A feasibility study to measure magnetocardiography (MCG) in unshielded environment using first order gradiometer

Abstract Measurement of weak magnetic fields generated by the electrical activity of the heart is known as magnetocardiogram (MCG). MCG is usually measured using highly sensitive Superconducting Quantum Interference Devices (SQUIDs) inside a Magnetically Shielded Room (MSR). Since MCG signals have a relatively higher amplitude, researchers have attempted to measure MCG in poorly shielded or even in unshielded environments using higher order gradiometers to cancel excess noise. However, they also attenuate signals of interest, especially, those originating from deeper sources. Here, we report a feasibility study to examine the suitability of use of First Order Gradiometers (FOG) to measure MCG in a totally unshielded environment. Usually, conventional noise reduction methods involve averaging of a large number of cardiac cycles aligned by R-peak time instants derived from a simultaneously recorded electrocardiogram (ECG). In addition to this, here we employ a novel noise reduction approach based on Ensemble Empirical Mode Decomposition (EEMD) technique to manage the fall in Signal to Noise Ratio (SNR) in unshielded environment. The study demonstrated an improvement in SNR of about 18 dB in unshielded setup measured using a four channel low TC-DC SQUID system when tested on eight healthy subjects and one subject with a known cardiac dysfunction. MCG traces were measured across different locations on the thorax and the spatial distribution of cardiac magnetic field is visualized using magnetic field maps. The resulting data have been critically evaluated and compared with those derived from MCG measurements made inside the MSR and encourages its clinical utility.

[1]  Mariyappa Narayanan,et al.  Enhancing the Reliability in the Noninvasive Measurement of the His Bundle Magnetic Field Using a Novel Signal Averaging Methodology , 2012, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc.

[2]  Y. H. Lee,et al.  Averaging algorithm based on data statistics in magnetocardiography. , 2004, Neurology & clinical neurophysiology : NCN.

[3]  X. Kong,et al.  Multi-Channel Magnetocardiogardiography System Based on Low-Tc SQUIDs in an Unshielded Environment , 2012 .

[4]  Riccardo Fenici,et al.  Magnetocardiographic study of patients with right and left bundle branch blocks , 2007 .

[5]  C. Kang,et al.  Measurement of MCG in Unshielded Environment Using a Second-Order SQUID Gradiometer , 2009, IEEE Transactions on Magnetics.

[6]  W. Shimizu,et al.  Visualization of three-dimensional cardiac electrical excitation using standard heart model and anterior and posterior magnetocardiogram , 2006, The International Journal of Cardiovascular Imaging.

[7]  Nick Pawlowski,et al.  A portable diagnostic device for cardiac magnetic field mapping , 2016, 1609.05771.

[8]  A. C. Bruno,et al.  A symmetric third order gradiometer without external balancing or magnetocardiography , 1983 .

[9]  Rajesh Patel,et al.  Designing a Low-Cost, Single-Supply ECG System for Suppression of Movement Artifact from Contaminated Magnetocardiogram , 2018, SLAS technology.

[10]  R. Fenici,et al.  Clinical multichannel MCG in unshielded hospital environment. , 2004, Neurology & clinical neurophysiology : NCN.

[11]  Yi Zhang,et al.  SQUID gradiometry for magnetocardiography using different noise cancellation techniques , 2001 .

[12]  Rajesh Patel,et al.  Effective Extraction of Visual Event-Related Pattern by Combining Template Matching With Ensemble Empirical Mode Decomposition , 2017, IEEE Sensors Journal.

[13]  H. Horigome,et al.  Demonstration of Unshielded Fetal Magnetocardiography System Using Two-Dimensional Gradiometers , 2008, IEEE Transactions on Applied Superconductivity.

[14]  Rajesh Patel,et al.  Denoising of multichannel MCG data by the combination of EEMD and ICA and its effect on the pseudo current density maps , 2015, Biomed. Signal Process. Control..

[15]  S Comani,et al.  Optimal filter design for shielded and unshielded ambient noise reduction in fetal magnetocardiography , 2005, Physics in medicine and biology.

[17]  Kamal Alameh,et al.  NOISE CANCELLATION IN UNSHIELDED MAGNETOCARDIOGRAPHY BASED ON LEAST-MEAN-SQUARED ALGORITHM AND GENETIC ALGORITHM , 2013 .

[18]  H. Koch SQUID magnetocardiography: status and perspectives , 2001 .

[19]  T. S. Radhakrishnan,et al.  Baseline drift removal and denoising of MCG data using EEMD: role of noise amplitude and the thresholding effect. , 2014, Medical engineering & physics.

[20]  R. Fagaly Superconducting quantum interference device instruments and applications , 2006 .

[21]  N. Huang,et al.  The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis , 1998, Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[22]  K. Kim,et al.  Multichannel MCG Systems with Optimum Combinations of Pickup Coils and Shielded Rooms , 2007, 2007 Joint Meeting of the 6th International Symposium on Noninvasive Functional Source Imaging of the Brain and Heart and the International Conference on Functional Biomedical Imaging.

[23]  R. Fenici,et al.  Unshielded magnetocardiography: Repeatability and reproducibility of automatically estimated ventricular repolarization parameters in 204 healthy subjects , 2018, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc.

[24]  Riccardo Fenici,et al.  Multichannel mapping of fetal magnetocardiogram in an unshielded hospital setting , 2005, Prenatal diagnosis.

[25]  In-Seon Kim,et al.  Usefulness of magnetocardiogram to detect unstable angina pectoris and non-ST elevation myocardial infarction. , 2009, The American journal of cardiology.

[26]  Herbert Bousack,et al.  Second-order, high-temperature superconducting gradiometer for magnetocardiography in unshielded environment , 2000 .

[27]  Valentina Tiporlini,et al.  Magnetocardiography in unshielded environment based on optical magnetometry and adaptive noise cancellation , 2013 .

[28]  Baldev Raj,et al.  SQUID-based measurement of biomagnetic fields , 2010 .

[29]  Shu-Hsien Liao,et al.  High-Tc SQUID gradiometer system for magnetocardiography in an unshielded environment , 2003 .

[30]  Norden E. Huang,et al.  Ensemble Empirical Mode Decomposition: a Noise-Assisted Data Analysis Method , 2009, Adv. Data Sci. Adapt. Anal..