Depth perception of stereo overlays in image-guided surgery

See-through augmented reality (AR) systems for image-guided surgery merge volume rendered MRI/CT data directly with the surgeon’s view of the patient during surgery. Research has so far focused on optimizing the technique of aligning and registering the computer-generated anatomical images with the patient’s anatomy during surgery. We have previously developed a registration and calibration method that allows alignment of the virtual and real anatomy to ~1mm accuracy. Recently we have been investigating the accuracy with which observers can interpret the combined visual information presented with an optical see-through AR system. We found that depth perception of a virtual image presented in stereo below a physical surface was misperceived compared to viewing the target in the absence of a surface. Observers overestimated depth for a target 0-2cm below the surface and underestimated the depth for all other presentation depths. The perceptual error could be reduced, but not eliminated, when a virtual rendering of the physical surface was displayed simultaneously with the virtual image. The findings suggest that misperception is due either to accommodation conflict between the physical surface and the projected AR image, or the lack of correct occlusion between the virtual and real surfaces.

[1]  Zijiang J. He,et al.  Terrain influences the accurate judgement of distance , 1998, Nature.

[2]  Wolfgang Birkfellner,et al.  A modular software system for computer-aided surgery and its first application in oral implantology , 2000, IEEE Transactions on Medical Imaging.

[3]  Michael Schnaider,et al.  Medarpa--a medical augmented reality system for minimal-invasive interventions. , 2003, Studies in health technology and informatics.

[4]  Leila Eadie,et al.  The Limits of Transparent Depth Perception with Restricted Field of View: Application in an Augmented Reality Surgical Microscope , 2001 .

[5]  Hideo Kusaka,et al.  Psychophysical Analysis of the “Sensation of Reality” Induced by a Visual Wide-Field Display , 1980 .

[6]  William E. Lorensen,et al.  The visualization toolkit (2nd ed.): an object-oriented approach to 3D graphics , 1998 .

[7]  Stephen R. Ellis,et al.  Localization of Virtual Objects in the Near Visual Field , 1998, Hum. Factors.

[8]  Michael S. Landy,et al.  A Statistical Framework for Robust Fusion of Depth Information , 1989, Other Conferences.

[9]  R. Jacobs What determines visual cue reliability? , 2002, Trends in Cognitive Sciences.

[10]  R. P. Gaston,et al.  A System for Microscope-Assisted Guided Interventions , 2000, Stereotactic and Functional Neurosurgery.

[11]  J T Todd,et al.  The perception of stereoscopic transparency , 1988, Perception & psychophysics.

[12]  David J. Hawkes,et al.  Design and evaluation of a system for microscope-assisted guided interventions (MAGI) , 2000 .

[13]  John P. Frisby,et al.  Interaction of Stereo, Texture Cues in the Shape Perception Dimensional Ridges , 1993 .

[14]  Dario L. Ringach,et al.  Binocular eye movements caused by the perception of three-Dimensional structure from motion , 1996, Vision Research.

[15]  H Iseki,et al.  Volumegraph (overlaid three-dimensional image-guided navigation). Clinical application of augmented reality in neurosurgery. , 1997, Stereotactic and functional neurosurgery.

[16]  R A Robb,et al.  Analyze: a comprehensive, operator-interactive software package for multidimensional medical image display and analysis. , 1989, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[17]  Hiroshi Ishii,et al.  Transparent layered user interfaces: an evaluation of a display design to enhance focused and divided attention , 1995, CHI '95.

[18]  Zijiang J. He,et al.  Distance determined by the angular declination below the horizon , 2001, Nature.

[19]  D F Ormerod,et al.  Use of an augmented reality display of patient monitoring data to enhance anesthesiologists' response to abnormal clinical events. , 2003, Studies in health technology and informatics.

[20]  David J. Hawkes,et al.  Stereo Augmented Reality in the Surgical Microscope , 2000, Presence: Teleoperators & Virtual Environments.