reducing SAR in parallel excitation using variable-density spirals: a simulation-based study. , 2008, Magnetic resonance imaging.

[27]  A. Toscano,et al.  Design of Spiral and Multiple Split-Ring Resonators for the Realization of Miniaturized Metamaterial Samples , 2007, IEEE Transactions on Antennas and Propagation.

[28]  Klaas P Pruessmann,et al.  Optimal design of multiple‐channel RF pulses under strict power and SAR constraints , 2010, Magnetic resonance in medicine.

[29]  Douglas C Noll,et al.  Reduction of transmitter B1 inhomogeneity with transmit SENSE slice‐select pulses , 2007, Magnetic resonance in medicine.

[30]  J. Eichmann,et al.  Active digital decoupling for multi-channel transmit MRI Systems , 2007 .

[31]  Ben A. Munk,et al.  Frequency Selective Surfaces: Theory and Design , 2000 .

[32]  P. Börnert,et al.  Transmit SENSE , 2003, Magnetic resonance in medicine.

[33]  A. Toscano,et al.  Efficient Modeling of the Crosstalk Between Two Coupled Microstrip Lines Over Nonconventional Materials Using an Hybrid Technique , 2008, IEEE Transactions on Magnetics.

[34]  Ravi S. Menon,et al.  Design of a Parallel Transmit Head Coil at 7T With Magnetic Wall Distributed Filters , 2015, IEEE Transactions on Medical Imaging.