Principal component analysis as a method to facilitate fast detection of transient-evoked otoacoustic emissions

Transient-evoked otoacoustic emissions (TEOAE) are acoustic signals coming from the inner ear (outer hair cells of the cochlea) after acoustic stimulation by clicks. They can be used to investigate the status of the peripheral hearing system. Some of their potential applications (e.g., their use as a tool in newborn hearing screening programs) are deeply related to the duration of each recording session. This duration can be strongly reduced by applying a principal component analysis approach to a set of TEOAE recorded from the same ear at different stimulus levels averaging only a few sweeps (a maximum of 100 versus the classical 260). The PCA approach is shown to be able to enhance the signal-to-noise ratio and, in turn, to allow a correct detection of the responses. Results of the application of this approach in comparison with responses recorded from the same subjects with the classical technique are shown.

[1]  D. Kemp Stimulated acoustic emissions from within the human auditory system. , 1978, The Journal of the Acoustical Society of America.

[2]  Daniel S. Ruchkin,et al.  Principles of Neurobiological Signal Analysis , 1976 .

[3]  M. Lutman,et al.  Reliable identification of click-evoked otoacoustic emissions using signal-processing techniques. , 1993, British journal of audiology.

[4]  P. Ravazzani,et al.  Evoked otoacoustic emissions: nonlinearities and response interpretation , 1993, IEEE Transactions on Biomedical Engineering.

[5]  Ferdinando Grandori,et al.  European Consensus Statement on Neonatal Hearing Screening , 1998, The Journal of Laryngology & Otology.

[6]  R Probst,et al.  A review of otoacoustic emissions. , 1991, The Journal of the Acoustical Society of America.

[7]  M. Turk,et al.  Eigenfaces for Recognition , 1991, Journal of Cognitive Neuroscience.

[8]  G. Tognola,et al.  Two-dimensional filter to facilitate detection of transient-evoked otoacoustic emissions , 1998, IEEE Transactions on Biomedical Engineering.

[9]  F Grandori,et al.  European Consensus Statement on Neonatal Hearing Screening. Finalised at the European Consensus Development Conference on Neonatal Hearing Screening, 15-16 May 1998, Milan. , 1998, International journal of pediatric otorhinolaryngology.

[10]  J. Mocks,et al.  Topographic components model for event-related potentials and some biophysical considerations , 1988, IEEE Transactions on Biomedical Engineering.

[11]  S Yamamoto,et al.  Quantitative gait evaluation of hip diseases using principal component analysis. , 1983, Journal of biomechanics.